CEREPAK HELIFORM SHD180520Recalls & reported problems

Cerenovus, Inc. · CEREPAK HELIFORM XL Detachable Coil Delivery System Length - 190 cm Coil Diameter - 5 mm Coil Length - 20 cm · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886704083481), received between Dec 4, 2024 and Dec 4, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Separation Failure” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Oct 2, 2025Open, Classified

    Detachable coils system may fail to detach, which could result in hemorrhagic and ischemic stroke, procedural delays, or the need for additional surgical intervention.

    Z-0434-2026 · Root cause: Under Investigation by firm · FDA record ↗

Most reported problems

Device problems

  • Separation Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 4, 2024Separation Failure; Separation Failure

    THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN ENDOVASCULAR EMBOLIZATION PROCEDURE TO RETREAT AN ANEURYSM DUE TO RESIDUAL FILLING ON FOLLOW-UP ANGIOGRAPHY, THE MICROCATHETER WAS NAVIGATED INTO THE ANEURYSM AND A 5MM X 20CM CEREPAK HELIFORM XL (SHD180520 / 31228059) WAS INTRODUCED. AN ATTEMPT TO DETACH THE COIL WAS MADE WITH THE DETACHMENT HANDLE (MDH1 / 102109430) WIRE WITH SLOW ACTUATION TO TRANSLATE THE PULL WIRE. THE CEREPAK HELIFORM COIL DID NOT DETACH, AND THE PULL WIRE WAS NOT VISIBLY ELONGATED. DETACHMENT WAS ATTEMPTED AGAIN WITH THE DETACHMENT HANDLE AND THE PULL WIRE WAS CONFIRMED TO BE ELONGATED POST-ACTUATION. WHEN THE COIL PUSHER WAS BEING REMOVED, IT WAS NOTED THAT THE COIL WAS NOT DETACHED. THE PHYSICIAN SWITCHED TO THE MANUAL BREAK METHOD. THE OUTER TUBE WAS SNAPPED AT THE SCORE MARK WITH THE PULL WIRE STILL INTACT. LIGHT TENSION WAS USED TO ACTUATE BUT THE PULL WIRE STRETCHED. THE COIL WAS NOT DETACHED AND WAS REMOVED FROM THE PATIENT. THE PROCEDURE WAS COMPLETED USING TARGET COILS (STRYKER). THE PROCEDURE WAS DELAYED BY 10 MINUTES, BUT IT WAS SUCCESSFULLY COMPLETED. THERE WAS NO REPORT OF ANY NEGATIVE PATIENT IMPACT. ON 25-NOV-2024, ADDITIONAL INFORMATION WAS

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20849033 ↗

Other DEVICE, NEUROVASCULAR EMBOLIZATION devices

All DEVICE, NEUROVASCULAR EMBOLIZATION devices →