CEREPAK HELIFORM SHD181445Recalls & reported problems

Cerenovus, Inc. · CEREPAK HELIFORM XL Detachable Coil Delivery System Length - 190 cm Coil Diameter - 14 mm Coil Length - 45 cm · Class 2 · Implant

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886704083559), received between Dec 28, 2023 and Dec 28, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Separation Failure” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Oct 2, 2025Open, Classified

    Detachable coils system may fail to detach, which could result in hemorrhagic and ischemic stroke, procedural delays, or the need for additional surgical intervention.

    Z-0434-2026 · Root cause: Under Investigation by firm · FDA record ↗

Most reported problems

Device problems

  • Separation Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 28, 2023Separation Failure; Separation Failure

    THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING THE COIL EMBOLIZATION PROCEDURE TARGETING A LEFT PERI-OPHTHALMIC ANEURYSM WITH THE CEREPAK COIL SYSTEM, THE FIRST COIL INTRODUCED WAS DETACHED WITHOUT ISSUE. THE SECOND COIL WAS A 14MM X 45CM CEREPAK HELIFORM XL (SHD181445 / 31154801) WAS INTRODUCED INTO THE ANEURYSM WITHOUT ISSUE. THE PHYSICIAN FOLLOWED TRAINING PROTOCOL BUT THE COIL WOULD NOT DETACH. THE COIL WAS REMOVED SAFELY; IT HAS BEEN SAVED FOR INVESTIGATION. THE FACILITY EMPLOYS THE MANUAL BREAK DETACHMENT METHOD. IT WAS REPORTED THAT THERE WAS NO DELAY TO THE PROCEDURE AS A RESULT OF THE REPORTED ISSUE. THE PROCEDURE WAS SUCCESSFULLY COMPLETED AND THERE WAS NO NEGATIVE PATIENT IMPACT. ON (B)(6), 2023, ADDITIONAL INFORMATION WAS RECEIVED. THE INFORMATION INDICATED THAT THE CONCOMITANT MICROCATHETER USED WAS THE SL-10® 45° MICROCATHETER (STRYKER). THE SAME MICROCATHETER WAS USED WITH THE FIRST COIL AND ALL SUBSEQUENT COMPETITOR COILS TO COMPLETE THE PROCEDURE. WHEN THE 14MM X 45CM HELIFORM COIL WAS REMOVED, NO STRETCHING WAS OBSERVED. THE PROCEDURE WAS COMPLETED WITH TWO MORE COMPETITOR COILS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18410639 ↗

Other Device, Vascular, for Promoting Embolization devices

All Device, Vascular, for Promoting Embolization devices →