CEREPAK HELIFORM SHD181445Recalls & reported problems
Cerenovus, Inc. · CEREPAK HELIFORM XL Detachable Coil Delivery System Length - 190 cm Coil Diameter - 14 mm Coil Length - 45 cm · Class 2 · Implant
All models of CEREPAK HELIFORM (48)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886704083559), received between Dec 28, 2023 and Dec 28, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Separation Failure” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Recalls naming this device
- Oct 2, 2025Class IOpen, Classified
Detachable coils system may fail to detach, which could result in hemorrhagic and ischemic stroke, procedural delays, or the need for additional surgical intervention.
Z-0434-2026 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Separation Failure1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 28, 2023Separation Failure; Separation Failure
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING THE COIL EMBOLIZATION PROCEDURE TARGETING A LEFT PERI-OPHTHALMIC ANEURYSM WITH THE CEREPAK COIL SYSTEM, THE FIRST COIL INTRODUCED WAS DETACHED WITHOUT ISSUE. THE SECOND COIL WAS A 14MM X 45CM CEREPAK HELIFORM XL (SHD181445 / 31154801) WAS INTRODUCED INTO THE ANEURYSM WITHOUT ISSUE. THE PHYSICIAN FOLLOWED TRAINING PROTOCOL BUT THE COIL WOULD NOT DETACH. THE COIL WAS REMOVED SAFELY; IT HAS BEEN SAVED FOR INVESTIGATION. THE FACILITY EMPLOYS THE MANUAL BREAK DETACHMENT METHOD. IT WAS REPORTED THAT THERE WAS NO DELAY TO THE PROCEDURE AS A RESULT OF THE REPORTED ISSUE. THE PROCEDURE WAS SUCCESSFULLY COMPLETED AND THERE WAS NO NEGATIVE PATIENT IMPACT. ON (B)(6), 2023, ADDITIONAL INFORMATION WAS RECEIVED. THE INFORMATION INDICATED THAT THE CONCOMITANT MICROCATHETER USED WAS THE SL-10® 45° MICROCATHETER (STRYKER). THE SAME MICROCATHETER WAS USED WITH THE FIRST COIL AND ALL SUBSEQUENT COMPETITOR COILS TO COMPLETE THE PROCEDURE. WHEN THE 14MM X 45CM HELIFORM COIL WAS REMOVED, NO STRETCHING WAS OBSERVED. THE PROCEDURE WAS COMPLETED WITH TWO MORE COMPETITOR COILS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18410639 ↗
FDA clearance and classification
Cleared through 510(k) K220040 on Jul 14, 2022 (decision: Substantially Equivalent). Submitted by Medos International SARL as “CEREPAK Uniform, Uniform XL, Uniform 3D, Heliform Soft, Heliform XtraSoft, Heliform XL, Heliform XtraSoft XL, Freeform, Freeform Mini, and Freeform XtraSoft Detachable Coil Systems”. The FDA review took 190 days. FDA record ↗
The FDA regulates product code KRD (device, vascular, for promoting embolization) under 21 CFR 870.3300 as a Class II device. 21 CFR 870.3300 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CEREPAK HELIFORM SHD181445
Has the CEREPAK HELIFORM SHD181445 been recalled?
Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-0434-2026 (Class I), began on Oct 2, 2025: Detachable coils system may fail to detach, which could result in hemorrhagic and ischemic stroke, procedural delays, or the need for additional surgical intervention. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
What problems have been reported with the CEREPAK HELIFORM SHD181445?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Dec 28, 2023. That report lists device problem “Separation Failure” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CEREPAK HELIFORM SHD181445?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CEREPAK HELIFORM SHD181445 FDA approved?
It was cleared through 510(k) K220040 on Jul 14, 2022. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the CEREPAK HELIFORM SHD181445 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the CEREPAK HELIFORM SHD181445, and is it still sold?
The FDA's device database lists Cerenovus, Inc. as the company responsible for it (brand CEREPAK HELIFORM, model SHD181445). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization117 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page