NA 214619Recalls & reported problems

Medos International Sàrl · Rasp - 20 Degrees Up Bend · Class 1

Adverse event reports
8
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 10886705004027), received between Dec 27, 2019 and Jul 8, 2026 — classified as 8 malfunctions.

The most frequently reported specific device problem is “Break” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break4
  • Material Deformation4
  • Material Twisted/Bent1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 8, 2026Break

    IT WAS REPORTED THAT DURING AN ARTHROSCOPIC ROTATOR CUFF REPAIR SURGERY, THE TIP OF A RASP DEVICE BROKE WHILE DETACHING TISSUE BETWEEN THE GLENOID CAVITY AND THE ROTATOR CUFF. ALL BROKEN FRAGMENTS OF THE RASP WERE REMOVED. THE SURGERY WAS COMPLETED WITHOUT DELAY OR PATIENT HARM. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25753094 ↗
  • MalfunctionApr 2, 2026Break

    IT WAS REPORTED THAT THE SHAFT PART OF THE ARTHRO RASP 20 UPBEND RASP DEVICE BROKE. THERE WAS NO ADVERSE CONSEQUENCE TO THE PATIENT. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24765290 ↗
  • MalfunctionDec 27, 2023Break; Material Deformation; Break; Material Deformation

    IT WAS REPORTED FROM JAPAN BY THE SALES REP THAT DURING AN UNSPECIFIED SURGICAL PROCEDURE ON (B)(6) 2023 THE CUTTING DEVICE WAS USED TO REMOVE AN ARTICULAR LIP FROM A GLENOID, AND THE RASP TIP WAS DEFORMED AND COULD NOT BE USED FOR SURGERY. ANOTHER RASP WAS USED IN THE SAME WAY, AND IT WAS ALSO DEFORMED. WHEN THE SURGEON ATTEMPTED TO PUT IT BACK ON THE OPERATING TABLE, THE RASP IN QUESTION BROKE OFF. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO DELAY IN THE PROCEDURE REPORTED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18401923 ↗
  • MalfunctionApr 5, 2023Material Deformation; Material Deformation

    THIS IS REPORT 1 OF 4 FOR (B)(4). IT WAS REPORTED BY A HEALTHCARE PROFESSIONAL IN AUSTRALIA THAT DURING AN ARTHROSCOPIC SHOULDER STABILIZATION PROCEDURE ON (B)(6) 2023, IT WAS OBSERVED THAT THE RASP - 20 DEGREES UP BEND DEVICE WAS BENT. IT WAS UNKNOWN IF AND HOW THE PROCEDURE WAS COMPLETED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16685686 ↗
  • MalfunctionNov 9, 2022Material Deformation; Material Deformation

    IT WAS REPORTED BY A HEALTHCARE PROFESSIONAL IN AUSTRALIA THAT DURING AN UNKNOWN SURGERY ON (B)(6) 2022, IT WAS OBSERVED THAT THE UP LIBERATOR RASP 20° UP BEND WAS CLEARLY BENT WHEN THE LOAN TRAY WAS OPENED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15763967 ↗
  • MalfunctionMay 4, 2022Material Deformation; Material Deformation

    THIS IS REPORT 2 OF 2 IN (B)(4). IT WAS REPORTED BY THE SALES REP THAT DURING AN UNKNOWN PROCEDURE ON (B)(6) 2022, IT WAS OBSERVED THAT THE RASP 20° UP BEND WAS BENT. THE SAME DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WERE NO ADVERSE PATIENT CONSEQUENCES NOR SURGICAL DELAY REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14278942 ↗
  • MalfunctionApr 20, 2021Break; Break

    IT WAS REPORTED BY THE AFFILIATE IN (B)(6) THAT THE TIP ON THE BONE RASP DEVICE WAS BROKEN. THERE WAS NO PROCEDURE NOR PATIENT INVOLVEMENT REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11695348 ↗
  • MalfunctionDec 27, 2019Material Twisted/Bent; Material Twisted/Bent

    IT WAS REPORTED BY AFFILIATE VIA EMAIL THAT DURING AN UNKNOWN PROCEDURE THE SURGEON NOTICED THAT RASP SHAFT OF A RASP 20° UP BEND, WAS BENT. THE SURGERY WAS COMPLETED BY USING THE SAME BENT INSTRUMENT. NO SURGICAL DELAY OR PATIENT CONSEQUENCE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9526886 ↗

Other ACCESSORIES,ARTHROSCOPIC devices

All ACCESSORIES,ARTHROSCOPIC devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.