NA 03.008.011Recalls & reported problems
Synthes GmbH · SPIRAL BLADE INSERTER FOR HINDFOOT ARTHRODESIS NAIL-EX · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 10886982066909), received between Jan 24, 2017 and Aug 24, 2023 — classified as 8 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break4
- Contamination /Decontamination Problem3
- Device-Device Incompatibility1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- No Patient Involvement3
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 24, 2023Contamination /Decontamination Problem; Contamination /Decontamination Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, THE INSTRUMENTS WERE DELIVERED WITH BLOOD RESIDUES. THIS REPORT INVOLVES ONE (1) SPIRAL BLADE INSERTER FOR HINDFOOT ARTHRODESIS NAIL-EX. THIS IS REPORT 3 OF 3 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17612132 ↗MalfunctionAug 24, 2023Contamination /Decontamination Problem; Contamination /Decontamination Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN LUXEMBOURG AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6), 2023, THE INSTRUMENTS WERE DELIVERED WITH BLOOD RESIDUES. THIS REPORT INVOLVES ONE (1) SPIRAL BLADE INSERTER FOR HINDFOOT ARTHRODESIS NAIL-EX. THIS IS REPORT 2 OF 3 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17612108 ↗MalfunctionAug 24, 2023Contamination /Decontamination Problem; Contamination /Decontamination Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, THE INSTRUMENTS WERE DELIVERED WITH BLOOD RESIDUES. THIS REPORT INVOLVES ONE (1) SPIRAL BLADE INSERTER FOR HINDFOOT ARTHRODESIS NAIL-EX. THIS IS REPORT 1 OF 3 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17612068 ↗MalfunctionApr 25, 2022Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM DEPUY SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: THIS IS REPORT 2 OF 3 FOR (B)(4). IT WAS REPORTED BY THE CUSTOMER IN (B)(6) THAT DURING A HIND FOOT NAIL ORTHOPEDIC SURGERY ON (B)(6) 2022, IT WAS OBSERVED THAT THE SPIRAL BLADE DEVICE COULD NOT GET THE BLADE INSERTER THROUGH THE AIMING ARM ADAPTER DEVICE. IT WAS REPORTED THAT THE SURGEON ATTEMPTED THIS A COUPLE OF TIMES BUT HAD TO GO TO THE SPIRAL BLADE EXTRACTION TOOL TO INSERT THE BLADE. ACCORDING TO THE REPORT, THE SURGEON ATTEMPTED TO GET THE INSERTER THROUGH THE AIMING ADAPTER BUT STILL WOULD NOT GO THROUGH. IT WAS REPORTED THAT THE REPORTER CLAIMED THAT IT LOOKED LIKE THAT THE INSERTER HAD A BIGGER DIAMETER THAN THE HOLE OF THE ADAPTER. ANOTHER LIKE DEVICE WAS USED TO COMPLETE THE PROCEDURE WITH A DELAY OF 10 MINUTES. THERE WERE NO ADVERSE PATIENT CONSEQUENCES REPORTED. NO ADDITIONAL INFORMATION WAS PROVIDED. THIS REPORT IS FOR ONE (1) SPIRAL BLADE INSERTER F/EXPERT HAN DEVICE. THIS COMPLAINT INVOLVES 3 DEVICES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14192933 ↗MalfunctionMar 3, 2021Break; Break
IT WAS REPORTED THAT ON AN UNKNOWN DATE, DURING A ROUTINE INCOMING INSPECTION OF A LOANER SET, IT WAS OBSERVED THAT SPIRAL BLADE INSERTER WAS BROKEN. THERE WAS NO KNOWN PATIENT OR HOSPITAL INVOLVEMENT. THIS REPORT IS FOR ONE (1) SPIRAL BLADE INSERTER FOR HINDFOOT ARTHRODESIS NAIL-EX. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11405698 ↗MalfunctionMar 25, 2020Break; Break
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THE DEVICE BROKE DURING A PROCEDURE ON AN UNKNOWN DATE DUE TO FATIGUE OF MATERIAL. THE PROCEDURE WAS SUCCESSFULLY FINISHED WITH A 20 MINUTE SURGICAL DELAY. THERE WERE NO PATIENT CONSEQUENCES. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Patient Involvement
MAUDE report 9878390 ↗MalfunctionSep 12, 2019Break; Break
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE SPIRAL BLADE INSERTER WAS BROKEN. THE METAL RETAINING CLIP IN THE PROXIMAL END OF THE SPIRAL BLADE INSERTER BROKE. IT NO LONGER KEEPS THE SLEEVE ON AND DOES NOT SELF-RETAIN TO THE SHAFT. THE ISSUE WAS DISCOVERED AFTER OPENING THE TRAY. THERE WAS NO PATIENT INVOLVEMENT. THIS REPORT IS FOR ONE (1) SPIRAL BLADE INSERTER FOR HINDFOOT ARTHRODESIS NAIL. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Patient Involvement
MAUDE report 9010115 ↗MalfunctionJan 24, 2017Break; Break
IT WAS REPORTED THAT THE SPIRAL BLADE INSERTER WAS FOUND BROKEN AT THE LOAN SET. THE T-SHAPE END OF THE INSERTER IS LOOSE. THE INSTRUMENT DID NOT BROKE AT THE LOAN DEPARTMENT. NO PATIENT INVOLVEMENT.. THE PART HAS A BROKEN PIN AND HAS A VERY USED CONDITION. THIS COMPLAINT INVOLVES 1 PART. THIS REPORT IS 1 OF 1 FOR (B)(4).
Patient problems: No Patient Involvement
MAUDE report 6273723 ↗
Other Guide, surgical, instrument devices
- NA 03.037.017Synthes GmbH · Guide, surgical, instrument346 reports
- EVOS 71174934Smith & Nephew, Inc. · Guide, surgical, instrument149 reports
- LCP 323.042Synthes GmbH · Guide, surgical, instrument129 reports
- DJO SURGICAL 342-10-705Encore Medical, L.P. · Guide, Surgical, Instrument1 recall51 reports
- DJO SURGICAL 341-10-707Encore Medical, L.P. · Guide, Surgical, Instrument81 reports
- NA 03.010.404Synthes GmbH · Guide, surgical, instrument73 reports
- DJO SURGICAL 341-14-708Encore Medical, L.P. · Guide, Surgical, Instrument1 recall22 reports
- DJO SURGICAL 341-10-711Encore Medical, L.P. · Guide, Surgical, Instrument1 recall16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page