NA 03.010.081Recalls & reported problems

Synthes GmbH · 15.0MM/13.0MM PROTECTION SLEEVE F/SPIRAL BLD AIMING ARM · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10886982067517), received between Apr 25, 2022 and Jan 6, 2025 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Device-Device Incompatibility” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 2 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility5
  • Material Deformation1
  • Material Integrity Problem1
  • Material Twisted/Bent1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • Burn(s)1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 6, 2025Device-Device Incompatibility; Material Integrity Problem; Device-Device Incompatibility; Material Integrity Problem

    THE SLEEVE HAD A SMALL DAMAGE AT THE TIP, AND COULD NOT BE INSERTED INTO THE AIMING ARM ATTACHMENT/COULD ONLY BE INSERTED WITH FORCE. NO PATIENT IMPACT OR SURGICAL DELAY HAS BEEN REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21079435 ↗
  • MalfunctionDec 28, 2023Material Deformation; Material Deformation

    DEVICE REPORT FROM CANADA REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON 05-DECEMBER-2023, THE POSITIVE-DRILL STOP FEATURE ON THE SHAFT IN QUESTION WAS FOUND TO BE WORN. BECAUSE OF THIS WEAR, THE SLEEVE NO LONGER STOPS DRILL BITS FROM ENTERING IN TOO FAR. THERE WAS NO ADVERSE PATIENT IMPACT. NO FURTHER INFORMATION IS AVAILABLE TO REPORT. THIS REPORT IS FOR A 15.0MM/13.0MM PROTECTION SLEEVE F/SPIRAL BLD AIMING ARM. THIS IS REPORT 1 OF 1 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18412147 ↗
  • MalfunctionNov 24, 2023Device-Device Incompatibility; Material Twisted/Bent; Device-Device Incompatibility; Material Twisted/Bent

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN CANADA AS FOLLOWS: IT WAS REPORTED ON (B)(6) 2023, THAT THE SURGEON REPORTED THAT THE DRILL BIT WAS BINDING INSIDE THE PROTECTION SLEEVE WHILE PREPARING FOR A SPIRAL BLADE WHILE USING THE RETROGRADE/ANTEGRADE FEMORAL NAIL INSTRUMENTS. THE POSITIVE STOP FEATURE BETWEEN THE SLEEVE AND DRILL BIT WAS WORN, CAUSING THE DRILL BIT TO PASS TOO DEEP INTO THE SLEEVE AND CAUSING THE BIT TO BIND WITHIN THE SLEEVE. AS A RESULT OF THE BINDING, THE DRILL BIT AND SLEEVE BECAME HOT, RESULTING IN A MINOR THERMAL INJURY TO THE PATIENT¿S SKIN. THE INSTRUMENTS WERE REMOVED FROM THE SET AND DISCARDED. THE INSTRUMENTS REQUIRE REPLACEMENT. THERE WERE PATIENT OUTCOMES AND CONSEQUENCES. THERE WAS A THERMAL INJURY TO THE PATIENT'S SKIN. THIS REPORT IS FOR ONE (1) PROTECT SLEEVE 15/13 F/SPIR BLADE LOCK Y. THIS IS REPORT 2 OF 2 FOR COMPLAINT (B)(4).

    Patient problems: Burn(s)

    MAUDE report 18204388 ↗
  • MalfunctionNov 21, 2023Device-Device Incompatibility; Device-Device Incompatibility

    DEVICE REPORT FROM CANADA REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT UPON INSPECTION FOLLOWING A PROCEDURE ON (B)(6) 2023, STAFF NOTED THAT A DRILL BIT WAS BINDING INSIDE A PROTECTION SLEEVE. PROCEDURE HAD BEEN COMPLETED WITH NO DELAY. THERE WAS NO PATIENT CONSEQUENCE. THIS REPORT IS FOR A 15.0MM/13.0MM PROTECTION SLEEVE F/SPIRAL BLD AIMING ARM. THIS IS REPORT 2 OF 2 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18187161 ↗
  • MalfunctionSep 2, 2022Device-Device Incompatibility; Device-Device Incompatibility

    DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT DURING A PROCEDURE ON (B)(6) 2022, THE 13.0MM CANNULATED DRILL BIT ¿SHOULDERS¿ COULD PASS THE AUTOMATIC STOP POSITION AND ENTER INTO THE 15.0MM/13.0MM PROTECTION SLEEVE. THE REAMER WOULD GO THROUGH THE SLEEVE ANOTHER 10MM OR SO. PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A THIRTY SECOND DELAY. THERE WAS NO PATIENT CONSEQUENCE. THIS REPORT IS FOR A 15.0MM/13.0MM PROTECTION SLEEVE F/SPIRAL BLD AIMING ARM. THIS IS REPORT 2 OF 2 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15348311 ↗
  • MalfunctionApr 25, 2022Device-Device Incompatibility; Device-Device Incompatibility

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN THE (B)(6) AS FOLLOWS: IT WAS REPORTED THAT A 15/13 F/SPIRAL BLADE-LOCK PROTECT SLEEVE AND A 13.0MM/3.2MM WIRE GUIDE FOR SPIRAL BLADE AIMING ARM WERE DAMAGED UPON INSPECTION OF INSTRUMENTS PRIOR TO SURGERY. THE SLEEVE WAS STATED TO NOT FIT THROUGH THE JIG EASILY. THERE WERE NO PATIENT CONSEQUENCES. THIS REPORT IS FOR ONE (1) DRILLSL 13/3.2 F/03.010.081 YELL. THIS IS REPORT 2 OF 2 FOR COMPLAINT (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14192968 ↗

Other Guide, surgical, instrument devices