NA 03.226.000Recalls & reported problems
Synthes GmbH · COMPRESSION SLEEVE FOR 3.0MM HEADLESS COMPRESSION SCREW · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982077004), received between Mar 31, 2020 and Mar 31, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Manufacturing, Packaging or Shipping Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Manufacturing, Packaging or Shipping Problem1
Patient problems
- Injury1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 31, 2020Manufacturing, Packaging or Shipping Problem; Manufacturing, Packaging or Shipping Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(6) AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2020, THE PATIENT UNDERWENT A SURGERY WITH HEADLESS COMPRESSION SCREWS. DURING THE SURGERY, THE SURGEON FOUND THAT THE INSTRUMENT SET DELIVERED TO THE HOSPITAL CONTAINED THE COMPRESSION SLEEVE FOR 3.0 MM (03.226.000) INSTEAD OF THE COMPRESSION SLEEVE FOR 2.4 MM (03.226.016). THE SURGEON HAD NO CHOICE BUT TO INSERT 3.0 MM HEADLESS COMPRESSION SCREWS. HE HAS CONCERN FOR SECONDARY FRACTURE BECAUSE THE CORTICAL BONE BECAME THINNER DUE TO THE INSERTED SCREW SIZE WHICH IS LONGER THAN PLANNED ONE. THERE WAS NO REPORTED DELAY. THE PATIENT OUTCOME WAS STABLE. THIS COMPLAINT INVOLVES TWO (2) DEVICES. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: Injury
MAUDE report 9907781 ↗
Other Guide, surgical, instrument devices
- NA 03.037.017Synthes GmbH · Guide, surgical, instrument346 reports
- EVOS 71174934Smith & Nephew, Inc. · Guide, surgical, instrument149 reports
- LCP 323.042Synthes GmbH · Guide, surgical, instrument129 reports
- DJO SURGICAL 342-10-705Encore Medical, L.P. · Guide, Surgical, Instrument1 recall51 reports
- DJO SURGICAL 341-10-707Encore Medical, L.P. · Guide, Surgical, Instrument81 reports
- NA 03.010.404Synthes GmbH · Guide, surgical, instrument73 reports
- DJO SURGICAL 341-14-708Encore Medical, L.P. · Guide, Surgical, Instrument1 recall22 reports
- DJO SURGICAL 341-10-711Encore Medical, L.P. · Guide, Surgical, Instrument1 recall16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page