MULTILOC 04.019.285SRecalls & reported problems
Synthes GmbH · 8.5MM TI MULTILOC HUMERAL NAIL LEFT/CANN/285MM-STERILE · Class 2 · Implant
All models of MULTILOC (48)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982090119), received between Feb 13, 2023 and Feb 13, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
- Material Integrity Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 13, 2023Device-Device Incompatibility; Material Integrity Problem; Device-Device Incompatibility; Material Integrity Problem
DEVICE REPORT FROM THE UNITED KINGDOM REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, THE PATIENT UNDERWENT A HUMERAL NAIL OPERATION USING THE MULTILOC FOR MULTI MYELOMA CONDITION. THE PATIENT HAD RECENTLY UNDERGONE THE SAME OPERATION BUT ON THE OTHER HUMERUS. ENTRY POINT WAS FOUND AND OPENED IN THE CORRECT SURGICAL TECHNIQUE. AS THE SURGEON HAD USED Ø8.5 ON THE OTHER SIDE HE OPTED TO USE THE SAME DIAMETER FOR THE LEFT. NAIL INSERTED EASILY THROUGH THE PROXIMAL END OF THE HUMERUS AND MID SHAFT FRACTURE BUT INSERTION INTO THE DISTAL END WAS AIDED BY USE OF HAMMER. THE IM CANAL WAS NOT REAMED BEFORE THE NAIL INSERTION. WHEN THE SURGEON WAS TRYING TO ALIGN AND ROTATE THE NAIL SO DISTAL HOLES WERE ALIGNED CORRECTLY AND THE PROXIMAL END WAS ALSO ALIGNED, HE WAS HAVING TO USE CONSIDERABLE FORCE. AFTER SOME TIME OF TRYING TO ROTATE IT WAS NOTICED THAT THE CONNECTING SCREW WAS ROTATING WHEN ROTATING THE ARM TO CHECK BOTH VIEWS. THE SURGEON REMOVED THE NAIL, WHICH WAS WHEN IT WAS NOTICED THAT THE VERY PROXIMAL END OF THE NAIL WAS DAMAGED AT THE INSERTION ARM / NAIL CONNECTION JOINT. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR AN 8.5MM TI MULTILOC HUMERAL NAIL L
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16363841 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE Intramedullary Limb Lengthening System LSB5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.