LCP 223.406Recalls & reported problems
Synthes GmbH · 3.5MM LCP® METAPHYSEAL PLATE 6 HOLES · Class 2 · Implant
All models of LCP (367)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982157584), received between May 24, 2018 and May 14, 2024 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Impaired Healing1
- Unspecified Infection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMay 14, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IN COLLABORATION WITH DEPUY SYNTHES TOGETHER WITH (B)(6) HOSPITAL A RETROSPECTIVE DATA COLLECTION WAS PERFORMED ON PATIENTS WHO RECEIVED LOCKING COMPRESSION PLATES. DATES ARE NOT INCLUDED IN THE DATA DUE TO PRIVACY RESTRICTIONS. PATIENT #10: 51-YEAR-OLD MALE WAS IMPLANTED WITH LCP METAPHYSEAL PLATES 3.5 (223.406) IN ANKLE WITH DPS SCREWS (UNKNOWN QUANTITY) WITH NO ADJUNCTIVE FIXATION DEVICE. POST-OPERATIVE COMPLICATION: INFECTION EXPERIENCED 12 WEEKS POST-OP RELATED TO BOTH SYNTHES DEVICE AND PROCEDURE. TREATMENT: SURGICAL TREATMENT FOR I&D AND HARDWARE REMOVAL OF PLATE AND SCREWS PERFORMED 12 WEEKS POST-OP. OUTCOME: RECOVERED/RESOLVED. THIS REPORT IS FOR ONE 3.5MM LCP METAPHYSEAL PLATE 6 HOLES FOR (B)(4).
Patient problems: Unspecified Infection
MAUDE report 19315957 ↗InjuryMay 24, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A HARDWARE REMOVAL OF THE LOCKING COMPRESSION PLATE (LCP) METAPHYSEAL PLATE AND FOUR (4) CORTEX SCREWS ON (B)(6) 2018 DUE TO NON-UNION. THE PATIENT WAS REVISED TO A NEW PLATE. THE SURGEON ALSO USED BONE VOID (VIVIGEN 5CC). THE PROCEDURE WAS COMPLETED SUCCESSFULLY, WITH NO REPORTED DELAY. PATIENT OUTCOME WAS STABLE. THIS REPORT IS FOR A 3.5MM LCP® METAPHYSEAL PLATE 6 HOLES. THIS IS REPORT 2 OF 2 FOR (B)(4).
Patient problems: Impaired Healing
MAUDE report 7539976 ↗
Other APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE devices
- LOCK SCREW SQUARE DRIVE 131827118Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE1 recall0 reports
- LOCK SCREW SQUARE DRIVE 131827120Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE1 recall0 reports
- IJS IJS-E Base Plate AssemblySkeletal Dynamics L.L.C. · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE28 reports
- NA 390.008Synthes GmbH · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE21 reports
- NA 294.56Synthes GmbH · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE8 reports
- NA 390.003Synthes GmbH · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE8 reports
- NA 394.85Synthes GmbH · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE8 reports
- TRUE/LOK MONOLATERAL/BILATERAL FIXATOR 1Orthofix Srl · Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page