TRUE/LOK MONOLATERAL/BILATERAL FIXATOR 1 (REF 54-1139)Recalls & reported problems

Orthofix Srl · TL PLUS WIRE TENSIONER WITH TIP · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 18033509856563), received between Jul 2, 2024 and Dec 4, 2025 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Mechanical Problem” (6 reports).

1 other recall cover devices cleared under the same FDA submission (K941048); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 2 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 2 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Mechanical Problem6

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 4, 2025Mechanical Problem; Mechanical Problem

    RECEIVED INFORMATION STATING THAT USER EXPERIENCED TENSION ISSUES ON TWO TENSIONERS DURING SURGERY OF A FRACTURED TIBIA. AS PER REPORTER SURGICAL PROCEDURE WAS DELAYED BY APPROXIMATELY 60 MINUTES. THE PATIENT IS REPORTED AS BEING IN RECOVERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23714659 ↗
  • MalfunctionDec 4, 2025Mechanical Problem; Mechanical Problem

    RECEIVED INFORMATION STATING THAT USER EXPERIENCED TENSION ISSUES ON TWO TENSIONERS DURING SURGERY OF A FRACTURED TIBIA. AS PER REPORTER SURGICAL PROCEDURE WAS DELAYED BY APPROXIMATELY 60 MINUTES. THE PATIENT IS REPORTED AS BEING IN RECOVERY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23714593 ↗
  • MalfunctionOct 11, 2024Mechanical Problem; Mechanical Problem

    THE INFORMATION PROVIDED BY LOCAL DISTRIBUTOR INDICATES: - HOSPITAL NAME: (B)(6). - SURGEON'S NAME: (B)(6). - DATE OF INITIAL SURGERY: (B)(6) 2024. - BODY PART TO WHICH DEVICE WAS APPLIED: TIBIA. - SURGERY DESCRIPTION: PILON FX -EX FIX APPLICATION. - SURGERY DESCRIPTION: FRACTURE TREATMENT. - PATIENT INFORMATION: 49-YEAR-OLD, FEMALE. - PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE. - TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM. - EVENT DESCRIPTION: NEITHER WIRE TENSIONERS IN INSTRUMENT SET TENSIONED WIRES. THEY WERE NEW TENSIONERS, BUT THEY WERE. IMPOSSIBLE TO SQUEEZE. WIRES WILL NEED TO BE REPLACED AND PROPERLY TENSIONED IN AN ADDITIONAL SURGERY. THE COMPLAINT REPORT FORM ALSO INDICATES: - THE DEVICE FAILURE HAD ADVERSE EFFECTS ON PATIENT: LOSS OF FRACTURE REDUCTION. - THE INITIAL SURGERY WAS NOT COMPLETED WITH THE DEVICE. - A REPLACEMENT DEVICE WAS NOT AVAILABLE TO COMPLETE SURGERY: WIRES WERE LEFT LOOSE. - THE EVENT LED TO A DELAY IN THE DURATION OF THE SURGICAL PROCEDURE: 40 MINUTES. - AN ADDITIONAL SURGERY IS REQUIRED: TO BE DEFINED. - A MEDICAL INTERVENTION (OUTPATIENT CLINIC) WAS NOT REQUIRED. - COPIES OF THE OPERATIVE REPORTS ARE NOT AVAILABLE. - COPIES OF

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20429861 ↗
  • MalfunctionOct 11, 2024Mechanical Problem; Mechanical Problem

    THE INFORMATION PROVIDED BY LOCAL DISTRIBUTOR INDICATES: HOSPITAL NAME: (B)(6), SURGEON'S NAME: DR.(B)(6), DATE OF INITIAL SURGERY: ON (B)(6)2024, BODY PART TO WHICH DEVICE WAS APPLIED: TIBIA, SURGERY DESCRIPTION: PILON FX -EX FIX APPLICATION, SURGERY DESCRIPTION: FRACTURE TREATMENT, PATIENT INFORMATION: 49-YEAR-OLD, FEMALE, PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE, TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM. EVENT DESCRIPTION: NEITHER WIRE TENSIONERS IN INSTRUMENT SET TENSIONED WIRES. THEY WERE NEW TENSIONERS, BUT THEY WERE IMPOSSIBLE TO SQUEEZE. WIRES WILL NEED TO BE REPLACED AND PROPERLY TENSIONED IN AN ADDITIONAL SURGERY. THE COMPLAINT REPORT FORM ALSO INDICATES: THE DEVICE FAILURE HAD ADVERSE EFFECTS ON PATIENT: LOSS OF FRACTURE REDUCTION THE INITIAL SURGERY WAS NOT COMPLETED WITH THE DEVICE A REPLACEMENT DEVICE WAS NOT AVAILABLE TO COMPLETE SURGERY: WIRES WERE LEFT LOOSE THE EVENT LED TO A DELAY IN THE DURATION OF THE SURGICAL PROCEDURE: 40 MINUTES AN ADDITIONAL SURGERY IS REQUIRED: TO BE DEFINED A MEDICAL INTERVENTION (OUTPATIENT CLINIC) WAS NOT REQUIRED COPIES OF THE OPERATIVE REPORTS ARE NOT AVAILABLE COPIES OF THE X-RAY IMAGES ARE AVAILABLE (NOT REC

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20427086 ↗
  • MalfunctionJul 2, 2024Mechanical Problem; Mechanical Problem

    THE INFORMATION PROVIDED STATES: HOSPITAL NAME: (B)(6) HOSPITAL SURGEON'S NAME: DR.(B)(6). DATE OF INITIAL SURGERY: UNKNOWN. BODY PART TO WHICH DEVICE WAS APPLIED: UNKNOWN. SURGERY DESCRIPTION: CORRECTION. PATIENT INFORMATION: N/A. PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE. TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM. EVENT DESCRIPTION: THE TENSIONERS PART NUMBER 54- 1139 X 2 WOULD NOT TENSION DURING THE SURGERY. THE TERRITORY MANAGER STATES THAT THERE WAS ABOUT AN HOUR DELAY IN THE SURGERY BUT NO AFFECT ON THE PATIENT. THEY WERE ABLE TO COMPLETE THE SURGERY WITHOUT FURTHER ISSUES. THE COMPLAINT REPORT FORM ALSO INDICATES: THE DEVICE FAILURE HAD NO ADVERSE EFFECTS ON PATIENT. THE INITIAL SURGERY WAS COMPLETED WITH THE DEVICE. THE EVENT LED TO A DELAY IN THE DURATION OF THE SURGICAL PROCEDURE: ABOUT AN HOUR. AN ADDITIONAL SURGERY IS NOT REQUIRED. A MEDICAL INTERVENTION (OUTPATIENT CLINIC) WAS NOT REQUIRED. COPIES OF THE OPERATIVE REPORTS ARE NOT AVAILABLE. COPIES OF THE X-RAY IMAGES ARE NOT AVAILABLE. PATIENT CURRENT HEALTH CONDITION: UNKNOWN. PLEASE ALSO REFER TO MFR REPORT 2183449-2024-00008.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19657822 ↗
  • MalfunctionJul 2, 2024Mechanical Problem; Mechanical Problem

    THE INFORMATION PROVIDED STATES: - HOSPITAL NAME: (B)(6) - SURGEON'S NAME: (B)(6) - DATE OF INITIAL SURGERY: UNKNOWN - BODY PART TO WHICH DEVICE WAS APPLIED: UNKNOWN - SURGERY DESCRIPTION: CORRECTION - PATIENT INFORMATION: N/A - PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE - TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM - EVENT DESCRIPTION: THE TENSIONERS PART NUMBER 54- 1139 X 2 WOULD NOT TENSION DURING THE SURGERY. THE TERRITORY MANAGER STATES THAT THERE WAS ABOUT AN HOUR DELAY IN THE SURGERY BUT NO AFFECT ON THE PATIENT. THEY WERE ABLE TO COMPLETE THE SURGERY WITHOUTH FUTHER ISSUES. THE COMPLAINT REPORT FORM ALSO INDICATES: - THE DEVICE FAILURE HAD NO ADVERSE EFFECTS ON PATIENT - THE INITIAL SURGERY WAS COMPLETED WITH THE DEVICE - THE EVENT LED TO A DELAY IN THE DURATION OF THE SURGICAL PROCEDURE: ABOUT AN HOUR - AN ADDITIONAL SURGERY IS NOT REQUIRED - A MEDICAL INTERVENTION (OUTPATIENT CLINIC) WAS NOT REQUIRED - COPIES OF THE OPERATIVE REPORTS ARE NOT AVAILABLE - COPIES OF THE X-RAY IMAGES ARE NOT AVAILABLE - PATIENT CURRENT HEALTH CONDITION: UNKNOWN PLEASE ALSO REFER TO MFR REPORT 2183449-2024-00009.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19655903 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K941048. One submission often covers many models, so check the product and lot details in each record.

  • Z-0674-2008 · Sep 28, 2007 · Terminated
    Orthofix TrueLok External Ring Fixation System, Telescopic Linear Distractor, Threaded in the following sizes: 75mm (Catalog Number: 50-1101), 100mm (Catalog Number: 50-1014), 150m

Other Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite devices

All Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page