NA 242.510Recalls & reported problems
Synthes (U.S.A.) LP · WRIST FUSION PLATE 8 HOLES/STANDARD · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982168696), received between Dec 5, 2017 and Dec 5, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
- Material Fragmentation1
Patient problems
- Failure of Implant1
- Nonunion/Delayed-union Bone Fracture1
- Unspecified Infection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 5, 2017Break; Material Fragmentation; Break; Material Fragmentation
IT WAS REPORTED THAT A PATIENT UNDERWENT A HARDWARE REMOVAL AND REVISION ON (B)(6) 2017 DUE TO BROKEN WRIST FUSION PLATE, NONUNION AND INFECTION. HARDWARE WAS ORIGINALLY IMPLANTED ON AN UNKNOWN DATE OF (B)(6) 2014. THE PATIENT IS REPORTED TO HAVE PRESENTED TO THE SURGEON WITH A BROKEN PLATE, THUS LEADING TO THE HARDWARE REMOVAL BEING SCHEDULED. THE SURGEON REMOVED ONE (1) WRIST FUSION PLATE, ONE (1) DISTAL RADIAL PLATE, SEVEN (7) 2.7 MM CORTEX SCREWS AND THREE (3) 3.5 MM CORTEX SCREWS, AND REPLACED THE HARDWARE WITH A K-WIRE FIXATION INCLUDING AN UNKNOWN QUANTITY OF K-WIRES AND AN ANTIBIOTIC CEMENT FOR INFECTION. IT WAS ALSO REPORTED THAT FRAGMENTS WERE GENERATED FROM THE BROKEN WRIST FUSION PLATE AND WERE RETAINED IN THE PATIENT. PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT ANY SURGICAL DELAY. PATIENT¿S OUTCOME REPORTED AS OKAY. THIS REPORT IS FOR ONE (1) WRIST FUSION PLATE 8 HOLES/STANDARD. (B)(4).
Patient problems: Failure of Implant; Nonunion/Delayed-union Bone Fracture; Unspecified Infection
MAUDE report 7083522 ↗
Other APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE devices
- LOCK SCREW SQUARE DRIVE 131827118Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE1 recall0 reports
- LOCK SCREW SQUARE DRIVE 131827120Biomet Orthopedics, LLC · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE1 recall0 reports
- IJS IJS-E Base Plate AssemblySkeletal Dynamics L.L.C. · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE28 reports
- NA 390.008Synthes GmbH · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE21 reports
- NA 294.56Synthes GmbH · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE8 reports
- NA 390.003Synthes GmbH · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE8 reports
- NA 394.85Synthes GmbH · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE8 reports
- NA 390.051Synthes GmbH · APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT, METAL COMPOSITE6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page