NA 259.36Recalls & reported problems
Synthes (U.S.A.) LP · 4.9MM LOCKING BOLT 36MM · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982172587), received between Aug 16, 2018 and Aug 16, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Failure of Implant1
- Inflammation1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 16, 2018Break; Break
IT WAS REPORTED THAT A PATIENT SUFFERED A MOTORCYCLE ACCIDENT ON (B)(6) 2008, RESULTING IN AN OPEN FRACTURE IN THE TIBIA AND FIBULA OF THE RIGHT LOWER LEG. ON (B)(6) 2008, THE PATIENT UNDERWENT SURGERY BY PLACING 5 SCREWS AND ONE UNKNOWN SYNTHES PLATE ON THE RIGHT FIBULA AND A UNIVERSAL TIBIAL NAIL AND 4 LOCKING BOLTS ON THE RIGHT TIBIA. ON AN UNKNOWN DATE, IT WAS REPORTED THAT THE PATIENT HAD ALMOST UNBEARABLE PAIN DAILY AND HIS PHYSICAL CONDITION DID NOT IMPROVE. HIS ANKLE REMAINED INFLAMED WITHOUT SIGNS OF IMPROVEMENT. IT WAS DISCOVERED THAT A LOCKING BOLT, USED WITH THE UNIVERSAL TIBIAL NAIL, HAD BROKEN. ON (B)(6) 2008 THE PATIENT UNDERWENT A REVISION TO REMOVE THE BROKEN LOCKING BOLT AND A NEW LOCKING BOLT WAS IMPLANTED. APPROXIMATELY 6 MONTHS LATER ((B)(6) 2009) THE PATIENT FELT UNBEARABLE PAIN AND ON (B)(6) 2009, CT SCAN CONCLUSION WAS THAT THE UNIVERSAL TIBIAL NAIL HAD BROKEN. CT CONCLUSION RESULTS STATED THAT THE PATIENT HAD CONTROL OF OSTEOSYNTHESIS OF TIBIAL AND FIBULAR FRACTURES, WITH DISTAL TIBIAL-FIBULAR TRACES, AND IN THE MIDDLE THIRD OF THE TIBIAL SHAFT. NON-REACTIVE CONSOLIDATION DELAY OF TIBIAL FRACTURES, WITH SATISFACTORY CONSOLIDATION OF THE FIBULA. ASSOCIATED F
Patient problems: Failure of Implant; Inflammation; Pain
MAUDE report 7790008 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE Intramedullary Limb Lengthening System LSB5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page