Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10886982176332), received between Mar 21, 2018 and Nov 15, 2022 — classified as 3 injuries.

The most frequently reported specific device problem is “Device Operates Differently Than Expected” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Device Operates Differently Than Expected1

Patient problems

  • No Code Available2
  • Necrosis1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 15, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED PATIENT UNDERWENT DYNAMIC HIP SYSTEM (DHS). THERE WAS AVN/OSTEONECROSIS OF THE FEMORAL HEAD. POSTOPERATIVE COMPLICATIONS REPORTED. THIS REPORT IS FOR ONE (1) 135 DEG DHS PL-STD BARREL 2 HOLES/46. THIS IS REPORT 2 OF 4 FOR COMPLAINT (B)(4).

    Patient problems: Necrosis

    MAUDE report 15800830 ↗
  • InjuryOct 5, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON (B)(6) 2020, THE PATIENT UNDERWENT HARDWARE REMOVAL DUE TO PROXIMAL FEMUR FRACTURE LOSS OF REDUCTION WITH DYNAMIC HIP SCREW SYSTEM (DHS) + CANNULATED SCREW AND WAS REVISED TO TOTAL HIP. THE PROCEDURE OUTCOME AND PATIENT'S STATUS ARE UNKNOWN. THIS COMPLAINT INVOLVES THREE (3) DEVICES. THIS REPORT IS FOR (1) DHS®/DCS® LAG SCREW 12.7MM THREAD/95MM. THIS IS REPORT 2 OF 4 FOR (B)(4).

    Patient problems: No Code Available

    MAUDE report 10629380 ↗
  • InjuryMar 21, 2018Device Operates Differently Than Expected; Device Operates Differently Than Expected

    IT WAS REPORTED THAT DURING A UNKNOWN PROCEDURE ON (B)(6) 2018, WHILE THE SURGEON WAS USING THE DHS®/DCS® WRENCH, FOR INSERTING A DHS®/DCS® COUPLING SCREW, UPON INSERTION INTO THE FEMORAL HEAD, THE DHS®/DCS® WRENCH WOULD NOT DISCONNECT AND SLIDE OFF FROM GUIDE SHAFT ASSEMBLY (DHS®/DCS® CENTERING SLEEVE AND DHS®/DCS® GUIDE SHAFT). DHS®/DCS® LAG SCREW 12.7 MM THREAD/95 MM (PART # 280.950, LOT # 5522496, QTY # 1) WAS ATTACHED TO THE GUIDE SHAFT AND COUPLING SCREW AND WAS NOT ABLE TO DETACH BECAUSE IT WAS STUCK INSIDE OF THE WRENCH. UPON TRYING TO DISCONNECT IT, THE HANDLE BROKE OFF THE DHS WRENCH. THE DHS®/DCS® COUPLING SCREW AND THE GUIDE SHAFT ASSEMBLY WERE REMOVED BY MOVING BACK AND FORTH. THERE WAS A SURGICAL DELAY OF 8-10 MINUTES. THE SURGERY WAS COMPLETED USING THE DYNAMIC HELICAL HIP SYSTEM (DHHS). THE PATIENT WAS UNHARMED. CONCOMITANT DEVICES REPORTED: DHS®/DCS® COUPLING SCREW (PART # 338.20, LOT # UNKNOWN, QTY #1) THIS IS REPORT 4 OF 4 FOR PC-(B)(4).

    Patient problems: No Code Available

    MAUDE report 7360152 ↗

FDA clearance and classification

Cleared through 510(k) K791619 on Aug 28, 1979 (decision: Substantially Equivalent). Submitted by Synthes (Usa) as “Dynamic Hip Screw”. The FDA review took 7 days. FDA record ↗

The FDA regulates product code KTT (appliance, fixation, nail/blade/plate combination, multiple component) under 21 CFR 888.3030 as a Class II device. 21 CFR 888.3030 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the DHS 280.950

Has the DHS 280.950 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10886982176332), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the DHS 280.950?

The FDA's MAUDE database lists 3 adverse event reports for this device, received between Mar 21, 2018 and Nov 15, 2022. In those reports, the most common specific device problem is “Device Operates Differently Than Expected” (1); the most common patient problem is “Necrosis” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the DHS 280.950?

None of the reports are classified as deaths, 3 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the DHS 280.950 FDA approved?

It was cleared through 510(k) K791619 on Aug 28, 1979. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the DHS 280.950 MRI safe?

According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.

Who makes the DHS 280.950, and is it still sold?

The FDA's device database lists Synthes GmbH as the company responsible for it (brand DHS, model 280.950). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT devices

All APPLIANCE, FIXATION, NAIL/BLADE/PLATE COMBINATION, MULTIPLE COMPONENT devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page