The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982182494), received between May 31, 2019 and Jun 4, 2019 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- No Consequences Or Impact To Patient1
- No Patient Involvement1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 4, 2019Break; Break
IT WAS REPORTED THAT ON (B)(6) 2019, A CABLE SNAPPED UNDER A MAXIMUM OF 40 KG TENSION. THE SECOND CABLE BEGAN FRAYING AT THE CRIMP BEFORE TENSION WAS ACHIEVED THEREFORE RENDERING IT UNUSABLE. BOTH CABLES WERE COMPLETELY REMOVED AND WERE REPLACED WITH NEW ONES. THERE WAS A SURGICAL DELAY OF TWO (2) MINUTES. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO PATIENT CONSEQUENCE. THIS COMPLAINT INVOLVES ONE (1) DEVICES. THIS REPORT IS 1 OF 1 FOR (B)(4).
Patient problems: No Patient Involvement
MAUDE report 8666941 ↗MalfunctionMay 31, 2019Break; Break
IT WAS REPORTED THAT ON (B)(6) 2019, THE SURGEON WAS TENSIONING A 1.0 MM CABLE DURING AN OPEN REDUCTION AND INTERNAL FIXATION (ORIF) OF HIP FRACTURE, THE CABLE WITH CRIMP BROKE. CABLE WAS REMOVED AND REPLACED WITH AN UNKNOWN 1.7 MM CABLE. IT IS UNKNOWN IF THERE WERE FRAGMENTS GENERATED. IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY. THE PROCEDURE WAS COMPLETED AND PATIENT STATUS IS UNKNOWN. CONCOMITANT DEVICE REPORTED: UNK - TENSIONING INSTRUMENTS: TRAUMA (PART # UNKNOWN, LOT # UNKNOWN, QUANTITY 1). THIS REPORT IS FOR ONE (1) 1.0 MM CABLE WITH CRIMP 750 MM-STERILE. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8659092 ↗
Other CERCLAGE, FIXATION devices
- ZipFix 03.501.080Synthes GmbH · CERCLAGE, FIXATION236 reports
- CONTROL 1739-28-000Depuy Orthopaedics, Inc. · CERCLAGE, FIXATION52 reports
- Dall-Miles 6704-0-110Howmedica Osteonics Corp. · CERCLAGE, FIXATION1 recall1 report
- Tritium® Sternal Cable Plate System 86-27-12-S12Pioneer Surgical Technology, Inc. · CERCLAGE, FIXATION1 recall0 reports
- Accord 71340007Smith & Nephew, Inc. · CERCLAGE, FIXATION47 reports
- ZipFix 08.501.001.01SSynthes GmbH · CERCLAGE, FIXATION39 reports
- NA 298.801.01SSynthes GmbH · CERCLAGE, FIXATION33 reports
- ZipFix 08.501.001.05SSynthes GmbH · CERCLAGE, FIXATION29 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page