NA 310.143Recalls & reported problems
Synthes GmbH · 1.5MM DRILL BIT STRYKER J-LATCH/75MM · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982186003), received between Mar 6, 2019 and Mar 6, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 6, 2019Break; Break
IT WAS REPORTED THAT ON AN UNKNOWN DATE, DURING CORONOID FRACTURE USING MODULAR HAND 2.0MM MODULE, THE DRILL BIT STRYKER BROKE. THE FLUTED PORTION OF THE DRILL WAS DISPOSED. THE SHAFT OF THE DRILL REMAINED IN THE STRYKER POWER ATTACHMENT. IT IS UNKNOWN IF THE DRILL BIT BROKE IN THE BONE OR BEFORE INSERTION INTO THE BONE. THE DRILL BIT WAS NOT USED IN TANDEM WITH A DRILL GUIDE WHICH MAY HAVE ALLOWED THE DRILL BIT TO DEFORM UNDER THE DRILLS HIGH REVOLUTION PER MINUTE (RPM). A NEW DRILL BIT WAS SELECTED TO FINISH THE PROCEDURE. FRAGMENTS WERE GENERATED FROM THE BROKEN DEVICE AND WERE REMOVED. THERE WAS A SURGICAL DELAY OF AN UNKNOWN DURATION. PROCEDURE WAS SUCCESSFULLY COMPLETED. PATIENT OUTCOME WAS AS EXPECTED. CONCOMITANT DEVICE REPORTED: UNKNOWN DRILL BIT (PART# UNKNOWN, LOT # UNKNOWN, QUANTITY 1), UNKNOWN MODULE (PART# UNKNOWN, LOT # UNKNOWN, QUANTITY 1). THIS REPORT IS FOR ONE (1) 1.5MM DRILL BIT STRYKER J-LATCH/75MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8394346 ↗
Other INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT devices
- NA 511.701Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT2,164 reports
- SmartLife 7126-120-000Stryker Corporation · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT1,065 reports
- NA 05.001.224Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT987 reports
- NA 05.001.206Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT632 reports
- NA 532.021Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT521 reports
- NA 2570-04-501Depuy (Ireland) · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT500 reports
- NA 532.110Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT433 reports
- NA 05.001.223Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT397 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page