Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982186119), received between Sep 5, 2025 and Sep 5, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Entrapment of Device1

Patient problems

  • Bone Notching1
  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 5, 2025Break; Entrapment of Device; Break; Entrapment of Device

    USER FACILITY REPORT RECEIVED (B)(4).IT WAS REPORTED THAT THE HCP HAD A PATIENT WITH A DISTAL TRICEPS TRAUMATIC RUPTURE. PATIENT WAS BROUGHT TO THE OPERATING ROOM. STANDARD FIXATION FOR THIS TYPE OF INJURY IS TO DRILL 2 PARALLEL TUNNELS THROUGH THE INSERTION POINT IN THE OLECRANON EXITING MORE DISTAL IN THE OLECRANON BONE AND REPAIRING THE TRICEPS WITH STITCHES AND A SECONDARY BACKUP CALLED A SWIVELOCK. SURGEON USED A 2 MM DRILL BIT, DRILLED THE 1ST HOLE WITHOUT ANY PROBLEM. WHILE DRILLING THE 2ND HOLE TRYING TO EXIT THE OUTER CORTEX THE DRILL BIT BROKE WHILE IN THE ULNA. INTRAOPERATIVE FLUOROSCOPY CONFIRMED THE INTRAMEDULLARY POSITION OF THE BROKEN DRILL BIT. THIS WAS NOT INTRA-ARTICULAR OR EXTRA-ARTICULAR. IT WAS INTRAMEDULLARY. THIS WAS THE APPROPRIATE POSITIONING OF THE DRILL HOLE. SURGEON ATTEMPTED TO RETRIEVE THE DRILL BIT WHICH WAS LODGED IN THE INTRAMEDULLARY CANAL OF THE ULNA BONE. MULTIPLE ATTEMPTS AT REMOVING THIS WITH INSTRUMENTS IN BOTH IN ANTEGRADE AND RETROGRADE FASHION WERE UNSUCCESSFUL. SURGEON TRIED CURETTING THE BONE AND RONGEURING THE BONE HOWEVER MY ATTEMPTS TO REMOVE THE BROKEN DRILL BIT JUST CREATED MORE BONY DESTRUCTION. IN ORDER TO REMOVE THIS BR

    Patient problems: Bone Notching; Foreign Body In Patient

    MAUDE report 22981687 ↗