NA 332.121Recalls & reported problems
Synthes GmbH · CANNULATED CHISEL FOR ADULT ANGLED BLADE PLATES 320MM · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10886982192561), received between Nov 10, 2020 and Jan 22, 2024 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Material Deformation” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Material Deformation5
- Corroded2
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 22, 2024Material Deformation; Material Deformation
THE NAIL REMOVAL SURGERY WAS BEING PERFORMED DUE TO A NON-UNION. THE HAMMER GUIDE THREADED INTO EXTRACTOR AND CROSS THREADED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18557177 ↗MalfunctionJun 30, 2021Corroded; Material Deformation; Corroded; Material Deformation
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE PATIENT UNDERWENT AN UNKNOWN SURGERY. DURING THE PROCEDURE, TWO DEPTH GAUGE TIPS WERE BENT AND BROKEN. EIGHT THREADED DRILL GUIDE, FOUR DRILL BIT, TWO END CAP, TWO CANNULATED CHISEL, TWO CHISEL GUIDE, AND LOCKING COMPRESSION PLATE (LCP) PROXIMAL HUMERUS PLATE HAD WERE INVOLVED IN THREADS STRIPPING VA LOCKING HOLES. CHISEL AND GUIDE WERE BENT DURING PROCESS OF INSERTION. NO FRAGMENTS WERE GENERATED. THERE WAS A SURGICAL DELAY OF FIVE MINUTES. PROCEDURE OUTCOME IS UNKNOWN. NO PATIENT CONSEQUENCE. THIS REPORT IS FOR (1) CANN CHISEL FOR ADULT ANGD BLADE PLS 320. THIS REPORT IS 6 OF 6 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12091752 ↗MalfunctionJun 21, 2021Corroded; Material Deformation; Corroded; Material Deformation
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE PATIENT UNDERWENT AN UNKNOWN SURGERY. DURING THE PROCEDURE, TWO DEPTH GAUGE TIPS WERE BENT AND BROKEN. EIGHT THREADED DRILL GUIDE, FOUR DRILL BIT, TWO END CAP, TWO CANNULATED CHISEL, TWO CHISEL GUIDE, AND LOCKING COMPRESSION PLATE (LCP) PROXIMAL HUMERUS PLATE HAD WERE INVOLVED IN THREADS STRIPPING VA LOCKING HOLES. CHISEL AND GUIDE WERE BENT DURING PROCESS OF INSERTION. NO FRAGMENTS WERE GENERATED. THERE WAS A SURGICAL DELAY OF FIVE MINUTES. PROCEDURE OUTCOME IS UNKNOWN. NO PATIENT CONSEQUENCE. THIS REPORT IS 1 OF 6 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12036472 ↗MalfunctionNov 10, 2020Material Deformation; Material Deformation
IT WAS REPORTED THAT ON (B)(6) 2020, PATIENT UNDERWENT AN OPEN REDUCTION INTERNAL FIXATION (ORIF) OF RIGHT FEMUR WITH ANGLE BLADE PLATES. DURING THE PROCEDURE, TWO (2) CANNULATED CHISELS FOR ADULT ANGLED BLADE PLATES WERE BENT. SURGERY WAS DELAYED FOR ABOUT FIVE (5) MINUTES. PROCEDURE WAS SUCCESSFULLY COMPLETED. PATIENT STATUS UNKNOWN. THIS REPORT IS FOR ONE (1) CANNULATED CHISEL FOR ADULT ANGLED BLADE PLATES 320MM. THIS IS REPORT 2 OF 2 FOR COMPLAINT (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10817624 ↗MalfunctionNov 10, 2020Material Deformation; Material Deformation
IT WAS REPORTED THAT ON (B)(6) 2020, PATIENT UNDERWENT AN OPEN REDUCTION INTERNAL FIXATION (ORIF) OF RIGHT FEMUR WITH ANGLE BLADE PLATES. DURING THE PROCEDURE, TWO (2) CANNULATED CHISELS FOR ADULT ANGLED BLADE PLATES WERE BENT. SURGERY WAS DELAYED FOR ABOUT FIVE (5) MINUTES. PROCEDURE WAS SUCCESSFULLY COMPLETED. PATIENT STATUS UNKNOWN. THIS REPORT IS FOR ONE (1) CANNULATED CHISEL FOR ADULT ANGLED BLADE PLATES 320MM. THIS IS REPORT 1 OF 2 FOR COMPLAINT (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10817621 ↗
FDA clearance and classification
The FDA regulates product code FZO (chisel, surgical, manual) under 21 CFR 878.4800 as a Class I device. 21 CFR 878.4800 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the NA 332.121
Has the NA 332.121 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10886982192561), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the NA 332.121?
The FDA's MAUDE database lists 5 adverse event reports for this device, received between Nov 10, 2020 and Jan 22, 2024. In those reports, the most common specific device problems are “Material Deformation” (5) and “Corroded” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the NA 332.121?
None of the reports are classified as deaths, 0 as injuries and 5 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the NA 332.121 FDA approved?
Devices of this type (product code FZO) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Synthes GmbH.
Who makes the NA 332.121, and is it still sold?
The FDA's device database lists Synthes GmbH as the company responsible for it (brand NA, model 332.121). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CHISEL, SURGICAL, MANUAL devices
- SIGMA 2024-85-000Depuy (Ireland) · CHISEL, SURGICAL, MANUAL63 reports
- NA 2421-01-000Depuy (Ireland) · CHISEL, SURGICAL, MANUAL36 reports
- NA 399.56Synthes GmbH · CHISEL, SURGICAL, MANUAL11 reports
- NA 399.55Synthes GmbH · CHISEL, SURGICAL, MANUAL10 reports
- T.L.I.F. 274279000Depuy Spine, LLC · CHISEL, SURGICAL, MANUAL7 reports
- INSTRUMENT 6541-4-709Howmedica Osteonics Corp. · CHISEL, SURGICAL, MANUAL4 reports
- NA 202953Depuy Spine, LLC · CHISEL, SURGICAL, MANUAL4 reports
- INTUITION 2525-50-000Depuy (Ireland) · CHISEL, SURGICAL, MANUAL3 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page