NA 456.307SRecalls & reported problems

Synthes GmbH · 11.0MM TI HELICAL BLADE 110MM-STERILE · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982226761), received between Jun 28, 2019 and Jun 28, 2019 — classified as 2 injuries.

The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).

7 other recalls cover devices cleared under the same FDA submission (K011857); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Device-Device Incompatibility2

Patient problems

  • No Code Available2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 28, 2019Device-Device Incompatibility; Device-Device Incompatibility

    IT IS UNKNOWN IF THE DEVICE FAILED. IT WAS USED IMPROPERLY AND COULD NOT BE LOCKED BECAUSE THE HELICAL BLADE WAS UPSIDE DOWN. THEREFORE, THIS CONSTRUCT COULD NOT HAVE WORKED AS IT WAS DESIGNED TO.

    Patient problems: No Code Available

    MAUDE report 8744235 ↗
  • InjuryJun 28, 2019Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT ON AN UNKNOWN DATE DURING A TROCHANTERIC FEMORAL NAIL (TFN), A 125 DEGREE NAIL WAS IMPLANTED IN THE PATIENT BUT THE DOCTOR DID NOT HAVE A 125 DEGREE HELICAL BLADE AIMING ARM SO A 130 DEGREE ARM WAS USED INSTEAD. THE HELICAL BLADE WAS LEFT UPSIDE DOWN IN THE PATIENT AND NAIL. THE NAIL COULD NOT BE LOCKED. IT IS UNKNOWN IF THERE WAS SURGICAL DELAY. PATIENT AND PROCEDURE OUTCOME ARE UNKNOWN. THIS IS REPORT 3 OF 3 FOR (B)(4). (B)(4) CAPTURES THE INTRA OPERATIVE TFN EVENT, FOR THE AIMING ARM AND NAIL THAT COULD NOT BE LOCKED WHILE (B)(4) CAPTURES THE POST OP EVENT WHERE THE TFN WAS REVISED DUE TO FAILED LOCKING MECHANISM.

    Patient problems: No Code Available

    MAUDE report 8744061 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K011857. One submission often covers many models, so check the product and lot details in each record.

  • Z-0604-2018 · Jul 21, 2017 · Terminated
    11MM/130 Degree Titanium Trochanteric Fixation Nail 380MM/Right, Sterile
  • Z-0375-2016 · Nov 2, 2015 · Terminated
    Trochanteric Fixation Nail- Advanced System-11MM/130 DEG TI CANN TFNA 420MM/Right Sterile (The TFN-ADVANCED Proximal Femoral Nailing System) The TFN-ADVANCED Proximal Femoral Naili
  • Z-0219-2015 · Oct 29, 2014 · Terminated
    10 mm/135 degree Titanium Cannulated Trochanteric Fixation Nail 170 MM - Sterile: intended to treat stable and unstable fractures of the proximal femur
  • Z-0387-2014 · Jul 31, 2013 · Terminated
    Large Buttress Compression Nut For Blade Guide Sleeve TFN The Synthes Large Buttress Compression Nut For Blade Guide Sleeve TFN is intended to treat stable and unstable pertrocha
  • Z-0452-2014 · Jul 30, 2013 · Terminated
    Titanium Trochanteric Fixation Nail (TFN)System Intended to treat stable and unstable fractures of the proximal femur.
  • Z-0474-2014 · Jul 30, 2013 · Terminated
    Synthes Trochanteric Fixation Nail As part of the Synthes Trochanteric Fixation Nail (TFN) System, the TFN Nail is intended to treat stable and unstable fractures of the proximal
  • Z-2058-2013 · Nov 2, 2012 · Terminated
    Synthes Trauma Nail System. The devices are indication for bone fixation.