NA 04.033.967SRecalls & reported problems
Synthes GmbH · 9 MM / TI CANN FRN / GT 360MM / LEFT - STERILE · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886982272331), received between Apr 29, 2022 and Apr 29, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Difficult to Advance” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Difficult to Advance1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 29, 2022Difficult to Advance; Difficult to Advance
IT WAS REPORTED ON (B)(6) 2022, DURING A ROUTINE FRN NAIL INSERTION, THE IM NAIL GOT STUCK IN THE CANAL OF THE FEMUR. THE CANAL 1.5MM REAMED OVER THE NAIL DIAMETER AND OPENED THE PROXIMAL SEGMENT WITH THE APPROPRIATE 14MM DRILL BIT FROM THE SET. THE NAIL BECAME INCARCERATED UPON INSERTION AND THE PROXIMAL BODY OF THE NAIL SEEMED TO BE TOO LONG FOR THE PROXIMAL SEGMENT OF THE FEMUR ON THIS PATIENT. THE DRIVING CAP BROKE OFF LEAVING A FRAGMENT IN THE INSERTION HANDLE DUE TO INCARCERATION THAT LED THE SURGEON TO HAVE TO STRIKE THE INSERTION HANDLE TO SEAT THE NAIL. THE SURGEON DETERMINED THAT THE NAIL WAS FINALLY SEATED TO A DEPTH AFTER A 30 MIN DELAY. STANDARD LOCKING OF THE PROXIMAL AND DISTAL NAIL OCCURRED WITHOUT INCIDENT. THIS REPORT IS FOR ONE (1) 9 / TI CANN FRN / GT 360 / LEFT - SILE. THIS IS REPORT 2 OF 2 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14254562 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page