The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10886982272362), received between Mar 31, 2020 and Jun 30, 2020 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Break1
Patient problems
- No Code Available2
- Discomfort1
- Failure of Implant1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJun 30, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
CONCOMITANT DEVICES REPORTED: UNKNOWN SCREWS (PART#UNKNOWN, LOT# UNKNOWN, QUANTITY# UNKNOWN).
Patient problems: Discomfort; No Code Available
MAUDE report 10214417 ↗InjuryMar 31, 2020Break; Break
IT WAS REPORTED THAT ON (B)(6) 2020, THE PATIENT UNDERWENT A HARDWARE REMOVAL DUE TO THE BROKEN GREATER TROCHANTER FEMORAL RECON NAIL (FRN). THE PATIENT WAS IMPLANTED WITH DEPUY SYNTHES FEMORAL RECON NAIL AND ZIMMER BIOMET NCB PLATE. THE REVISION SURGERY WAS COMPLETED SUCCESSFULLY. THIS REPORT CAPTURES THE REPORTED EVENT OF POSTOP NAIL BREAKAGE WHILE RELATED COMPLAINT (B)(4) CAPTURES THE INTRA-OP EVENT OF BROKEN SCREWDRIVER AND DRIVING CAP . CONCOMITANT DEVICES REPORTED: TI RECON SCREWS (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY UNKNOWN); LOCKING SCREW (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY UNKNOWN); END CAP (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY 1). THIS REPORT IS FOR ONE (1) 9MM/TI CANN FRN/GT 420MM/LEFT-STERILE. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: Failure of Implant; No Code Available
MAUDE report 9907551 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page