ICU Medical 14018-04Recalls & reported problems
Icu Medical, Inc. · Primary Plum Set, Single Channel Cassette, Secure Lock, 107 inch · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10887709101842), received between Feb 1, 2024 and Sep 16, 2026 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Contamination” (3 reports).
11 other recalls cover devices cleared under the same FDA submission (K141789); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Contamination3
- Crack1
- Fluid/Blood Leak1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 16, 2026Crack
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50794949 ↗MalfunctionJun 15, 2026Contamination
AN EVENT OCCURRED ON AN UNSPECIFIED EVENT DATE INVOLVING A IV TUBING SET REPORTED THAT THERE WAS A RANGE OF BLACK AND BROWN DOTS FOUND INSIDE THE DRIP CHAMBER AND ALSO FOUND INSIDE THE AREA WHERE THE DRIP CHAMBER WAS NARROWED INTO THE TUBING AS WELL AS THE SMALLER CHAMBER JUST ABOVE THE DRIP CHAMBER. THERE WAS NO PATIENT INVOLVEMENT AND NO HARM/ADVERSE EVENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25500231 ↗MalfunctionJun 15, 2026Contamination
THE EVENT OCCURRED ON AN UNSPECIFIED DATE INVOLVING A PRIMARY PLUM SET, SINGLE CHANNEL CASSETTE, SECURE LOCK, 107 INCH, AND IT WAS REPORTED THAT THERE WAS A RANGE OF BLACK AND BROWN DOTS FOUND INSIDE THE DRIP CHAMBER. THERE WAS NO PATIENT INVOLVEMENT, AND NO REPORTED PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25499138 ↗MalfunctionJun 15, 2026Contamination
THE EVENT OCCURRED ON AN UNSPECIFIED DATE INVOLVING A PRIMARY PLUM SET, SINGLE CHANNEL CASSETTE, SECURE LOCK, 107 INCH, AND IT WAS REPORTED THAT THERE WAS A RANGE OF BLACK AND BROWN DOTS FOUND INSIDE THE DRIP CHAMBER. THERE WAS NO REPORTED PATIENT INVOLVEMENT, AND NO REPORTED PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25499131 ↗MalfunctionFeb 1, 2024Fluid/Blood Leak; Fluid/Blood Leak
THE COMPLAINT/EVENT INVOLVED A PRIMARY PLUM SET, SINGLE CHANNEL CASSETTE, SECURE LOCK, 107 INCH. IT WAS REPORTED THAT THE FACILITY WAS HAVING ISSUES WITH LEAKING FROM THE DEVICE'S POP-OPEN VALVE NEAR THE TOP OF THE TUBING. THE TUBING SET UP WAS A STANDARD STERILE PROCEDURE/PROCESS FOR SPIKING THE TOTAL PARENTERAL NUTRITION (TPN) BAG AND CONNECTING THE IV FLUID/CONNECTORS TO THE PATIENT LINE. THE TUBING WAS REPLACED AND THEY NEEDED TO SWITCH TO AN ALTERNATE FLUID BECAUSE REPLACEMENT TPN COULD NOT BE MADE AT THE TIME.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18626467 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K141789. One submission often covers many models, so check the product and lot details in each record.
- Z-3162-2026 · May 12, 2026 · Open, ClassifiedIV Sets with drip chambers
- Z-2447-2024 · May 7, 2024 · Open, ClassifiedReplacement Battery List Number SUB0000864, found in Plum 360 Infusion System, List Number 30010. Product description is PLUM 360 Infuser. OUS units marketed with the following de
- Z-2430-2023 · Jul 13, 2023 · Open, ClassifiedPlum 360 Infusion System, List Numbers: 300100405, 300100409, 300100413, 300100414, 300100415, 300100418, 300100451, 300100452, 300100453, 300100481, 300100483, 300100613, 3001010
- Z-1565-2023 · Mar 22, 2023 · Open, ClassifiedReplacement Battery List Number SUB0000864, found in Plum 360 Infusion System, List Number 30010
- Z-0127-2020 · Jul 29, 2019 · TerminatedInfusion Pump I.V. Administration, specifically Plum Microbore Infusion Sets with Inline Filters labeled as Primary PLUM Set 0.2 Micron Filter, Prepierced Y-Site, Polyethylene Line
- Z-0128-2020 · Jul 29, 2019 · TerminatedInfusion Pump I.V. Administration, specifically Plum Microbore Infusion Sets with Inline Filters labeled as Primary PLUM Set Yellow Striped Tubing, Distal Microbore Tubing, 0.2 Mic
- Z-0145-2020 · Jul 29, 2019 · TerminatedInfusion Pump I.V. Administration, specifically Plum Microbore Infusion Sets with Inline Filters labeled as PLUM Epidural Set with NRFit Connector Yellow-Striped Tubing, Distal Mic
- Z-3031-2017 · Jun 15, 2017 · TerminatedPlum 360 Infusion System
- Z-1682-2017 · Dec 30, 2016 · TerminatedPlum 360 Infusion Pump, Software Version 15.02. The infusion pump is capable of delivering fluids for a variety of therapies such as parenteral, enteral, or epidural infusions
- Z-1832-2016 · Mar 25, 2016 · TerminatedThe Plum 360 is a large volume infuser capable of delivering fluids for a variety of therapies such as parenteral, enteral, or epidural infusions. The Plum 360 infuser can deliver
- Z-1833-2016 · Mar 25, 2016 · TerminatedThe Plum A+ is a dual-line volumetric infusion system designed to meet the growing demand for hospital-wide, as well as alternate site and home healthcare, standardization. With it
Other Set, administration, intravascular devices
- Autosoft XC 1001680Unomedical A/S · Set, Administration, Intravascular1 death16,105 reports
- Autosoft90™ 1002817Unomedical A/S · Set, Administration, Intravascular1 recall11,907 reports
- Minimed™ Quick-set™ MMT-399AUnomedical A/S · Set, Administration, Intravascular9 deaths8,669 reports
- Medtronic Extended MMT-431AUnomedical A/S · Set, Administration, Intravascular3 deaths8,574 reports
- MiniMed™ Mio™ Advance MMT-242AUnomedical A/S · Set, Administration, Intravascular15 deaths8,164 reports
- CADD 21-7302-24Icu Medical, Inc. · Set, administration, intravascular4 recalls1 death4,657 reports
- Autosoft XC 1001681Unomedical A/S · Set, Administration, Intravascular1 death4,216 reports
- Minimed™ Quick-set™ MMT-397AUnomedical A/S · Set, Administration, Intravascular19 deaths4,134 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page