Lifecare PCA 1427928Recalls & reported problems

ICU Medical, Inc. · Y-Type Minibore PCA Set, Integral PAV, Injector Assembly, Secure Lock, 86 Inch · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10887787005506), received between Mar 31, 2025 and Mar 31, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 31, 2025Fluid/Blood Leak; Fluid/Blood Leak

    THE EVENT OCCURRED ON AN UNSPECIFIED AND INVOLVED A Y-TYPE MINIBORE PCA SET, INTEGRAL PAV, INJECTOR ASSEMBLY, 0.2 MICRON FILTER, SECURE LOCK, 86 INCH WHERE THE CUSTOMER REPORTED THAT THE PCA LINE HOOKED UP TO THE PATIENT WAS LEAKING HYDROMORPHONE LEAKING. THE CUSTOMER INSPECTED THE TUBING AND FOUND IT TO HAVE A SPLIT IN IT NEAR THE VIAL AND PCA MACHINE. THE PCA LINE LINE WAS CHANGED OUT BUT HYDROMORPHONE VIAL REUSED. IMMEDIATE ACTION WAS DONE WHEN THEY REPLACED THE TUBING. THERE WAS PATIENT INVOLVEMENT, BUT HARM WAS NOT REPORTED AS A CONSEQUENCE OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21735011 ↗

Other Pump, infusion, pca devices

All Pump, infusion, pca devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.