Immucor Gti Diagnostics, Inc. · ThromboType assay is an assay for the molecular determination of HPA-1 (PlA), HPA-2 (Ko), HPA-3 (Bak), HPA-4 (Pen), HPA-5 (Br), HPA-6 (Ca), and HPA-15 (Gov), using PCR amplification of human genomic DNA. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10888234500285), received between Jun 29, 2018 and Jun 29, 2018 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device Ingredient or Reagent Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Device Ingredient or Reagent Problem1

Patient problems

  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 29, 2018Device Ingredient or Reagent Problem; Device Ingredient or Reagent Problem

    THROMBOTYPE LOT 3005154 (EXPIRATION DATE 08-15-2018) FAILED TO MEET TESTING SPECIFICATIONS DURING 15-MONTH STABILITY TESTING DUE TO WEAK AND/OR ABSENT BANDS IN THE HPA-1A AND HPA-3A SYSTEMS DURING THE INITIAL TESTING ON 05/30/2018. THE FAILURE MODE OBSERVED IN OOS 18-98 WAS CONFIRMED DURING REPEAT TESTING. OOS 18-98 WAS INITIATED TO INVESTIGATE WEAK AND/OR ABSENT BANDS IN THE HPA-1A AND HPA-3A SYSTEMS DURING REPEAT TESTING ON (B)(6) 2018. ALTERNATE SAMPLES WERE TESTED UNDER OOS 18-98, TO RULE OUT SAMPLE INTEGRITY. THE REPLACEMENT SAMPLES SHOWED WEAK/ABSENT BANDS FOR HPA-1A AND ABSENT BANDS FOR HPA-3A. THE FAILURES WERE ISOLATED TO THE HPA-1A AND HPA-3A SYSTEMS INDICATING THAT THE OTHER TEST KIT COMPONENTS ARE PERFORMING AS EXPECTED. THIS INDICATES POTENTIAL DEGRADATION OF THE HPA-1A AND HPA-3A PRIMERS. A REVIEW OF SIMILAR PRODUCTS IN THE FIELD IDENTIFIED THROMBOTYPE 1 LOTS 3006502 AND 3005160. THROMBOTYPE 1 LOT 3005160 WAS MANUFACTURED WITH THE SAME LOTS OF PRIMER RAW MATERIALS FOR THE HPA-1A SYSTEM. THE 18 MONTH STABILITY TIME POINT WAS COMPLETED ON 06/19/2018 AND ALL SPECIFICATIONS WERE MET. THEREFORE, THIS FAILURE APPEARS TO BE SPECIFIC TO THE MANUFACTURE OF THE THROMBOTYPE LOT

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7652289 ↗