Hu-Friedy UI25SD10Recalls & reported problems

Hu-Friedy Mfg. CO., LLC · 10 Swivel Direct Flow, 25K · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10889950075361), received between May 7, 2019 and May 7, 2019 — classified as 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • Foreign Body In Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 7, 2019Break; Break

    THE DENTAL HYGIENIST WAS USING THE ULTRASONIC INSTRUMENTATION FOR A ROUTINE PREVENTIVE CARE APPOINTMENT. THE PATIENT HAD A SLIGHTLY CLOSED MOUTH AND THOUGHT HE SWALLOWED CALCULOUS BUT, IT WAS THE INSTRUMENT TIP. THE PATIENT WAS SENT TO THE EMERGENCY ROOM FOR X-RAYS AND AN 8MM PART OF THE TIP WAS FOUND IN HIS STOMACH. PATIENT WAS ADVISED TO GO BACK TO ER IF HE HAD ANY ADDITIONAL STOMACH PAIN OR FEVER.

    Patient problems: Foreign Body In Patient

    MAUDE report 8588530 ↗

FDA clearance and classification

Cleared through Special 510(k) K012060 on Jul 27, 2001 (decision: Substantially Equivalent). Submitted by Hu-Friedy Mfg. Co., Inc. as “Modification To:Hu-Friedy Brand Satin Swivel Ultrasonic Insert”. The FDA review took 25 days. FDA record ↗

The FDA regulates product code ELC (scaler, ultrasonic) under 21 CFR 872.4850 as a Class II device. 21 CFR 872.4850 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Hu-Friedy UI25SD10

Has the Hu-Friedy UI25SD10 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10889950075361), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Hu-Friedy UI25SD10?

The FDA's MAUDE database lists 1 adverse event report for this device, received on May 7, 2019. That report lists device problem “Break” (1); patient problem “Foreign Body In Patient” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Hu-Friedy UI25SD10?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Hu-Friedy UI25SD10 FDA approved?

It was cleared through Special 510(k) K012060 on Jul 27, 2001. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Hu-Friedy UI25SD10, and is it still sold?

The FDA's device database lists Hu-Friedy Mfg. CO., LLC as the company responsible for it (brand Hu-Friedy, model UI25SD10). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Scaler, ultrasonic devices

All Scaler, ultrasonic devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page