Mariner 41-7540-1Recalls & reported problems
Seaspine Orthopedics Corporation · Solid Screw 7.50 x 40mm · Class 2 · Implant
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10889981068950), received between Sep 3, 2020 and Sep 3, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Mechanical Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Mechanical Problem1
Patient problems
- Patient Problem/Medical Problem1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 3, 2020Mechanical Problem; Mechanical Problem
THE PATIENT UNDERWENT SPINAL SURGERY ON (B)(6) 2020 CONSISTING OF SEASPINE'S MARINER PEDICLE SCREW SYSTEM. A REVISION SURGERY WAS PERFORMED ON (B)(6) 2020 TO CORRECT THE TRAJECTORY OF AN S1 SCREW (MFG REF (B)(4): 41-7540-1) THAT WAS REPORTED TO HAVE BEEN TOO LATERAL. DURING THE REVISION SURGERY, IT WAS DISCOVERED THAT THE SET SCREWS AT S1/S2 WERE LOOSE (MFG REF (B)(4): 41-1010). THE SURGEON COMPLETED THE REVISION SURGERY BY REPLACING AND REDIRECTING THE S1 SCREW AS PLANNED, REINSERTING THE SET SCREW, AND TIGHTENING THE REMAINING SET SCREWS.
Patient problems: Patient Problem/Medical Problem
MAUDE report 10491218 ↗
Other Orthosis, spinal pedicle fixation, for degenerative disc disease devices
- EXPEDIUM VERSE 199721000Medos International Sàrl · Orthosis, spinal pedicle fixation, for degenerative disc disease387 reports
- Sequoia® 3301-1Zimmer Spine, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease184 reports
- CD HORIZON® Spinal System 8590855Medtronic Sofamor Danek, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease179 reports
- Vitality® 07.02011.001Biomet Spine LLC · Orthosis, spinal pedicle fixation, for degenerative disc disease3 recalls0 reports
- EXPEDIUM VERSE 199721001SMedos International Sàrl · Thoracolumbosacral pedicle screw system124 reports
- LineSider LS-N6SA7550Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls1 report
- LineSider LS-N6SA6545Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls0 reports
- EXPEDIUM VERSE 199721000SMedos International Sàrl · Thoracolumbosacral pedicle screw system97 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.