RUSCH IPN048573Recalls & reported problems
Teleflex Incorporated · RUSCH GREENLED HANDLE: MEDIUM · Class 1
All models of RUSCH (219)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 14026704625656), received between Mar 23, 2021 and Aug 9, 2022 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Optical Problem” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Optical Problem5
- Continuous Firing1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Insufficient Information2
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 9, 2022Continuous Firing; Continuous Firing
IT WAS REPORTED THAT: "THE LIGHT WAS FLICKERING DURING INTUBATION".
Patient problems: Insufficient Information
MAUDE report 15192813 ↗MalfunctionJun 28, 2022Optical Problem; Optical Problem
IT WAS REPORTED THAT "THE LIGHT OF THE HANDLE WAS FLICKERING". NO PATIENT INVOLVEMENT REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14842977 ↗MalfunctionMar 25, 2022Optical Problem; Optical Problem
IT WAS REPORTED THAT "THE LIGHT OF THE HANDLES ALWAYS STARTS TO FLICKER DURING INTUBATION, SO THE HANDLE HAD TO BE CHANGED AGAIN AND AGAIN. AFTER USE, THE HANDLE WAS CHECKED AND THE BATTERIES REMOVED. THE FIRST BATTERY INSERTED INTO PRODUCT WAS DEFORMED ON BEHALF OF THE PRODUCT, WHICH WAS NOT THE CASE BEFORE INSERTION OF THE BATTERY INTO THE HANDLE". MULTIPLE ATTEMPTS FOR ADDITIONAL INFORMATION TO THE CUSTOMER HAS BEEN UNSUCCESSFUL. PATIENT CONDITION UNKNOWN AT TIME OF REPORT.
Patient problems: Insufficient Information
MAUDE report 13906296 ↗MalfunctionMar 22, 2022Optical Problem; Optical Problem
IT WAS REPORTED THAT "THE LIGHT OF THE HANDLES ALWAYS STARTS TO FLICKER DURING INTUBATION, SO THE HANDLE HAD TO BE CHANGED AGAIN AND AGAIN. AFTER USE, THE HANDLE WAS CHECKED AND THE BATTERIES REMOVED. THE FIRST BATTERY INSERTED INTO PRODUCT WAS DEFORMED ON BEHALF OF THE PRODUCT, WHICH WAS NOT THE CASE BEFORE INSERTION OF THE BATTERY INTO THE HANDLE". NO PATIENT INJURY OR HARM REPORTED. PATIENT CONDITION REPORTED AS "FINE".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13846495 ↗MalfunctionNov 12, 2021Optical Problem; Optical Problem
IT WAS REPORTED "SEVERAL ANAESTHETISTS EXPERIENCED "FALSE CONTACT" ISSUES WHEN USING LARYNGOSCOPES WITH A BLINKING LIGHT DURING INTU BATION". NO PATIENT INJURY OR HARM REPORTED. PATIENT CONDITION REPORTED AS "FINE".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12807723 ↗MalfunctionMar 23, 2021Optical Problem; Optical Problem
IT WAS REPORTED "THE LIGHT FLICKERS WHEN THE HANDLE AND BLADE ARE CONNECTED PROPERLY. IT CAN BE EXCLUDED THAT THE FAULT IS WITH THE BLADE AS THE BLADE WAS TESTED WITH OTHER RUSCH GREENLED HANDLES AND WITH THESE IT WORKED WELL".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11558457 ↗
FDA clearance and classification
The FDA regulates product code CCW (laryngoscope, rigid) under 21 CFR 868.5540 as a Class I device. 21 CFR 868.5540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the RUSCH IPN048573
Has the RUSCH IPN048573 been recalled?
No FDA recall record in our data names this exact device identifier (DI 14026704625656), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the RUSCH IPN048573?
The FDA's MAUDE database lists 6 adverse event reports for this device, received between Mar 23, 2021 and Aug 9, 2022. In those reports, the most common specific device problems are “Optical Problem” (5) and “Continuous Firing” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the RUSCH IPN048573?
None of the reports are classified as deaths, 0 as injuries and 6 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the RUSCH IPN048573 FDA approved?
Devices of this type (product code CCW) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Teleflex Incorporated.
Is the RUSCH IPN048573 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Unsafe: it should not be taken into an MRI scanner room.
Who makes the RUSCH IPN048573, and is it still sold?
The FDA's device database lists Teleflex Incorporated as the company responsible for it (brand RUSCH, model IPN048573). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other LARYNGOSCOPE, RIGID devices
- McGRATH MAC 301-000-000Covidien LP · LARYNGOSCOPE, RIGID2 recalls201 reports
- McGRATH MAC 300-000-000Covidien LP · LARYNGOSCOPE, RIGID1 recall1 death203 reports
- n.a. 8404HXKarl Storz GmbH & Co. KG · LARYNGOSCOPE, RIGID235 reports
- McGRATH 340-000-000Covidien LP · LARYNGOSCOPE, RIGID2 deaths194 reports
- McGRATH MAC 301-000-000Covidien LP · LARYNGOSCOPE, RIGID2 recalls90 reports
- n.a. 8404BXCKarl Storz GmbH & Co. KG · LARYNGOSCOPE, RIGID132 reports
- n/a 8404AXCKarl Storz GmbH & Co. KG · LARYNGOSCOPE, RIGID94 reports
- McGRATH 340-000-000Covidien LP · LARYNGOSCOPE, RIGID84 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.