Tuohy 1150-6K091Recalls & reported problems
Pajunk GmbH Medizintechnologie · Tuohy with spec.Point,1cm grad. 18G x 3 1/2" (90mm), plastic stylet · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 14048223004019), received between May 20, 2020 and Aug 6, 2020 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
- Loss of or Failure to Bond1
Patient problems
- No Known Impact Or Consequence To Patient2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 6, 2020Break; Break
IRN#: (B)(4). BROKEN HUB.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 10374695 ↗MalfunctionMay 20, 2020Loss of or Failure to Bond; Loss of or Failure to Bond
IRN#: (B)(4). TENTATIVE TRANSLATION OF INITIAL REPORTER´S NARRATIVE: WHEN THE CANNULA WAS REMOVED, THE COMPLETE HUB CAME OFF. THE CANNULA TUBE HAD TO BE REMOVED WITH A NEEDLE HOLDER.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10073554 ↗
FDA clearance and classification
Cleared through 510(k) K040965 on Sep 7, 2004 (decision: Substantially Equivalent). Submitted by Pajunk GmbH as “Pajunk Tuohy Needles, Quincke Needles, Chiba Needles & Crawford Needles”. The FDA review took 146 days. FDA record ↗
The FDA regulates product code BSP (needle, conduction, anesthetic (w/wo introducer)) under 21 CFR 868.5150 as a Class II device. 21 CFR 868.5150 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Tuohy 1150-6K091
Has the Tuohy 1150-6K091 been recalled?
No FDA recall record in our data names this exact device identifier (DI 14048223004019), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Tuohy 1150-6K091?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between May 20, 2020 and Aug 6, 2020. In those reports, the most common specific device problems are “Break” (1) and “Loss of or Failure to Bond” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Tuohy 1150-6K091?
None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Tuohy 1150-6K091 FDA approved?
It was cleared through 510(k) K040965 on Sep 7, 2004. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the Tuohy 1150-6K091 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Unsafe: it should not be taken into an MRI scanner room.
Who makes the Tuohy 1150-6K091, and is it still sold?
The FDA's device database lists Pajunk GmbH Medizintechnologie as the company responsible for it (brand Tuohy, model 1150-6K091). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER) devices
- ARROW IPN922632Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)2 recalls0 reports
- ARROW IPN922605Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN922603Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN922604Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN922631Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN923597Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- 22G 1 1/2IN Regional Block Needle 408348Becton, Dickinson And Company · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- BD QUINCKE Spinal Needles 405180Becton, Dickinson And Company · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)23 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page