Bivona FT15LN90NSC861NRecalls & reported problems

Icu Medical, Inc. · Class 2

All models of Bivona (469)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 15019517035322), received between Mar 23, 2017 and Mar 9, 2026 — classified as 4 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Defective Device” (2 reports).

1 other recall cover devices cleared under the same FDA submission (K923878); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Defective Device2
  • Inflation Problem2
  • Device Operates Differently Than Expected1
  • Gas/Air Leak1
  • Infusion or Flow Problem1
  • Material Puncture/Hole1
  • Material Too Rigid or Stiff1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Respiratory Distress2
  • Cyanosis1
  • Extubate1
  • Patient Problem/Medical Problem1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 9, 2026Inflation Problem

    IT WAS REPORTED THAT THE CUFF INFLATION WAS ASYMMETRICAL. THERE WAS NO REPORTED PATIENT INVOLVEMENT, AND THERE WAS NO REPORTED PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24545382 ↗
  • InjuryOct 19, 2023Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT THE PATIENTS MOTHER CALLED IN STATING THAT "THE BALLOON ON THE TRACH WAS NOT INFLATING CORRECTLY". THE TRACH WAS REMOVED AND A NEW TRACH WAS PLACED. NO ADVERSE PATIENT EFFECTS WERE REPORTED BY THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17966614 ↗
  • InjuryMay 5, 2023Defective Device; Gas/Air Leak; Defective Device; Gas/Air Leak

    ADDITIONAL INFORMATION WAS RECEIVED: EVENT OCCURRED AT PATIENTS HOME. DEFECTIVE TRACH CUFF WAS IN USE AT THE TIME OF DISCOVERY. VENTILATOR WAS ALARMING AND AIR LEAK WAS NOTED. THERE WAS NO PATIENT INJURY. THERE WAS NO ADDITIONAL MEDICAL INTERVENTION. TRACH WAS CHANGED OUT IMMEDIATELY. TRACH TUBE WAS REPLACED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16878193 ↗
  • MalfunctionJul 15, 2022Material Puncture/Hole; Material Puncture/Hole

    IT WAS REPORTED THAT THE PILOT BALLOON HAD A HOLE IN IT CAUSING THE BALLOON NOT TO INFLATE. NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15032441 ↗
  • InjuryJun 5, 2017Material Too Rigid or Stiff; Device Operates Differently Than Expected; Material Too Rigid or Stiff; Device Operates Differently Than Expected

    IT WAS REPORTED THAT A PORTEX® BIVONA® CUSTOM TRACHEOSTOMY TUBE WAS NARROW AND STUFF, AND THE PATIENT EXPERIENCED RESPIRATORY DISTRESS. THE INCIDENT OCCURRED SHORTLY AFTER PLACEMENT. AIR WAS USED TO FILL THE CUFF. THE PATIENT COULD NOT MOVE AIR AND BECAME "DUSKY" AND BLUE, AND WAS EXPERIENCING RESPIRATORY DISTRESS. THE TRACHEOSTOMY TUBE WAS REPLACED WITH THE ONE THAT HAD JUST BEEN REMOVED. THE PATIENT CONSULTED WITH THEIR HEALTHCARE PROVIDER REGARDING THE INCIDENT. NO PERMANENT INJURY WAS REPORTED.

    Patient problems: Cyanosis; Respiratory Distress

    MAUDE report 6612274 ↗
  • InjuryMar 23, 2017Defective Device; Infusion or Flow Problem; Defective Device; Infusion or Flow Problem

    IT WAS REPORTED THAT A PORTEX® BIVONA® CUSTOM ADULT TRACHEOSTOMY TUBE WAS DEFECTIVE AND POSSIBLY CAUSED AIRFLOW RESTRICTION DURING USE WITH A PATIENT. THE DEVICE WAS INSERTED IN THE PATIENT WHEN THE PATIENT WAS IN RESPIRATORY DISTRESS. THE CUFF PATENCY WAS TESTED BY THE PATIENT'S MOTHER PRIOR TO USE. THE CUFF WAS FILLED WITH AIR. AN EMERGENCY TRACHEOSTOMY TUBE CHANGE WAS CONDUCTED, WHICH WAS REPORTED TO HAVE RESOLVED THE ISSUE. NO PERMANENT INJURY WAS REPORTED.

    Patient problems: Extubate; Patient Problem/Medical Problem; Respiratory Distress

    MAUDE report 6427390 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K923878. One submission often covers many models, so check the product and lot details in each record.

  • Z-0260-2007 · Nov 17, 2006 · Terminated
    Custom 5.5 mm Bivona Uncuffed Hyperflex Tracheostomy Tube, I.D. 5.5 mm, O.D. 8.0 mm, length 4.75 mm, Mfrd by Smiths Medical Critical Care; REF HU05JS55NNA112S.

Other Tube tracheostomy and tube cuff devices

All Tube tracheostomy and tube cuff devices →