Bivona XT23GS60NGC212NRecalls & reported problems
Icu Medical, Inc. · Class 2
All models of Bivona (469)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 15019517393491), received between Nov 11, 2024 and Nov 11, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Physical Resistance/Sticking” (1 report).
1 other recall cover devices cleared under the same FDA submission (K923878); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Physical Resistance/Sticking1
Patient problems
- Hemorrhage/Blood Loss/Bleeding1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 11, 2024Physical Resistance/Sticking; Physical Resistance/Sticking
IT WAS REPORTED THAT DURING TRACH CARE, AN OVERFILL OF THE TRAIN BALLOON WAS NOTED AND WHILE EXTRACTING WATER FROM THE PILOT BALLOON, IT HAD MORE RESISTANCE THAN NORMAL AND WAS SLOW TO EXTRACT. THE BALLOON WOULD BE COMPLETELY COMPRESSED AND REFILL AFTER WAITING. FILLING WATER IN PILOT BALLOON HAD RESISTANCE AND PILOT BALLOON WAS NOTED TO BE LOPSIDED DURING FILL AND TRACH ITSELF WAS LOPSIDED. BOTH WERE MANIPULATED TO FORM SYMMETRICAL SHAPE. THERE WAS MEDICAL INTERVENTION REQUIRED, AND THE OUTCOME OF THE INJURY (BLEEDING FROM AIRWAY) WAS RESOLVED BY ON (B)(6) 2024. THE ISSUE WAS RESOLVED BY CHANGING OUT THE TRACH FOR VISIBLE TESTING. THERE WAS PATIENT INVOLVEMENT, WITH INJURY AND NO DEATH EVENT REPORTED.
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 20651360 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K923878. One submission often covers many models, so check the product and lot details in each record.
- Z-0260-2007 · Nov 17, 2006 · TerminatedCustom 5.5 mm Bivona Uncuffed Hyperflex Tracheostomy Tube, I.D. 5.5 mm, O.D. 8.0 mm, length 4.75 mm, Mfrd by Smiths Medical Critical Care; REF HU05JS55NNA112S.
Other Tube tracheostomy and tube cuff devices
- Shiley 8CN85HCovidien LP · Tube tracheostomy and tube cuff1 recall2 deaths354 reports
- Shiley 6CN75HCovidien LP · Tube tracheostomy and tube cuff1 recall3 deaths240 reports
- Shiley 7CN80RCovidien LP · Tube tracheostomy and tube cuff2 recalls148 reports
- Bivona 67PFSS35Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall166 reports
- Bivona 670180Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall140 reports
- Bivona 670170Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall10 deaths132 reports
- Shiley 6CN75RCovidien LP · Tube tracheostomy and tube cuff1 recall1 death121 reports
- Bivona 67PFSS40Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall115 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page