1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 15021312000238), received between Sep 13, 2022 and Aug 29, 2023 — classified as 9 malfunctions.
The most frequently reported specific device problem is “Inflation Problem” (7 reports).
1 FDA recall record name this device's identifier, 1 still open.
5 other recalls cover devices cleared under the same FDA submission (K083641, K914088); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Recalls naming this device
- May 29, 2024Open, Classified
Smiths Medical has identified that the securement flange of specific lots of the Bivona Neonatal/Pediatric and Adult Tracheostomy products may tear because of a manufacturing defect.
Z-2615-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Inflation Problem7
- Leak/Splash2
Patient problems
- No Clinical Signs, Symptoms or Conditions9
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 29, 2023Inflation Problem; Inflation Problem
IT WAS REPORTED THAT DURING PRE-TESTING THE BALLOON WAS NOT INFLATING. THE DEVICE WAS BEING PREPPED FOR A NEWBORN BABY. THE EVENT DID NOT AFFECT PATIENT CARE. NO INJURY OR ADVERSE EFFECTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17647612 ↗MalfunctionAug 29, 2023Inflation Problem; Inflation Problem
IT WAS REPORTED THAT DURING PRE-TESTING THE BALLOON WAS NOT INFLATING. THE DEVICE WAS BEING PREPPED FOR A NEWBORN BABY. THE EVENT DID NOT AFFECT PATIENT CARE. NO INJURY OR ADVERSE EFFECTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17647583 ↗MalfunctionAug 29, 2023Inflation Problem; Inflation Problem
IT WAS REPORTED THAT DURING PRE-TESTING THE BALLOON WAS NOT INFLATING. THE DEVICE WAS BEING PREPPED FOR A NEWBORN BABY. THE EVENT DID NOT AFFECT PATIENT CARE. NO INJURY OR ADVERSE EFFECTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17647582 ↗MalfunctionFeb 23, 2023Inflation Problem; Inflation Problem
IT WAS REPORTED THAT THE TRACHS FOUND IN INVENTORY ARE NOT INFLATING. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16432928 ↗MalfunctionFeb 23, 2023Inflation Problem; Inflation Problem
IT WAS REPORTED THAT THE TRACHS FOUND IN INVENTORY ARE NOT INFLATING. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16429547 ↗MalfunctionSep 13, 2022Leak/Splash; Leak/Splash
IT WAS REPORTED THAT THE DEVICE FOUND IN INVENTORY IS NOT INFLATING. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15410611 ↗MalfunctionSep 13, 2022Leak/Splash; Leak/Splash
IT WAS REPORTED THAT THE DEVICE FOUND IN INVENTORY IS NOT INFLATING. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15410463 ↗MalfunctionSep 13, 2022Inflation Problem; Inflation Problem
IT WAS REPORTED THAT THE TRACHS FOUND IN INVENTORY ARE NOT INFLATING. NO PATIENT INJURY REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15410422 ↗MalfunctionSep 13, 2022Inflation Problem; Inflation Problem
IT WAS REPORTED THAT THE TRACHS FOUND IN INVENTORY ARE NOT INFLATING. NO PATIENT INJURY REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15410418 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K083641, K914088. One submission often covers many models, so check the product and lot details in each record.
- Z-0205-2024 · Aug 22, 2023 · Open, ClassifiedSmiths Medical Portex Bivona Pediatric Tracheostomy Tube, Cuffless, Model 60P045, Sterile.
- Z-2946-2020 · Aug 28, 2020 · TerminatedBivona Mid-Range Aire-Cuf Adult Tracheostomy Tube This tube is intended to provide direct airway access for a tracheotomized patient for up to 29 days. It may be reprocessed up to
- Z-1465-2017 · Feb 9, 2017 · TerminatedBivona TTS (Tight to Shaft) Pediatric Tracheostomy Tube, Model No. 67SP035, Reorder No. 67SP035.
- Z-0930-05 · Apr 26, 2005 · TerminatedBivona brand Pediatric TTS Tracheostomy Tube, 3.5 mm tracheostomy tubes with a 3.5mm obturator ; product code 67P035.
- Z-0302-06 · Feb 17, 2005 · TerminatedBivona brand Neonatal TTS Tracheostomy Tubes, sterile, product code 67N040.
Other Tube tracheostomy and tube cuff devices
- Shiley 8CN85HCovidien LP · Tube tracheostomy and tube cuff1 recall2 deaths354 reports
- Shiley 6CN75HCovidien LP · Tube tracheostomy and tube cuff1 recall3 deaths240 reports
- Shiley 7CN80RCovidien LP · Tube tracheostomy and tube cuff2 recalls148 reports
- Bivona 67PFSS35Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall166 reports
- Bivona 670180Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall140 reports
- Bivona 670170Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall10 deaths132 reports
- Shiley 6CN75RCovidien LP · Tube tracheostomy and tube cuff1 recall1 death121 reports
- Bivona 67PFSS40Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall115 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page