Bivona 67SP045Recalls & reported problems

Icu Medical, Inc. · Class 2

All models of Bivona (469)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This is a Bivona 67SP045 tracheostomy tube with a cuff, made by ICU Medical. Most of the 47 reports describe the cuff not inflating evenly, staying detached or disconnected, or the flange tearing;19 reports involved injuries and no deaths. One open recall, started in May 2024, covers certain lots whose securement flange can tear because of a manufacturing defect.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
47
Deaths reported
0
Injuries reported
19
Recalls naming it
1

Summary

The FDA's MAUDE database contains 47 adverse event reports that list this exact device (DI 15021312000733), received between Oct 25, 2019 and Oct 15, 2025 — classified as 19 injuries, 28 malfunctions.

The most frequently reported specific device problem is “Inflation Problem” (22 reports).

1 FDA recall record name this device's identifier, 1 still open.

5 other recalls cover devices cleared under the same FDA submission (K083641, K914088); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 1 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. May 29, 2024Open, Classified

    Smiths Medical has identified that the securement flange of specific lots of the Bivona Neonatal/Pediatric and Adult Tracheostomy products may tear because of a manufacturing defect.

    Z-2615-2024 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported problems

Device problems

  • Inflation Problem22
  • Detachment of Device or Device Component12
  • Disconnection12
  • Nonstandard Device3
  • Fracture2
  • Stretched2
  • Defective Device1
  • Deflation Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions26
  • No Code Available12
  • No Consequences Or Impact To Patient7
  • No Information3
  • Insufficient Information2
  • No Patient Involvement1

Recent adverse event reports

The 25 most recent of 47 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 15, 2025Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT THE CUFF WAS NOT INFLATING EVENLY. THE EVENT OCCURRED DURING PRE-TEST AT THE HOSPITAL. THE OPERATOR OF THE DEVICE WAS A HEALTH PROFESSIONAL. THEY DID NOT USE THE DEFECTIVE PRODUCT AND OPENED A NEW ONE WITH NO ISSUE. THIS IS AN OUT OF BOX FAILURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23289786 ↗
  • MalfunctionMay 12, 2025Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT THE CUFF DID NOT INFLATE EVENLY. THERE WERE NO PATIENT HARM OR ADVERSE EVENTS REPORTED AS A RESULT OF THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22002622 ↗
  • MalfunctionMar 6, 2025Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT THE CUFF DID NOT INFLATE EVENLY. THERE WERE NO PATIENT HARM OR ADVERSE EVENTS REPORTED AS A RESULT OF THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21532933 ↗
  • MalfunctionFeb 20, 2025Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT DURING PRETESTING OF THE TRACH TUBE THE RESPIRATORY THERAPISTS INDICATED THAT THE TUBE ONLY INFLATED ON ONE SIDE DESPITE MULTIPLE ATTEMPTS TO INFLATE IT UNIFORMLY. THERE WAS NO MEDICAL INTERVENTION REQUIRED. THERE WERE NO INJURIES OR ADVERSE EVENTS REPORTED AS A RESULT OF THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21428452 ↗
  • MalfunctionJan 14, 2025Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT DURING A TRACH CHANGE, THE CUFF WOULD NOT INFLATE. THERE WAS UNKNOWN PATIENT INVOLVEMENT AND UNKNOWN PATIENT HARM/ADVERSE EVENT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21150372 ↗
  • MalfunctionJul 11, 2023Stretched; Stretched

    IT WAS REPORTED THAT PRIOR TO USE, THE CUFF WAS TESTED AND FOUND TO BE NOT SYMMETRICAL. CUSTOMER STATES THIS COULD CAUSE PRESSURE TO THE TRACHEA. THE DEVICE WAS NOT USED ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17303251 ↗
  • MalfunctionJul 11, 2023Stretched; Stretched

    IT WAS REPORTED THAT PRIOR TO USE, THE CUFF WAS TESTED AND FOUND TO BE NOT SYMMETRICAL. CUSTOMER STATES THIS COULD CAUSE PRESSURE TO THE TRACHEA. THE DEVICE WAS NOT USED ON THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17303247 ↗
  • MalfunctionNov 7, 2022Nonstandard Device; Nonstandard Device

    IT WAS REPORTED THAT THE CUFF WAS CHECKED BEFORE USE, BUT IT WAS NOT SYMMETRICAL CAUSING PRESSURE ON THE PATIENT'S TRACHEA. ADDITIONAL INFORMATION WAS RECEIVED VIA CUSTOMER RESPONSE EMAIL 19-OCT-2022: ALL TUBES WERE CHECKED PRIOR TO PATIENT USE. NO MEDICAL INTERVENTION WAS REQUIRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15742205 ↗
  • MalfunctionNov 4, 2022Nonstandard Device; Nonstandard Device

    IT WAS REPORTED THAT THE CUFF WAS CHECKED BEFORE USE, BUT IT WAS NOT SYMMETRICAL CAUSING PRESSURE ON THE PATIENT'S TRACHEA. ADDITIONAL INFORMATION WAS RECEIVED VIA CUSTOMER RESPONSE EMAIL 19-OCT-2022: ALL TUBES WERE CHECKED PRIOR TO PATIENT USE. NO MEDICAL INTERVENTION WAS REQUIRED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15736439 ↗
  • MalfunctionNov 4, 2022Nonstandard Device; Nonstandard Device

    IT WAS REPORTED THAT THE CUFF WAS CHECKED BEFORE PATIENT USE, IT WAS NOT SYMMETRICAL, AND APPLIED PRESSURE TO THE PATIENTS TRACHEA. NO MEDICAL INTERVENTION WAS REQUIRED. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15735777 ↗
  • MalfunctionSep 26, 2022Failure to Unfold or Unwrap; Failure to Unfold or Unwrap

    IT WAS REPORTED THE DEVICE HAD A DEFECTIVE BALLOON. NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15486233 ↗
  • MalfunctionSep 22, 2022Defective Device; Defective Device

    IT WAS REPORTED THAT THE FOUR CUFFS WERE NOT INFLATING SYMMETRICALLY WITH HALF THE CUFF STICKING TO THE TUBE. NO PATIENT INJURY WAS REPORTED

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15466893 ↗
  • MalfunctionSep 19, 2022Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT THE CUFF NOT EVENLY INFLATING. CUFF IS STICKING TO THE PLASTIC MOLDED CONTAINER. NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15446493 ↗
  • MalfunctionSep 15, 2022Volume Accuracy Problem; Volume Accuracy Problem

    IT WAS REPORTED THAT THE DEVICE WAS STICKING TO ONE SIDE OF THE TUBE AND WOULD INFLATE ASYMMETRICALLY. THE ISSUE WAS RESOLVED WHEN ATTEMPTED AGAIN BUT WAS NOT USE ON PATIENT DUE TO THE MALFUNCTION. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15433482 ↗
  • MalfunctionSep 14, 2022Deflation Problem; Deflation Problem

    IT WAS REPORTED THAT DURING PRE-TEST, THE CUFF INFLATED ASYMMETRICALLY. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15417500 ↗
  • MalfunctionSep 14, 2022Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT DURING PRE-TEST, THE CUFF INFLATED ASYMMETRICALLY. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15417468 ↗
  • MalfunctionSep 14, 2022Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT DURING PRE-TEST, THE CUFF INFLATED ASYMMETRICALLY. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15417429 ↗
  • MalfunctionSep 14, 2022Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT THE DEVICE WAS NOT INFLATING SYMMETRICALLY. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15417428 ↗
  • MalfunctionSep 14, 2022Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT THE DEVICE WAS NOT INFLATING SYMMETRICALLY. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15417379 ↗
  • MalfunctionSep 14, 2022Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT THE DEVICE WAS NOT INFLATING SYMMETRICALLY. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15417378 ↗
  • MalfunctionSep 13, 2022Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT FOUR CUFFS WERE NOT INFLATING SYMMETRICALLY WITH HALF THE CUFF STICKING TO THE TUBE. NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15414825 ↗
  • MalfunctionSep 13, 2022Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT FOUR CUFFS WERE NOT INFLATING SYMMETRICALLY WITH HALF THE CUFF STICKING TO THE TUBE. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15414809 ↗
  • MalfunctionSep 13, 2022Inflation Problem; Inflation Problem

    IT WAS REPORTED THAT FOUR CUFFS WERE NOT INFLATING SYMMETRICALLY WITH HALF THE CUFF STICKING TO THE TUBE. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15414804 ↗
  • MalfunctionSep 13, 2022Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT DURING PRE-TESTING OF A NEW DEVICE, IT WAS FOUND THAT IT WAS NOT INFLATING FULLY DESPITE MANIPULATIONS. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15410647 ↗
  • MalfunctionOct 30, 2021Inflation Problem; Inflation Problem

    CUSTOMER REPORTS AN ISSUE WITH THE CUFF WHICH DOES NOT INFLATE EVENLY.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 12725073 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K083641, K914088. One submission often covers many models, so check the product and lot details in each record.

  • Z-0205-2024 · Aug 22, 2023 · Open, Classified
    Smiths Medical Portex Bivona Pediatric Tracheostomy Tube, Cuffless, Model 60P045, Sterile.
  • Z-2946-2020 · Aug 28, 2020 · Terminated
    Bivona Mid-Range Aire-Cuf Adult Tracheostomy Tube This tube is intended to provide direct airway access for a tracheotomized patient for up to 29 days. It may be reprocessed up to
  • Z-1465-2017 · Feb 9, 2017 · Terminated
    Bivona TTS (Tight to Shaft) Pediatric Tracheostomy Tube, Model No. 67SP035, Reorder No. 67SP035.
  • Z-0930-05 · Apr 26, 2005 · Terminated
    Bivona brand Pediatric TTS Tracheostomy Tube, 3.5 mm tracheostomy tubes with a 3.5mm obturator ; product code 67P035.
  • Z-0302-06 · Feb 17, 2005 · Terminated
    Bivona brand Neonatal TTS Tracheostomy Tubes, sterile, product code 67N040.

Other Tube tracheostomy and tube cuff devices

All Tube tracheostomy and tube cuff devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page