Bivona 60A150Recalls & reported problems
Icu Medical, Inc. · Class 2
All models of Bivona (469)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 15021312005547), received between Oct 25, 2023 and Oct 25, 2023 — classified as 2 injuries.
The most frequently reported specific device problem is “Contamination /Decontamination Problem” (2 reports).
5 other recalls cover devices cleared under the same FDA submission (K083641, K913859); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Contamination /Decontamination Problem2
- Dent in Material2
Patient problems
- Chest Pain2
- Low Oxygen Saturation2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryOct 25, 2023Dent in Material; Contamination /Decontamination Problem; Dent in Material; Contamination /Decontamination Problem
IT WAS REPORTED THAT THE TRACHEOSTOMY TUBE HAS DEVELOPED ISSUES OVER ONE MONTH. SECRETIONS ARE ADHERING TO ITS OUTER SURFACE, AN INDENTATION ON THE TUBE, AND A NON-SMOOTH SILICONE TEXTURE THAT ENCOURAGES SECRETION BUILDUP. NO INJURY REPORTED. CHEST INFECTION POSSIBLY CAUSED BY THE HARD SET SECRETIONS BEING ON THE OUTER TUBE. AFTER THREE DAYS THE REPLACEMENT TUBE WAS REVIEWED. SECRETIONS AGAIN FOUND STUCK TO THE SIDE OF THE OUTER TUBE. UNDER GUIDANCE FROM "US" THIS WAS AGAIN CHANGED. AGAIN AFTER THREE DAYS FURTHER SECRETIONS WERE FOUND ADHERED TO THE OUTSIDE OF THE TUBE. THE STOMA IS RED, PATIENT HAD CHEST PAIN, REDUCED AIR ENTRY AND STARTED TREATMENT FOR CHEST INFECTION. AUGMENTIN ANTIBIOTICS FOR INFECTION CREATED IN LUNGS. A1: ONE PATIENT, TWO PRODUCT MALFUNCTIONS. (B)(6) BOTH REPRESENT THE SAME PATIENT. THIS IS THE SECOND MALFUNCTION REPORT FOR THE RELATED COMPLAINTS.
Patient problems: Chest Pain; Low Oxygen Saturation
MAUDE report 18006329 ↗InjuryOct 25, 2023Dent in Material; Contamination /Decontamination Problem; Dent in Material; Contamination /Decontamination Problem
IT WAS REPORTED THAT THE TRACHEOSTOMY TUBE HAS DEVELOPED ISSUES OVER ONE MONTH. SECRETIONS ARE ADHERING TO ITS OUTER SURFACE, AN INDENTATION ON THE TUBE, AND A NON-SMOOTH SILICONE TEXTURE THAT ENCOURAGES SECRETION BUILDUP. NO INJURY REPORTED. CHEST INFECTION POSSIBLY CAUSED BY THE HARD SET SECRETIONS BEING ON THE OUTER TUBE. THE INITIAL TUBE WAS CHANGED, HARD SECRETIONS CLEANED AND STERILIZED, REPLACED WITH NEW TUBE. THE STOMA IS RED, PATIENT HAD CHEST PAIN, REDUCED AIR ENTRY AND STARTED TREATMENT FOR CHEST INFECTION. AUGMENTIN ANTIBIOTICS FOR INFECTION CREATED IN LUNGS. A1: ONE PATIENT, TWO PRODUCT MALFUNCTIONS. (B)(6) BOTH REPRESENT THE SAME PATIENT. THIS IS THE FIRST MALFUNCTION REPORT FOR THE RELATED COMPLAINTS.
Patient problems: Chest Pain; Low Oxygen Saturation
MAUDE report 18005961 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K083641, K913859. One submission often covers many models, so check the product and lot details in each record.
- Z-0205-2024 · Aug 22, 2023 · Open, ClassifiedSmiths Medical Portex Bivona Pediatric Tracheostomy Tube, Cuffless, Model 60P045, Sterile.
- Z-2946-2020 · Aug 28, 2020 · TerminatedBivona Mid-Range Aire-Cuf Adult Tracheostomy Tube This tube is intended to provide direct airway access for a tracheotomized patient for up to 29 days. It may be reprocessed up to
- Z-1465-2017 · Feb 9, 2017 · TerminatedBivona TTS (Tight to Shaft) Pediatric Tracheostomy Tube, Model No. 67SP035, Reorder No. 67SP035.
- Z-0339-2007 · Aug 31, 2006 · TerminatedBivona Adult Tracheostomy Tube, I.D. 8.5 mm, O.D 11.0 mm, Length 88 mm, TTS 11.8 mm, Mfrd by Smiths Medical Critical Care; Product code 670185.
- Z-0046-2007 · Aug 11, 2006 · TerminatedBivona Adult Tracheostomy Tube, Labeled I.D. 6.0 mm, O.D. 8.7 mm, A 7.0 mm, B 0 mm, C 53.0 mm, Mfrd by Smiths Medical Critical Care; REF 60A160.
Other Tube tracheostomy and tube cuff devices
- Shiley 8CN85HCovidien LP · Tube tracheostomy and tube cuff1 recall2 deaths354 reports
- Shiley 6CN75HCovidien LP · Tube tracheostomy and tube cuff1 recall3 deaths240 reports
- Shiley 7CN80RCovidien LP · Tube tracheostomy and tube cuff2 recalls148 reports
- Bivona 67PFSS35Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall166 reports
- Bivona 670180Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall140 reports
- Bivona 670170Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall10 deaths132 reports
- Shiley 6CN75RCovidien LP · Tube tracheostomy and tube cuff1 recall1 death121 reports
- Bivona 67PFSS40Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall115 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.