Bivona 60A170Recalls & reported problems
Icu Medical, Inc. · Class 2
All models of Bivona (469)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 15021312005561), received between Nov 29, 2023 and Nov 12, 2024 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Fitting Problem” (2 reports).
5 other recalls cover devices cleared under the same FDA submission (K083641, K913859); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fitting Problem2
- Inadequacy of Device Shape and/or Size2
- Device Markings/Labelling Problem1
- Missing Information1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 12, 2024Fitting Problem; Fitting Problem
IT WAS REPORTED, THAT DURING SET-UP, THE OPENING WAS TOO SMALL. SO, IT WAS NOT POSSIBLE TO CONNECT THE SPEAKING VALVE TO THE OPENING OF THE TRACHEOSTOMY CANNULA. IN OTHER WORDS, THE SPEAKING VALVE WAS LOOSE AND DIDN¿T FIT PROPERLY. THERE WAS NO PATIENT INVOLVEMENT. AND NO HUMAN HARM. THE EVENT OCCURRED, WHEN IT WAS TIME FOR THE PATIENT TO CHANGE THE CANNULA. THE PRODUCT WAS UNPACKED AND AFTER THE CHANGE, THE SPEECH VALVE WAS LOOSE AND FELL AT THE SLIGHTEST MOVEMENT. AFTER THE INCIDENT, A NEW PRODUCT WAS UNPACKED AND IT WORKED PERFECTLY. THE SPEECH VALVE SAT VERY WELL. THIS REPORT IS TO DOCUMENT THE EVENT NOTED, ON EMDR-43663, REPORT REFERENCE NUMBER (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20667491 ↗MalfunctionNov 12, 2024Fitting Problem; Fitting Problem
IT WAS REPORTED THAT DURING SET-UP THE OPENING WAS TOO SMALL, SO IT WAS NOT POSSIBLE TO CONNECT THE SPEAKING VALVE TO THE OPENING OF THE TRACHEOSTOMY CANNULA. IN OTHER WORDS, THE SPEAKING VALVE WAS LOOSE AND DIDN¿T FIT PROPERLY. THERE WAS NO PATIENT INVOLVEMENT AND NO HUMAN HARM. THE EVENT OCCURRED WHEN IT WAS TIME FOR THE PATIENT TO CHANGE THE CANNULA, THE PRODUCT WAS UNPACKED AND AFTER THE CHANGE, THE SPEECH VALVE WAS LOOSE AND FELL AT THE SLIGHTEST MOVEMENT. AFTER THE INCIDENT, A NEW PRODUCT WAS UNPACKED, AND IT WORKED PERFECTLY. THE SPEECH VALVE SAT VERY WELL. THE PATIENT WAS ABLE TO GO HOME. THE REPORTER STATED THAT EXACTLY THE SAME PROBLEM HAPPENED ON A PREVIOUS OCCASION WITH THE SAME PATIENT, THE PROBLEM WAS SOLVED IN THE SAME WAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20666216 ↗MalfunctionJun 19, 2024Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size
IT WAS REPORTED THAT THE ISO-15 CONNECTOR IS TOO SMALL. SPEAKING VALVES ARE NOT FIXED WHEN AN INNER CANNULA IS USED. THERE WAS NO PATIENT INVOLVEMENT AND NO HUMAN HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19566342 ↗MalfunctionJun 18, 2024Inadequacy of Device Shape and/or Size; Inadequacy of Device Shape and/or Size
IT WAS REPORTED THAT THE ISO-15 CONNECTOR IS TOO SMALL. SPEAKING VALVES ARE NOT FIXED WHEN AN INNER CANNULA IS USED. THERE WAS NO PATIENT INVOLVEMENT AND NO HUMAN HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19563743 ↗MalfunctionNov 29, 2023Device Markings/Labelling Problem; Missing Information; Device Markings/Labelling Problem; Missing Information
IT WAS REPORTED THAT THE INCLUDED INSTRUCTIONS FOR USE (IFU) IS INCOMPLETE. THE DANISH TRANSLATION WAS MISSING. ADDITIONALLY THE TRANSLATION OF THE PRODUCT NAME CONTAINED A TYPO ON THE LABEL. LABEL REPORTED TO HAVE READ "SILICONETRAKEOSTOMITUDE". CORRECT IS "SILICONETRAKEOSTOMITUBE". PHOTOS SHOW UNOPENED PRODUCT BOXES. NO PATIENT INVOLVEMENT OR ADVERSE EFFECTS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18234396 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K083641, K913859. One submission often covers many models, so check the product and lot details in each record.
- Z-0205-2024 · Aug 22, 2023 · Open, ClassifiedSmiths Medical Portex Bivona Pediatric Tracheostomy Tube, Cuffless, Model 60P045, Sterile.
- Z-2946-2020 · Aug 28, 2020 · TerminatedBivona Mid-Range Aire-Cuf Adult Tracheostomy Tube This tube is intended to provide direct airway access for a tracheotomized patient for up to 29 days. It may be reprocessed up to
- Z-1465-2017 · Feb 9, 2017 · TerminatedBivona TTS (Tight to Shaft) Pediatric Tracheostomy Tube, Model No. 67SP035, Reorder No. 67SP035.
- Z-0339-2007 · Aug 31, 2006 · TerminatedBivona Adult Tracheostomy Tube, I.D. 8.5 mm, O.D 11.0 mm, Length 88 mm, TTS 11.8 mm, Mfrd by Smiths Medical Critical Care; Product code 670185.
- Z-0046-2007 · Aug 11, 2006 · TerminatedBivona Adult Tracheostomy Tube, Labeled I.D. 6.0 mm, O.D. 8.7 mm, A 7.0 mm, B 0 mm, C 53.0 mm, Mfrd by Smiths Medical Critical Care; REF 60A160.
Other Tube tracheostomy and tube cuff devices
- Shiley 8CN85HCovidien LP · Tube tracheostomy and tube cuff1 recall2 deaths354 reports
- Shiley 6CN75HCovidien LP · Tube tracheostomy and tube cuff1 recall3 deaths240 reports
- Shiley 7CN80RCovidien LP · Tube tracheostomy and tube cuff2 recalls148 reports
- Bivona 67PFSS35Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall166 reports
- Bivona 670180Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall140 reports
- Bivona 670170Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall10 deaths132 reports
- Shiley 6CN75RCovidien LP · Tube tracheostomy and tube cuff1 recall1 death121 reports
- Bivona 67PFSS40Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall115 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page