Skip to content

Bivona 67HA60Recalls & reported problems

Icu Medical, Inc. · Class 2

All models of Bivona (469)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 15021312013795), received between Oct 13, 2022 and May 14, 2026 — classified as 3 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Break” (4 reports).

1 other recall cover devices cleared under the same FDA submission (K081440); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break4
  • Deflation Problem3
  • Device Markings/Labelling Problem1
  • Leak/Splash1
  • Separation Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Hypoxia3

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 14, 2026Leak/Splash

    IT WAS REPORTED THAT THE TRACH TUBE EXHIBITED A CUFF LEAKAGE DURING PATIENT USE. THE DEVICE WAS REPLACED AND THE ISSUE RESOLVED. UNKNOWN INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25179457 ↗
  • MalfunctionMar 13, 2025Break; Break

    IT WAS REPORTED THAT THE TRACH WAS DELIVERED IN A SEALED BOX, AND WHEN THE TRACH WAS OPENED AND INSERTED, IT WAS FOUND THAT THE BALLON HAD BEEN CUT OFF THE TRACH. THE TRACH WAS REMOVED, AND BACKUP WAS INSERTED. THIS HAPPENED AT THE PATIENT'S HOUSE WHILE IN USE WITH PATIENT. THERE WAS PATIENT INVOLVEMENT, AND THE EVENT AFFECTED PATIENT CARE. HOWEVER, THERE WAS NO PATIENT HARM/ADVERSE EVENT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21596170 ↗
  • MalfunctionSep 10, 2024Separation Problem; Separation Problem

    IT WAS REPORTED THAT WHEN TRACH WAS OPENED AND INSERTED, IT WAS FOUND THAT THE BALLOON HAD BEEN CUT OFF THE TRACH. TRACH WAS REMOVED AND BACKUP INSERTED. THERE WAS MEDICAL INTERVENTION REQUIRED. THERE WAS PATIENT INVOLVEMENT, AND NO PATIENT EVENT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20185209 ↗
  • InjuryFeb 9, 2023Break; Deflation Problem; Break; Deflation Problem

    IT WAS REPORTED THAT THE CUFF OF THE TRACHEOSTOMY TUBE BROKE WHILE IN USE WITH THE PATIENT. THE PATIENT EXPERIENCED RESPIRATORY DISTRESS AND WAS MANUALLY VENTILATED. THE EVENT OCCURRED AFTER 25 DAYS OF USE.

    Patient problems: Hypoxia

    MAUDE report 16342514 ↗
  • InjuryFeb 9, 2023Break; Deflation Problem; Break; Deflation Problem

    IT WAS REPORTED THAT THE CUFF OF THE TRACHEOSTOMY TUBE BROKE WHILE IN USE WITH THE PATIENT. THE PATIENT EXPERIENCED RESPIRATORY DISTRESS AND WAS MANUALLY VENTILATED. THE EVENT OCCURRED AFTER 25 DAYS OF USE.

    Patient problems: Hypoxia

    MAUDE report 16342501 ↗
  • InjuryFeb 9, 2023Break; Deflation Problem; Break; Deflation Problem

    IT WAS REPORTED THAT THE CUFF OF THE TRACHEOSTOMY TUBE BROKE WHILE IN USE WITH THE PATIENT. THE PATIENT EXPERIENCED RESPIRATORY DISTRESS AND WAS MANUALLY VENTILATED. THE EVENT OCCURRED AFTER 25 DAYS OF USE.

    Patient problems: Hypoxia

    MAUDE report 16342236 ↗
  • MalfunctionOct 13, 2022Device Markings/Labelling Problem; Device Markings/Labelling Problem

    IT WAS REPORTED THAT UPON OPENING THE PRODUCT, THE NURSE READ THE PRODUCT INSTRUCTION FOR USE (IFU) AND COMPARED THE ENGLISH TEXT TO THE FINNISH TEXT AND NOTICED THAT THE TRANSLATION WAS NOT CORRECT, OBSERVED WITH FOUR LOT NUMBERS. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15597297 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K081440. One submission often covers many models, so check the product and lot details in each record.

  • Z-2485-2020 · May 26, 2020 · Terminated
    Pediatric Adjustable Flange Tracheostomy Tube Cuffless

Other Tube tracheostomy and tube cuff devices