Tomcat® TOMCAT SYSTEMRecalls & reported problems

Hologic, Inc. · Tomcat® Instrument. · Class 1

Adverse event reports
9
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 15420045504677), received between Sep 18, 2018 and Sep 29, 2026 — classified as 7 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Contamination” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 3 reportsSep 2026: 4 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Contamination3
  • Contamination /Decontamination Problem3
  • Difficult to Open or Close1
  • Leak/Splash1
  • Mechanical Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions8
  • Disability1
  • Patient Problem/Medical Problem1

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • InjurySep 29, 2026Contamination

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50940948 ↗
  • InjurySep 29, 2026Contamination

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50940930 ↗
  • InjurySep 29, 2026Contamination

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50939581 ↗
  • InjurySep 16, 2026Contamination /Decontamination Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50788946 ↗
  • InjuryAug 25, 2026Contamination /Decontamination Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50439122 ↗
  • InjuryAug 25, 2026Contamination /Decontamination Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50438935 ↗
  • MalfunctionAug 18, 2026Leak/Splash

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50301936 ↗
  • MalfunctionApr 28, 2026Mechanical Problem

    ON (B)(6) 2026, A CUSTOMER REPORTED CONTAMINATION FROM THE TOMCAT INSTRUMENT (SN: (B)(6). THE CUSTOMER NOTICED MULTIPLE SAMPLES ALIQUOTED FROM THE TOMCAT RETURNED WITH A HIGHER PREVALENCE OF TRICHOMONAS VAGINALIS POSITIVE RESULTS. THE CUSTOMER OBSERVED THAT THE TOMCAT PIPETTE TIPS LEFT A ¿DRAGGING¿ TRAIL OF DRIED LIQUID, THE PIPETTOR MOTION/ MOVEMENT APPEARED INCONSISTENT AND THERE WERE NO INSTRUMENT ERRORS DUE TO THIS ISSUE. THE CUSTOMER AGREED TO PUT THE RESULT REPORTING ON HOLD AND NOT TO USE THE TOMCAT INSTRUMENT UNTIL SERVICE WAS PERFORMED. ON (B)(6) 2026, A HOLOGIC FIELD SERVICE ENGINEER (FSE) WENT ONSITE AND CONFIRMED CUSTOMER¿S OBSERVATION. FSE SERVICED THE INSTRUMENT. THE INSTRUMENT PASSED VERIFICATION TESTING AND WAS CONFIRMED OPERATIONAL BEFORE BEING RELEASED BACK TO THE CUSTOMER FOR USE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25021262 ↗
  • InjurySep 18, 2018Difficult to Open or Close; Difficult to Open or Close

    A CUSTOMER COMPLAINED THAT AFTER THEIR THINPREP VIALS WERE FINISHED PROCESSING BY THE TOMCAT INSTRUMENT, THE RETURNED VIALS WERE RECAPPED TOO TIGHT. THIS CAUSED THEIR CYTOLOGISTS TO EXPERIENCE PAIN IN THEIR WRISTS WHEN UNCAPPING THE VIALS. ONE CYTOTECH HAS ASKED FOR MEDICAL ATTENTION AND BEEN DIAGNOSED WITH CARPAL TUNNEL SYNDROME THAT COULD BE ATTRIBUTED WITH UNCAPPING THESE VIALS. PER RISK ASSESSMENT, THE SEVERITY OF THIS RISK IS SERIOUS WHERE TIGHTLY CAPPED THINPREP VIALS COULD HAVE RESULTED IN A CUSTOMER SEEKING MEDICAL INTERVENTION AND BEING DIAGNOSED WITH CARPAL TUNNEL SYNDROME. HOWEVER, THE PROBABILITY OF HARM IS REMOTE AS BEING DIAGNOSED WITH CARPAL TUNNEL SYNDROME WHILE JUST UNCAPPING THINPREP VIALS IS UNLIKELY BUT POSSIBLE TO OCCUR OVER THE LIFETIME OF THE PRODUCT. FURTHER INVESTIGATION INTO THIS ISSUE IS ONGOING.

    Patient problems: Disability; Patient Problem/Medical Problem

    MAUDE report 7887349 ↗

Other STATION, PIPETTING AND DILUTING, FOR CLINICAL USE devices

All STATION, PIPETTING AND DILUTING, FOR CLINICAL USE devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.