Change Healthcare Enterprise Viewer 2.1Recalls & reported problems
Change Healthcare Canada Company · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 17540262010039), received between Mar 15, 2021 and Apr 19, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Application Program Problem” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K181185); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Application Program Problem2
- Computer Software Problem2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 19, 2021Computer Software Problem; Application Program Problem; Computer Software Problem; Application Program Problem
THE CUSTOMER REPORTED THAT WHEN VIEWING STUDIES IN CHEV, THEY DID NOT RETAIN THE PRESENTATION STATE FROM THE SAME STUDY IN PACS. THERE WAS NO PATIENT HARM REPORTED AS A RESULT OF THIS ISSUE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11689299 ↗MalfunctionMar 15, 2021Computer Software Problem; Application Program Problem; Computer Software Problem; Application Program Problem
A NEUROSURGEON INITIALLY MISINTERPRETED ANCHOR IMAGES DISPLAYED IN THE VIEWPORT OF THE CHANGE HEALTHCARE ENTERPRISE VIEWER (CHEV) AS A PRIOR STUDY. IT WAS REPORTED THIS CAUSED THE NEUROSURGEON TO ALMOST USE THE WRONG IMAGE FOR SURGERY. NO ADVERSE CONSEQUENCES WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11488096 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K181185. One submission often covers many models, so check the product and lot details in each record.
- Z-1773-2021 · Apr 19, 2021 · Open, ClassifiedChange Healthcare Enterprise Viewer - Product Usage: intended to be used with off-the-shelf hardware for the 2D and 3D display of DICOM and non-DICOM medical images, reports, and m
- Z-1508-2021 · Mar 17, 2021 · Open, ClassifiedChange Healthcare Enterprise Viewer
Other System, Image Processing, Radiological devices
- Interventional Workspot Interventional Workspot - 1Philips Medical Systems Nederland B.V. · System, Image Processing, Radiological13 recalls24 reports
- Synapse Radiology PACS Synapse Radiology PACS Software LicenseFujifilm Healthcare Americas Corporation · System, image processing, radiological9 recalls38 reports
- CENTRICITY UNIVERSAL VIEWER ZFP CLIENT 6.0Ge Healthcare · System, image processing, radiological8 recalls0 reports
- CENTRICITY UNIVERSAL VIEWER 6.0Ge Healthcare · System, image processing, radiological8 recalls0 reports
- CENTRICITY UNIVERSAL VIEWER 7.0Ge Healthcare · System, image processing, radiological6 recalls0 reports
- IntelliSpace Cardiovascular 8Philips Medical Systems Nederland B.V. · System, Image Processing, Radiological2 recalls132 reports
- CA1000 2.0 SP 14Ge Healthcare · System, image processing, radiological4 recalls0 reports
- VMA 2Ortho Kinematics, Inc. · System, Image Processing, Radiological4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page