Stainless Steel Femoral Nailing System 1Recalls & reported problems
Orthofix Srl · FLEXIBLE REAMER D 12.5 MM · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 18032568033724), received between Feb 19, 2025 and Feb 19, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Mechanical Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Mechanical Problem1
Patient problems
- Oversedation1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 19, 2025Mechanical Problem; Mechanical Problem
THE INFORMATION INITIALLY PROVIDED BY LOCAL DISTRIBUTOR INDICATES: EVENT NOTIFIED BY THE HOSPITAL TO ANSM; ANSM REF: (B)(4) HOSPITAL NAME: (B)(6) DATE OF SURGERY: ON (B)(6) 2025 SURGERY DESCRIPTION: FRACTURE TREATMENT PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM EVENT DESCRIPTION: "CUSTOMER STATEMENT: WE INFORM YOU OF A SERIOUS INCIDENT WHICH OCCURRED ON FEBRUARY 7, 2025, DURING A LONG GAMMA NAIL OPERATION. DURING THE OPERATION, THE SIZE 12.5 REAMER REFERENCE (B)(4) FROM THE BOX OF MONOBLOC REAMERS N°1 COMPLETELY UNWOUND INSIDE THE PATIENT. THE REMOVAL OF THIS MATERIAL LASTED 2 HOURS WITH LOSS OF LUCK FOR THE PATIENT". THE COMPLAINT REPORT FORM ALSO INDICATES: THE DEVICE FAILURE HAD ADVERSE EFFECTS ON PATIENT THE INITIAL SURGERY WAS NOT COMPLETED WITH THE DEVICE THE EVENT LED TO A DELAY IN THE DURATION OF THE SURGICAL PROCEDURE: 2 HOURS PRODUCT IS AVAILABLE FOR RETURN. ON FEBRUARY 12, 2025, ORTHOFIX RECEIVED THE FOLLOWING ADDITIONAL DETAILS: "IT TOOK 2 HOURS TO EXTRACT THE REAMER FROM THE CENTROMEDULLARY CANAL. THIS PROLONGED THE INITIAL OPERATION. SO FAR, NO FURTHER COMPLICATIONS FOR THE PATIENT". MANUFACTURER REF: 2025
Patient problems: Oversedation
MAUDE report 21410020 ↗
Other Rod, Fixation, Intramedullary And Accessories devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page