Centronail Titanium Humeral Nailing System 1Recalls & reported problems
Orthofix Srl · TITANIUM LOCKING SCREW D.4.0 MM-L.25 MM · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 18032568868487), received between Jul 8, 2016 and Jul 8, 2016 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Fracture” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Fracture2
Patient problems
- Device Embedded In Tissue or Plaque2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 8, 2016Fracture; Fracture
THE INFORMATION PROVIDED BY THE LOCAL DISTRIBUTOR INDICATES: HOSPITAL NAME: (B)(6), SURGEON'S NAME: DR. (B)(6); DATE OF INITIAL SURGERY: (B)(6) 2016; BODY PART TO WHICH DEVICE WAS APPLIED: LEFT HUMERAL; SURGERY DESCRIPTION: FRACTURE TREATMENT; PATIENT'S INFORMATION: (B)(6) YEARS OLD, MALE, PREVIOUS HEALTH CONDITION: NORMAL. PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE; TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM; EVENT DESCRIPTION: DURING THE SURGERY, BOTH DEVICES BROKE BETWEEN THE SCREW HEAD AND BODY AT MOMENT OF DISTAL LOCKING HANDLING. THE BROKEN SCREWS ARE STILL IN THE PATIENT, BECAUSE THE PHYSICIAN EXPECTS TO EXPLANT THEM WHEN THE NAIL REMOVAL WILL BE PERFORMED. NOTE: THE HEAD OF SCREWS ARE AVAILABLE TO RETURN FOR INVESTIGATION. THE COMPLAINT REPORT FORM ALSO INDICATES: THE DEVICE FAILURE HAD ADVERSE EFFECTS ON PATIENT; THE SURGERY WAS NOT COMPLETED WITH USED DEVICE; A REPLACEMENT DEVICE WAS IMMEDIATELY AVAILABLE TO COMPLETE SURGERY; THE EVENT LED TO A CLINICALLY RELEVANT INCREASE IN THE DURATION OF THE SURGICAL PROCEDURE -TOTAL DURATION OF THE SURGICAL PROCEDURE: 5. HOURS; THE ESTIMATIVE OF EXTRA TIME NEEDED DUE TO THE SCREWS FAILURE IS 40 MIN. AN ADDITIONAL
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 5778549 ↗MalfunctionJul 8, 2016Fracture; Fracture
THE INFORMATION PROVIDED BY THE LOCAL DISTRIBUTOR INDICATES: HOSPITAL NAME: HOSPITAL (B)(6), SURGEON'S NAME: DR. (B)(6); DATE OF INITIAL SURGERY: (B)(6) 2016; BODY PART TO WHICH DEVICE WAS APPLIED: LEFT HUMERAL; SURGERY DESCRIPTION: FRACTURE TREATMENT; PATIENT'S INFORMATION: (B)(6), MALE, PREVIOUS HEALTH CONDITION: NORMAL. PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE; TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM; EVENT DESCRIPTION: DURING THE SURGERY BOTH DEVICES BROKE BETWEEN THE SCREW HEAD AND BODY AT MOMENT OF DISTAL LOCKING HANDLING. THE BROKEN SCREWS ARE STILL IN THE PATIENT, BECAUSE THE PHYSICIAN EXPECTS TO EXPLANT THEM WHEN THE NAIL REMOVAL WILL BE PERFORMED. NOTE: THE HEAD OF SCREWS ARE AVAILABLE TO RETURN FOR INVESTIGATION. THE COMPLAINT REPORT FORM ALSO INDICATES: THE DEVICE FAILURE HAD ADVERSE EFFECTS ON PATIENT; THE SURGERY WAS NOT COMPLETED WITH USED DEVICE; A REPLACEMENT DEVICE WAS IMMEDIATELY AVAILABLE TO COMPLETE SURGERY; THE EVENT LED TO A CLINICALLY RELEVANT INCREASE IN THE DURATION OF THE SURGICAL PROCEDURE - TOTAL DURATION OF THE SURGICAL PROCEDURE: 5 HOURS; THE ESTIMATIVE OF EXTRA TIME NEEDED DUE TO THE SCREWS FAILURE IS 40 MIN. AN ADDITIONAL S
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 5778537 ↗
Other Nail, Fixation, Bone devices
- NA 03.043.024Synthes GmbH · NAIL, FIXATION, BONE234 reports
- NA 03.010.440Synthes GmbH · NAIL, FIXATION, BONE70 reports
- TRIGEN 71676627Smith & Nephew, Inc. · NAIL, FIXATION, BONE1 recall2 reports
- TRIGEN 71676628Smith & Nephew, Inc. · NAIL, FIXATION, BONE1 recall0 reports
- NA 03.043.018Synthes GmbH · NAIL, FIXATION, BONE33 reports
- TRIGEN 71675383Smith & Nephew, Inc. · NAIL, FIXATION, BONE29 reports
- NA 03.010.441Synthes GmbH · NAIL, FIXATION, BONE27 reports
- NA 03.010.435Synthes GmbH · NAIL, FIXATION, BONE24 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page