Ankle Compression Nailing System 1 (REF 99-T77225)Recalls & reported problems
Orthofix Srl · TITANIUM ANKLE HINDFOOT NAIL 12/250 · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 18054242512974), received between Jul 21, 2021 and Jul 21, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Mechanical Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Mechanical Problem2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 21, 2021Mechanical Problem; Mechanical Problem
THE INFORMATION PROVIDED BY LOCAL DISTRIBUTOR INDICATES: PRODUCT CODES: 99-T77225 (QUANTITY 2) AND 177305 (QUANTITY 1) - (THIS REPORTS AND 9680825-2021-00053 AND 9680825-2021-00054) BATCH NUMBER: B1047977 (THE 2 NAILS) AND UNKNOWN. DATE OF INITIAL SURGERY: (B)(6) 2021. BODY PART TO WHICH DEVICE WAS APPLIED: RIGHT ANKLE. PATIENT INFORMATION: (B)(6), MALE. PROBLEM OBSERVED DURING: HOSPITAL PRE-USE INSPECTION. TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM. EVENT DESCRIPTION: "DURING AHN CASE, THE FIRST 2 NAILS OPENED (99-T77225) HAD A STUCK INTERNAL COMPRESSION MECHANISM AND WOULD NOT MOVE. A COMPRESSION DRIVER (177305) BROKE TRYING TO GET IT LOOSE. A 12/300 NAIL WAS OPENED INSTEAD DUE TO THE ISSUE. THIS WAS NOT ABLE TO BE INSERTED DUE TO THE CURVATURE OF THE TIBIA. EVENTUALLY, A 12/200 (99-T77220) WAS ABLE TO BE USED FOR THE PATIENT. WHEN PLACING THE PA CALCANEUS SCREW ON THE NOW 200 SIZED NAIL, IT MISSED THE NAIL COMPLETELY. " THE COMPLAINT REPORT FORM ALSO INDICATES: THE DEVICE FAILURE DID NOT HAVE ANY ADVERSE EFFECTS ON PATIENT. THE INITIAL SURGERY WAS NOT COMPLETED WITH THE DEVICE. A REPLACEMENT DEVICE OF SAME MODEL WAS IMMEDIATELY AVAILABLE TO COMPLETE SURGERY. THE EVENT LED TO A D
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12201187 ↗MalfunctionJul 21, 2021Mechanical Problem; Mechanical Problem
THE INFORMATION PROVIDED BY LOCAL DISTRIBUTOR INDICATES: - PRODUCT CODES: 99-T77225 (QUANTITY 2) AND 177305 (QUANTITY 1) - (MFR REPORTS 9680825-2021-00052 AND 9680825-2021-00053 AND 9680825-2021-00054). - BATCH NUMBER: B1047977 (THE 2 NAILS) AND UNKNOWN. - DATE OF INITIAL SURGERY: (B)(6) 2021. - BODY PART TO WHICH DEVICE WAS APPLIED: RIGHT ANKLE. - PATIENT INFORMATION: 39 YEARS, MALE. - PROBLEM OBSERVED DURING: HOSPITAL PRE-USE INSPECTION. - TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM. - EVENT DESCRIPTION: "DURING AHN CASE, THE FIRST 2 NAILS OPENED (99-T77225) HAD A STUCK INTERNAL COMPRESSION MECHANISM AND WOULD NOT MOVE. A COMPRESSION DRIVER (177305) BROKE TRYING TO GET IT LOOSE. A 12/300 NAIL WAS OPENED INSTEAD DUE TO THE ISSUE. THIS WAS NOT ABLE TO BE INSERTED DUE TO THE CURVATURE OF THE TIBIA. EVENTUALLY, A 12/200 (99-T77220) WAS ABLE TO BE USED FOR THE PATIENT. WHEN PLACING THE PA CALCANEUS SCREW ON THE NOW 200 SIZED NAIL, IT MISSED THE NAIL COMPLETELY. " THE COMPLAINT REPORT FORM ALSO INDICATES: - THE DEVICE FAILURE DID NOT HAVE ANY ADVERSE EFFECTS ON PATIENT. - THE INITIAL SURGERY WAS NOT COMPLETED WITH THE DEVICE. - A REPLACEMENT DEVICE OF SAME MODEL WAS IMMEDIATELY AVAILABL
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12201186 ↗
Other Rod, Fixation, Intramedullary And Accessories devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page