CHIMAERA Hip Fracture System 1 (REF 99-T93705)Recalls & reported problems
Orthofix Srl · CHIMAERA HFS LAG SCREW SLIDING L105MM STERILE · Class 2
All models of CHIMAERA Hip Fracture System (16)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 18054242514770), received between Jun 4, 2019 and Jun 4, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Mechanical Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Mechanical Problem1
Patient problems
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 4, 2019Mechanical Problem; Mechanical Problem
THE INFORMATION PROVIDED BY THE HOSPITAL INVOLVED AND THE SALES MANAGER INDICATES: HOSPITAL NAME: (B)(6), SURGEON NAME: DR. (B)(6), DATE OF INITIAL SURGERY: (B)(6) 2019, BODY PART TO WHICH DEVICE WAS APPLIED: FEMUR, SURGERY DESCRIPTION: FRACTURE TREATMENT, PATIENT INFORMATION: FEMALE, (B)(6), PROBLEM OBSERVED DURING: CLINICAL USE ON PATIENT/INTRAOPERATIVE, TYPE OF PROBLEM: DEVICE FUNCTIONAL PROBLEM, EVENT DESCRIPTION: "DURING THE ENGAGEMENT PHASE OF THE MAIN SLIDING SCREW IT STOPPED WITHOUT ENGAGING PROPERLY AND IT WAS NOT POSSIBLE TO REMOVE IT. THE SAME HAPPENED WITH THE SUPPLEMENTARY LAG SCREW". THE COMPLAINT REPORT FORM ALSO INDICATES: THE DEVICE FAILURE HAD ADVERSE EFFECTS ON PATIENT: LOSS OF FRACTURE REDUCTION. THE INITIAL SURGERY WAS COMPLETED WITH THE DEVICES. THE EVENT LED TO A CLINICALLY RELEVANT INCREASE IN THE DURATION OF THE SURGICAL PROCEDURE: DELAY IN SURGERY AND CUT OUT. PATIENT'S X-RAY IMAGES ARE AVAILABLE. MANUFACTURER REFERENCE NUMBER: (B)(4).
Patient problems: No Code Available
MAUDE report 8666699 ↗
Other Rod, Fixation, Intramedullary And Accessories devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.