Skip to content

Kendall 31013926 (REF 31013926-)Recalls & reported problems

Cardinal Health 200, LLC · Kendall 500 series Diaphoretic Foam Monitoring electrode - Tear drop shape ( 30/PK) · Class 2

All models of Kendall (31)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20192253017196), received between Mar 24, 2026 and Mar 24, 2026 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Hypersensitivity/Allergic reaction1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 24, 2026Adverse Event Without Identified Device or Use Problem

    THE CUSTOMER REPORTED THAT THEY HAVE DEVELOPED A SEVERE ALLERGY TO THE ADHESIVE ELECTRODES USED DURING TREATMENT. THE PATIENT HAD AN EXTENSIVE RASH THAT STARTED IN THE MIDDLE OF THEIR FACE AND DESCENDED TO THEIR KNEES. THE AREA WAS BRIGHT RED AND THEY HAD AN INTENSE BURNING SENSATION ACCOMPANIED BY SEVERE ITCHING, TREMBLING AND CHILLS. NO PRODUCT WAS APPLIED BEFORE THE ELECTRODES. ABOUT 1/2 HOUR AFTER THE PLACEMENT OF THE ELECTRODES THE SKIN REACTION APPEARED WHILE THE ELECTRODES WERE STILL ON THEIR SKIN. THE FIRST TREATMENT WAS ORAL AND IT DIDN'T HELP KEEP THE REACTION FROM PROGRESSING. INTRAVENOUS CORTICOSTEROIDS WERE GIVEN AND THE PATIENT WAS UNDER OBSERVATION ON A HEART MONITOR AND BLOOD PRESSURE, LYING ON A STRETCHER. THE PATIENT HAD TO UNDERGO A SECOND INTRAVENOUS CORTICOSTEROIDS TREATMENT WHICH WORKED.

    Patient problems: Hypersensitivity/Allergic reaction

    MAUDE report 24679862 ↗

FDA clearance and classification

The FDA regulates product code DRX (electrode, electrocardiograph) under 21 CFR 870.2360 as a Class II device. 21 CFR 870.2360 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Kendall 31013926

Has the Kendall 31013926 been recalled?

No FDA recall record in our data names this exact device identifier (DI 20192253017196), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Kendall 31013926?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 24, 2026. That report lists patient problem “Hypersensitivity/Allergic reaction” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Kendall 31013926?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Kendall 31013926 FDA approved?

Devices of this type (product code DRX) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Cardinal Health 200, LLC.

Who makes the Kendall 31013926, and is it still sold?

The FDA's device database lists Cardinal Health 200, LLC as the company responsible for it (brand Kendall, model 31013926). Its record shows it as in commercial distribution.