Skip to content

Jelco 96000SRecalls & reported problems

Icu Medical, Inc. · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 20351688074680), received between Aug 31, 2022 and Dec 3, 2025 — classified as 1 injury, 3 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Failure to Obtain Sample2
  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Insufficient Information1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 3, 2025Failure to Obtain Sample; Failure to Obtain Sample

    IT WAS REPORTED THAT MULTIPLE VACUTAINERS WERE NOT WORKING AS THEY SHOULD, LABS NOT DRAWING WHEN USING VACUTAINER. THERE WERE PATIENT INVOLVEMENT AND NO PATIENT INJURY OR ADVERSE EVENT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23705104 ↗
  • MalfunctionDec 3, 2025Failure to Obtain Sample; Failure to Obtain Sample

    IT WAS REPORTED THAT MULTIPLE VACUTAINERS WERE NOT WORKING AS THEY SHOULD, LABS NOT DRAWING WHEN USING VACUTAINER. THERE WERE PATIENT INVOLVEMENT AND NO PATIENT INJURY OR ADVERSE EVENT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23704982 ↗
  • InjurySep 8, 2025Break; Break

    IT WAS REPORTED THAT, WHILE IN USE TO COLLECT BLOOD, THE DEVICE WAS ATTACHED TO A PERIPHERALLY INSERTED CENTRAL CATHETER LINE, AND WHEN THE CONNECTING THE PIECE INTO THE LUMEN IT BROKE OF AND WAS STUCK IN THE PATIENT'S CENTRAL VENOUS CATHETER LUMEN. THERE WAS REPORTED PATIENT INJURY.

    Patient problems: Insufficient Information

    MAUDE report 22992283 ↗
  • MalfunctionAug 31, 2022Break; Fracture; Break; Fracture

    IT WAS REPORTED THAT THE MALE POTION OF THE VACUTAINER BROKE OFF IN THE HUB WHILE OBTAINING BLOOD CULTURE FROM A PERMCATH. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15327004 ↗

Other Tubes, vials, systems, serum separators, blood collection devices

All Tubes, vials, systems, serum separators, blood collection devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page