DLP® 10534Recalls & reported problems
Medtronic, Inc. · ADAPTER 10534 Y TYPE 8.5IN 1WAY VALVE 20 · Class 2
All models of DLP (151)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20613994685982), received between Apr 12, 2024 and Apr 12, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Obstruction of Flow” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Obstruction of Flow1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 12, 2024Obstruction of Flow; Obstruction of Flow
MEDTRONIC RECEIVED INFORMATION THAT PRIOR TO USE OF A DLP ¿Y¿ TYPE VENTING ADAPTER, IT WAS REPORTED THAT THE ONE WAY VALVE IN THE DEVICE WAS NOT WORKING. THE DEVICE WAS REPLACED. THERE WAS NO PATIENT INVOLVEMENT, SO NO ADVERSE EFFECT OCCURRED. MEDTRONIC RECEIVED ADDITIONAL INFORMATION THAT TYPICALLY, DURING BYPASS, THE PERFUSIONIST FLUSHES CARDIOPLEGIA SOLUTION THROUGH THE CARDIOPLEGIA DEVICE AND LINE TO THE TABLE, THEN TO THE CARDIOPLEGIA WYE (RETURNED), AND FINALLY BACK TO THE PUMP VIA THE VENT LINE. THE VENT INCLUDES A GRAVITY LOOP, SO WHEN CARDIOPLEGIA IS FLUSHED, THERE IS MINIMAL RESISTANCE UNLESS THE SURGEON HAS ACCIDENTALLY CLAMPED THE WYE SOMEWHERE. DESPITE FLUSHING THE CARDIOPLEGIA, LITTLE TO NO SOLUTION PASSED THE ONE-WAY VALVE IN THE CARDIOPLEGIA WYE. THE TEAM CHECKED THEIR CLAMPS, FINDING ONLY ONE ON THE CARDIOPLEGIA CANNULA, AS REQUIRED TO PREVENT SOLUTION OR AIR FROM REACHING THE PATIENT BEFORE APPLYING THE CROSS CLAMP. WHEN HIGH LINE PRESSURES WERE DETECTED BACK AT THE PUMP, THE CUSTOMER REPORTED THIS. NO OBVIOUS MECHANICAL FAULT WAS FOUND IN THE LINE, SO THE TEAM OPTED TO REPLACE THE WYE. THE SECOND WYE DIDN'T PRESENT ANY ISSUES, AND NO OTHER COMPONENTS WERE CHANGED
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19095362 ↗
Other Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass devices
- Indeflator 1003327Abbott Vascular Inc. · Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass2 recalls722 reports
- Copilot 1003331Abbott Vascular Inc. · Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass189 reports
- DLP® 11001GMedtronic, Inc. · Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass2 recalls0 reports
- RHV 23242Abbott Vascular Inc. · Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass66 reports
- DLP® 14000Medtronic, Inc. · Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass1 recall2 reports
- PhD™ 00884450746745Merit Medical Systems, Inc. · Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass1 recall2 reports
- PhD™ 00884450746714Merit Medical Systems, Inc. · Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass1 recall1 report
- NAMIC 64038301Medline Industries, Inc. · Adaptor, stopcock, manifold, fitting, cardiopulmonary bypass1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page