WANG MW-319Recalls & reported problems
Conmed Corporation · WANG TRANSBRONCHIAL HISTOLOGY NEEDLE FOR CENTRAL REGION, 1.9 MM X 130 CM · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20653405052729), received between Sep 18, 2018 and Sep 18, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
4 other recalls cover devices cleared under the same FDA submission (K914181); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 18, 2018Break; Break
THE CUSTOMER REPORTED AN ISSUE WITH THE MW-319, TRAN HISTOLOGY NEEDLE. IT WAS REPORTED THAT DURING A BRONCHOSCOPY ON (B)(6) 2018, AS THE PHYSICIAN WAS DIRECTING USE OF THE WANG NEEDLE FOR A TRANSBRONCHIAL BIOPSY, THE NURSE ACTUATED THE DEVICE FOR NEEDLE OUT POSITION, AND A TINY WHITE OBJECT SHOT OFF THE DEVICE AND INTO THE LUMEN OF THE BRONCHIAL TREE. IT WAS SUCCESSFULLY RETRIEVED USING FORCEPS AND REMOVED FROM THE PATIENT. A DIFFERENT WANG NEEDLE DEVICE WAS USED TO COMPLETE THIS PORTION OF THE PROCEDURE. ADDITIONAL INFORMATION WAS OBTAINED INDICATING THE ISSUE OCCURRED ABOUT 10-15 MINUTES INTO THE PROCEDURE. NO SUCTION WAS BEING APPLIED, THERE WAS NO UNDUE RESISTANCE NOTED, AND NO PROBLEM NOTED WITH THE DEVICE PRIOR TO EVENT. THE PHYSICIAN HAD ALREADY DONE ONE PASS WITH THE WANG NEEDLE AND OBTAINED SPECIMEN. IN THAT FIRST PASS, THE PHYSICIAN STATED THAT THE TISSUE AT THE CARINA WAS VERY TOUGH SO SHE NEEDED TO USE SOME FORCE TO GET THE NEEDLE/INTRODUCER (BOTH IN THE EXTENDED POSITION) INTO THE BIOPSY SITE. WHEN THEY WENT FOR THE SECOND PASS, THEY SAW THE WHITE RUBBERY BUSHING DISLODGE FROM THE SHEATH, POP OFF AND INTO THE LUNG. IT WAS CONFIRMED THAT THERE WAS NO INJURY TO THE PATIE
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7885524 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K914181. One submission often covers many models, so check the product and lot details in each record.
- Z-0502-2013 · Nov 20, 2012 · TerminatedWANG Transbronchial Aspiration Needles Cat. No. MW-222, WANG Cytology Needles, Central or Peripheral Regions, 22 g x 13 mm long needle. --- Common Name: Bronchoscope (flexible or
- Z-0504-2013 · Nov 20, 2012 · TerminatedWANG Transbronchial Aspiration Needles Cat. No. SW-121, WANG Cytology Needles, Central, Carinal and Mediastinal Regions, 21 g x 15 mm long needle. --- Common Name: Bronchoscope (f
- Z-0505-2013 · Nov 20, 2012 · TerminatedWANG Transbronchial Aspiration Needles Cat. No. MW-221, WANG Cytology Needles, Central or Peripheral Regions, 21 g x 15 mm long needle. --- Common Name: Bronchoscope (flexible or
- Z-0503-2013 · Nov 20, 2012 · TerminatedWANG Transbronchial Aspiration Needles Cat. No. MW-322, WANG Cytology Needles, Central, Mediastinal and Hilar Regions, 22 g x 13 mm long needle. --- Common Name: Bronchoscope (fle
Other BRONCHOSCOPE (FLEXIBLE OR RIGID) devices
- EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS BF-1TH190Olympus Medical Systems Corp. · BRONCHOSCOPE (FLEXIBLE OR RIGID)3 recalls5 deaths1,557 reports
- EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS BF-H190Olympus Medical Systems Corp. · BRONCHOSCOPE (FLEXIBLE OR RIGID)4 recalls1 death1,214 reports
- EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS BF-XP190Olympus Medical Systems Corp. · BRONCHOSCOPE (FLEXIBLE OR RIGID)4 recalls1,146 reports
- Ion 380748Intuitive Surgical, Inc. · Bronchoscope (flexible or rigid)1 recall97 deaths1,278 reports
- VISERA ELITE XENON LIGHT SOURCE OLYMPUS CLV-S190Olympus Medical Systems Corp. · BRONCHOSCOPE (FLEXIBLE OR RIGID)1,155 reports
- EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS BF-P190Olympus Medical Systems Corp. · BRONCHOSCOPE (FLEXIBLE OR RIGID)5 recalls3 deaths621 reports
- EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS BF-1TH190Olympus Medical Systems Corp. · Bronchoscope (Flexible Or Rigid)3 recalls333 reports
- BRONCHOVIDEOSCOPE BF-1T150Olympus Medical Systems Corp. · BRONCHOSCOPE (FLEXIBLE OR RIGID)4 recalls212 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page