RAD® 1884012Recalls & reported problems
Medtronic Xomed, Inc. · BLADE 1884012 RAD12 5PK CURVED 4MM · Class 1
All models of RAD (29)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 20681490047535), received between Jan 3, 2018 and Jan 28, 2025 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Vibration” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Vibration3
- Break1
- Dull, Blunt1
- Material Fragmentation1
- Material Separation1
Patient problems
- No Consequences Or Impact To Patient5
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 28, 2025Vibration; Vibration
IT WAS REPORTED THAT WHEN THE USER INSTALLED THE BLADE INTO THE HANDPIECE FOR TESTING, FOUND THAT THE BLADE HAD OBVIOUSLY SWAY. THE USER THEN TRIED TO RECONNECT THE BLADE BUT USELESS. FIANLLY, CHANGED A NEW BLADE TO PERFORM THE SURGERY. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21249391 ↗MalfunctionFeb 13, 2020Vibration; Dull, Blunt; Vibration; Dull, Blunt
A HEALTH CARE PROVIDER REPORTED VIA MANUFACTURER REPRESENTATIVE THAT THE BLADE WAS CONNECTED TO THE M5 AND IT WASN¿T CUTTING WHEN HE TRIED TO USE IT. WHEN THE HCP TOOK IT OUT FROM THE PATIENT, THE BLADE WAS VIBRATING VIGOROUSLY. HE TRIED TO FIX IT ON AGAIN, BUT IT WAS STILL VIBRATING VIGOROUSLY. ANOTHER PIECE OF THE BLADE WAS OPENED, BUT THE BLADE WASN¿T CUTTING AS WELL. SO, THE HCP CHANGED THE HANDPIECE TO M4, AND IT STILL WASN¿T CUTTING AS WELL. HE DECIDED TO CHANGE TO ANOTHER CONSOLE, AFTER WHICH, THE PROCEDURE PROCEEDED SMOOTHLY. THERE WAS NO PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9706002 ↗MalfunctionOct 4, 2019Vibration; Vibration
A HEALTH CARE PROVIDER (HCP) REPORTED VIA DISTRIBUTOR THAT A BLADE VIBRATED ABNORMALLY AFTER BEING USED FOR 10 MINUTES DURING A FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS). THE DOCTOR REINSTALLED THE BLADE BUT STILL COULD NOT RESOLVE THE PROBLEM. THEN, THE DOCTOR USED ANOTHER NEW BLADE TO COMPLETE THE OPERATION. THE SECOND BLADE COULD FUNCTION PROPERLY WITHOUT VIBRATION WITH THE SAME HANDPIECE. IT WAS THE INITIAL USE OF THE BLADE. NO ERROR CODE WAS DISPLAYED ON THE CONSOLE. THERE WAS A 10 MINUTE DELAY. THERE WAS NO PATIENT IMPACT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9156983 ↗MalfunctionNov 20, 2018Material Separation; Material Separation
A HEALTH CARE PROVIDER (HCP) REPORTED VIA A MANUFACTURER REPRESENTATIVE THAT A BLADE BROKE INTO TWO PIECES WITHIN THE PATIENT'S CAVITY DURING THE PROCEDURE. THE HCP NOTED THAT THE BLADE WAS BEING USED NORMALLY WITH A HANDPIECE. THERE WAS A DELAY IN THE PROCEDURE BECAUSE THE FRAGMENT NEEDED TO BE TAKEN OUT OF THE PATIENT'S CAVITY AND CHECK IF THERE WAS ANY INJURY. THE PROCEDURE WAS COMPLETED USING A BACK-UP DEVICE. THERE WAS NO PATIENT IMPACT OR INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8089002 ↗MalfunctionAug 30, 2018Break; Break
THE CUSTOMER REPORTED THAT THE TIP WAS DAMAGED SHORTLY AFTER HE BEGAN USING IT. THERE WAS NO IMPACT TO THE PATIENT, AND A NEW BLADE WAS OPENED TO CONTINUE THE FESS PROCEDURE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7836115 ↗MalfunctionJan 3, 2018Material Fragmentation; Material Fragmentation
DURING VISUAL INSPECTION, SMALL FRAGMENTS WERE NOTED INSIDE THE OUTER TUBE MOUTH OF THE BLADE. THE SMALL FRAGMENTS WERE STUCK TO THE TIP WALL. THE FRAGMENTS APPEAR TO BE PORTIONS OF THE INNER CUTTER TIP. THERE WAS NO PATIENT IMPACT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7162140 ↗
Other BUR, EAR, NOSE AND THROAT devices
- Quadcut® 1884380HRMedtronic Xomed, Inc. · BUR, EAR, NOSE AND THROAT1 recall7 reports
- Silver Bullet® 1882905HREMedtronic Xomed, Inc. · BUR, EAR, NOSE AND THROAT1 recall3 reports
- Diego Elite MBUR6060FRCVGyrus ACMI, LLC · BUR, EAR, NOSE AND THROAT1 recall2 reports
- Quadcut® 1884380HREMedtronic Xomed, Inc. · BUR, EAR, NOSE AND THROAT1 recall1 report
- RAD® 1882916Medtronic Xomed, Inc. · BUR, EAR, NOSE AND THROAT1 recall1 report
- N/A 1884032Medtronic Xomed, Inc. · BUR, EAR, NOSE AND THROAT1 recall0 reports
- DIEGO ELITE MBUR5060FRCVGyrus ACMI, LLC · BUR, EAR, NOSE AND THROAT1 recall0 reports
- Tricut® 1884033HREMedtronic Xomed, Inc. · BUR, EAR, NOSE AND THROAT1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page