Skip to content

ARROW IPN033430Recalls & reported problems

Teleflex Incorporated · ARROW(R) PICC Set · Class 2 · Implant

All models of ARROW (1494)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 20801902095521), received between Jun 25, 2024 and Apr 23, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

6 other recalls cover devices cleared under the same FDA submission (K113277); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Complete Blockage1
  • Difficult to Advance1
  • Stretched1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 23, 2025Break; Break

    IT WAS REPORTED "GLIDE THRU SHEATH BROKEN HALFWAY WHILE REMOVING". THERE WAS NO PATIENT HARM OR INJURY. NO MEDICAL INTERVENTION REQUIRED. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "FINE".

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21889348 ↗
  • MalfunctionJul 5, 2024Complete Blockage; Difficult to Advance; Complete Blockage; Difficult to Advance

    IT WAS REPORTED THAT: "NEW PICC WAS CHANGED TO THE PATIENT, BUT MY DOCTOR FOUND SOME DIFFICULTY DURING INSERTION. THE DISTAL PORT COULDN'T FLUSH OR WITHDRAW AFTER INSERTION AND LOCATED AT 1/3 OF SVC. THEY HAVE TRIED FEW TIMES TO RELOCATE AND FLUSH OR WITHDRAW BUT STILL FAIL. AT THE END DOCTOR REMOVED IT AND CUT THE TIP OF PICC THEN EVERYTHING GOES SMOOTHLY WITHOUT COMPLAINT." ASSOCIATED COMPLAINT 9680794-2024-00589.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19678100 ↗
  • MalfunctionJun 25, 2024Stretched; Stretched

    IT WAS REPORTED "PICC CATHETER WAS FOUND EXPANDED DURING NURSE'S ROUND". A NEW PICC LINE WAS USED AND THERAPY WAS CONTINUED. THERE WAS NO PATIENT HARM OR INJURY. THE PATIENT'S CURRENT CONDITION IS REPORTD AS "FINE".

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19605826 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K113277. One submission often covers many models, so check the product and lot details in each record.

  • Z-2378-2026 · Apr 21, 2026 · Open, Classified
    Description/REF: PI PICC: 3: 6FR x 55CM w CHG/ DLX-35563-HPKC; AGBA PICC: 2L 5.5 FR X 45 CM/ASK-44552-ABKB; AGBA PICC/DELTA KIT: 5.5 FR X 55 CM/ASK-45552-MHBV; AGBA PICC: 1L 4.5FR
  • Z-1254-2020 · Dec 20, 2019 · Terminated
    PICC Set- PR-35052-HPHNM
  • Z-2023-2018 · Apr 11, 2018 · Terminated
    ARROW PICC Set; Product codes: PR-34052-HPHNM, PR-34063-HPHNM, PR-35041-HPHNM, PR-35052-HPHNM, PR-35541-HPHNL, PR-35541-HPHNM, PR-35552-HPHNL, PR-35552-HPHNM
  • Z-0602-2018 · Jul 25, 2017 · Terminated
    ArrowADVANTAGE 5 Pressure Injectable Peripherally Inserted Central Catheter (PICC). Product Codes: PR-35041-HPHNM and CDA-35041-HPK1A.
  • Z-0182-2018 · Jun 1, 2017 · Terminated
    ArrowADVANTAGE5" Pressure Injectable Peripherally Inserted Central Catheter (PICC) The Pressure Injectable PICC is indicated for short or long term peripheral access to the central
  • Z-0207-2016 · Oct 16, 2015 · Terminated
    ARROW PICC Kit featuring Chlorag+ard Technology Midline Catheterization Kit ARROW Advantage5 Pressure Injectable PICC Kit Arrow Pressure Injectable Arrow PICC powered by Arrow VPS

Other Catheter, intravascular, therapeutic, long-term greater than 30 days devices

All Catheter, intravascular, therapeutic, long-term greater than 30 days devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page