Skip to content

Disposable Reflective Marker Sphere (DRMS) 41773Recalls & reported problems

Northern Digital Inc · Disposable Reflective Marker Spheres (DRMS) attached to reference frames and surgical instruments for use during surgical navigation in image guided surgery. One retail carton is made up of 3 Spheres per tray, 30 trays, 90 spheres total. · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 20805832010012), received between May 29, 2015 and May 29, 2015 — classified as 1 malfunction.

The most frequently reported specific device problem is “Defective Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Defective Device1
  • Material Integrity Problem1
  • Material Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 29, 2015Material Separation; Defective Device; Material Integrity Problem

    THIS EVENT WAS COMMUNICATED BY A CUSTOMER WHO RECEIVED A COMPLAINT FROM (B)(6). THE DESCRIPTION AS PROVIDED BY THE INITIAL COMPLAINANT TO OUR CUSTOMER IS AS FOLLOWS: "THE DEFECTIVE SPHERES SEEM TO HAVE HALF OF THE REFLECTIVE COATING LAYER SOMEWHAT UNWRAPPED FROM THE SPHERE UPON OPENING. THAT IS, THERE IS AN OPEN SEAM BETWEEN THE TWO HEMISPHERES OF REFLECTIVE WRAPPING" FURTHER FOLLOW-UP WITH THE INITIAL COMPLAINANT INDICATES THAT WHEN THE SPHERES WERE SCREWED ON TO THE ARRAY, THEY SPLIT DOWN THE MIDDLE, EVEN WITHOUT MUCH FORCE AND THE TWO HEMISPHERES SEPARATED. INITIAL COMPLAINANT STATED THIS HAPPENED PRIOR TO AND DURING SURGERY. INITIAL COMPLAINANT CONFIRMED NO PATIENT INJURY OR OTHER SERIOUS HARM OCCURRED AND NO SERIOUS DETERIORATION TO PATIENT HEALTH. PROCEDURE WAS COMPLETED WITH A NEW PACKAGE OF SPHERES.

    Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient

    MAUDE report 4805714 ↗

FDA clearance and classification

The FDA regulates product code OLO (orthopedic stereotaxic instrument) under 21 CFR 882.4560 as a Class II device. 21 CFR 882.4560 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Disposable Reflective Marker Sphere (DRMS) 41773

Has the Disposable Reflective Marker Sphere (DRMS) 41773 been recalled?

No FDA recall record in our data names this exact device identifier (DI 20805832010012), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Disposable Reflective Marker Sphere (DRMS) 41773?

The FDA's MAUDE database lists 1 adverse event report for this device, received on May 29, 2015. That report lists device problems “Defective Device” (1), “Material Integrity Problem” (1) and “Material Separation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Disposable Reflective Marker Sphere (DRMS) 41773?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the Disposable Reflective Marker Sphere (DRMS) 41773, and is it still sold?

The FDA's device database lists Northern Digital Inc as the company responsible for it (brand Disposable Reflective Marker Sphere (DRMS), model 41773). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Orthopedic Stereotaxic Instrument devices

All Orthopedic Stereotaxic Instrument devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page