Vacuette 456287PRecalls & reported problems
Greiner Bio-One GmbH · VACUETTE® TUBE 3.5 ml LH Lithium Heparin Separator 13x100 green cap-yellow ring, non-ridged, USA · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 29120049204674), received between Mar 8, 2024 and Mar 8, 2024 — classified as 1 malfunction.
4 other recalls cover devices cleared under the same FDA submission (K960857); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 8, 2024
GEL BARRIER TUBES ARRIVING TO THE LAB WITH LARGE AMOUNTS OF GEL STUCK TO THE SIDES OF THE TUBES/FLOATING IN THE PLASMA RESULTING IN PERSISTENT INTERRUPTIONS TO SPECIMEN TESTING DUE TO GEL CLOGGING SAMPLING PROBES ON THE CHEMISTRY ANALYZERS. WHILE MULTIPLE LOT NUMBERS OF TUBES HAVE HAD THIS ISSUE THE CURRENT PRIMARY LOT WE ARE SEEING EXCESSIVE GEL IS LOT # B2303374. WE RECEIVED THIS LOT NUMBER FROM AT LEAST 17 PHLEBOTOMY SITES WITH GEL ISSUES OCCURRING AT EACH.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18865232 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K960857. One submission often covers many models, so check the product and lot details in each record.
- Z-0502-2022 · Dec 9, 2021 · Terminatedgreiner bio-one VACUETTE TUBE, 5 ml LH Lithium Heparin Sep, 13x100 green cap-yellow ring, non-ridged, 24 racks of 50 pcs., 1200 pcs. in total, REF 456087P
- Z-1081-2012 · Dec 14, 2011 · TerminatedLH Lithium Heparin tubes, Greiner bio-one, North America, 4238 Capital Drive, Monroe, NC 28110. Venous blood collection tubes.
- Z-0623-2011 · Aug 25, 2010 · TerminatedVacuette 2 ml Lithium Heparin, Collection Tube, Manufactured by: Greiner-Bio One North America, Inc., 4238 Capital Drive, Monroe, NC. Venous blood collection tubes.
- Z-0215-2009 · Jul 29, 2008 · TerminatedVACUETTE, 2 ml Lithium Heparin Venous Blood Collection Tubes. Reference #454237, 13x75 green cap-white ring, 24 racks of 50 pcs (1200 pcs in total, non ridged, Sterile). Manufact
Other Tubes, vials, systems, serum separators, blood collection devices
- BD Vacutainer® SST™ 367986Becton, Dickinson And Company · Tubes, vials, systems, serum separators, blood collection2 recalls2,711 reports
- BD Vacutainer® Buffered Sodium Citrate (9NC) Blood Collection Tubes 363083Becton, Dickinson And Company · Tubes, vials, systems, serum separators, blood collection1 recall1,744 reports
- BD Vacutainer® SST™ II Advance 367955Becton, Dickinson U.K. Limited · Tubes, vials, systems, serum separators, blood collection1,478 reports
- BD Vacutainer® Eclipse™ Blood Collection Needle 368607Becton, Dickinson And Company · Tubes, vials, systems, serum separators, blood collection1,220 reports
- BD Vacutainer® SST™ 367983Becton, Dickinson And Company · Tubes, vials, systems, serum separators, blood collection2 recalls1,075 reports
- BD Vacutainer® K2 EDTA (K2E) 5.4mg Blood Collection Tubes 367856Becton, Dickinson And Company · Tubes, vials, systems, serum separators, blood collection1,010 reports
- BD Vacutainer® PST™ Gel and Lithium HeparinN 56 Units 367960Becton, Dickinson And Company · Tubes, vials, systems, serum separators, blood collection1 recall747 reports
- BD Vacutainer® SST™ II Advance 367957Becton, Dickinson U.K. Limited · Tubes, vials, systems, serum separators, blood collection767 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page