BD Phoenix™ PMIC-106 448416Recalls & reported problems

Becton, Dickinson And Company · BD Phoenix™ PMIC-106 · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
12
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 30382904484164), received between Nov 16, 2021 and Jun 12, 2026 — classified as 12 malfunctions.

The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (12 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 4 reportsMay 2024: 2 reportsJun 2024: 1 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 2 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Incorrect, Inadequate or Imprecise Result or Readings12

Patient problems

  • No Clinical Signs, Symptoms or Conditions12

Recent adverse event reports

The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 12, 2026Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED WHILE USING THE BD PHOENIX¿ PMIC-106 A PATIENT ISOLATE (METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS) WAS IDENTIFIED AS A METHICILLIN-SENSITIVE STAPHYLOCOCCUS AUREUS. THE USER VERIFIED THE FINAL RESULT USING CEPHEID XPERT. NO HEALTH IMPACT OR CONSEQUENCE REPORTED. THIS IS REPORT 5 OF 6.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25488315 ↗
  • MalfunctionAug 29, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED WHILE USING THE BD PHOENIX¿ PMIC-106 A PATIENT BLOOD CULTURE ISOLATE METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS (MRSA) WAS MISIDENTIFIED AS METHICILLIN-SUSCEPTIBLE STAPHYLOCOCCUS AUREUS (MSSA). THE USER NOTED THE ISOLATE'S FINAL RESULT WAS VERIFIED USING PCR AND DISC DIFFUSION AND REPEAT TESTING. NO HEALTH IMPACT OR CONSEQUENCE REPORTED. REPORT 1 OF 2.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22925924 ↗
  • MalfunctionAug 29, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED WHILE USING THE BD PHOENIX¿ PMIC-106 A PATIENT BLOOD CULTURE ISOLATE METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS (MRSA) WAS MISIDENTIFIED AS METHICILLIN-SUSCEPTIBLE STAPHYLOCOCCUS AUREUS (MSSA). THE USER NOTED THE ISOLATE'S FINAL RESULT WAS VERIFIED USING PCR AND DISC DIFFUSION AND REPEAT TESTING. NO HEALTH IMPACT OR CONSEQUENCE REPORTED. REPORT 2 OF 2.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22925913 ↗
  • MalfunctionJul 14, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED WHILE USING THE BD PHOENIX¿ PMIC-106 AN UNSPECIFIED NUMBER OF PATIENT SAMPLES RESULTED IN NO MIC FOR THE DRUG TRIMETHOPRIM / SULFAMETHOXAZOLE (SXT). NO HEALTH IMPACT OR CONSEQUENCE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19737566 ↗
  • MalfunctionJun 7, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED WHILE USING THE BD PHOENIX¿ PMIC-106 NO MIC WAS GIVEN FOR THE DRUG LEVOFLOXACIN FOR A PATIENT ENTEROCOCCUS FAECIUM ISOLATE (424161535982). NO HEALTH IMPACT OR CONSEQUENCE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19481600 ↗
  • MalfunctionMay 24, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED WHILE USING THE BD PHOENIX¿ PMIC-106 NO MIC WAS GIVEN FOR THE DRUG TRIMETHOPRIM / SULFAMETHOXAZOLE (SXT) FOR A PATIENT S. AUREUS ISOLATE (424161535968). NO HEALTH IMPACT OR CONSEQUENCE REPORTED. REPORT 2 OF 2.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19393291 ↗
  • MalfunctionMay 24, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED WHILE USING THE BD PHOENIX¿ PMIC-106 NO MIC WAS GIVEN FOR THE DRUG TRIMETHOPRIM / SULFAMETHOXAZOLE (SXT) FOR A PATIENT S. AUREUS ISOLATE (424161535977). NO HEALTH IMPACT OR CONSEQUENCE REPORTED. REPORT 1 OF 2.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19393284 ↗
  • MalfunctionApr 29, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    REPORT 1 OF 3: IT WAS REPORTED THAT WHILE TESTING WITH BD PHOENIX¿ PMIC-106, NO MIC RESULTS WERE OBTAINED FOR ANTIBIOTIC TRIMETHOPRIM-SULFAMETHOXAZOLE ON A PATIENT SAMPLE. THERE WERE NO HEALTH IMPACT OR CONSEQUENCES REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19201750 ↗
  • MalfunctionApr 29, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    REPORT 3 OF 3: IT WAS REPORTED THAT WHILE TESTING WITH BD PHOENIX¿ PMIC-106, NO MIC RESULTS WERE OBTAINED FOR ANTIBIOTIC TRIMETHOPRIM-SULFAMETHOXAZOLE ON A PATIENT SAMPLE. THERE WERE NO HEALTH IMPACT OR CONSEQUENCES REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19201744 ↗
  • MalfunctionApr 29, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    REPORT 2 OF 3: IT WAS REPORTED THAT WHILE TESTING WITH BD PHOENIX¿ PMIC-106, NO MIC RESULTS WERE OBTAINED FOR ANTIBIOTIC TRIMETHOPRIM-SULFAMETHOXAZOLE ON A PATIENT SAMPLE. THERE WERE NO HEALTH IMPACT OR CONSEQUENCES REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19201741 ↗
  • MalfunctionApr 3, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED WHILE TESTING WITH BD PHOENIX¿ PMIC-106. NO MIC RESULT WAS OBTAINED FOR TRIMETHOPRIM-SULFAMETHOXAZOLE. THERE WAS NO HEALTH IMPACT OR CONSEQUENCES REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19037899 ↗
  • MalfunctionNov 16, 2021Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT THE BD PHOENIX¿ PMIC-106 MISIDENTIFIED 2 RESULTS, WITH THE TOP ANALYZER READING THEM DIFFERENTLY THAN THE BOTTOM ONE. THERE WAS NO INDICATION OF CONFIRMATORY TESTING, AND RESULTS WERE NOT REPORTED TO CLINICIANS. THERE WAS NO REPORT OF PATIENT IMPACT. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: "THE CUSTOMER IS REPORTING 2 SUBSEQUENCE ERRONEOUS RESULTS FROM AN E18 OBSERVED AND REPORTED" "THEY RAN 2 PATIENT PANELS IN DUPLICATE THE TOP ANALYZER READ DIFFERENTLY THAN THE BOTTOM" "NO PATIENT CARE PROVIDED BASED ON ERRONEOUS RESULTS."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12822031 ↗

Other SYSTEM, TEST, AUTOMATED, ANTIMICROBIAL SUSCEPTIBILITY, SHORT INCUBATION devices

All SYSTEM, TEST, AUTOMATED, ANTIMICROBIAL SUSCEPTIBILITY, SHORT INCUBATION devices →