Skip to content

Medline FCE1232ABNRecalls & reported problems

Medline Industries, Inc. · BAR,ASSIST,FLIP DOWN FOR FCE1232 BED · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 40884389106427), received between Aug 26, 2020 and Sep 28, 2026 — classified as 2 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Loose or Intermittent Connection” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 5 reportsOct 2026: 0 reports2024202520265
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loose or Intermittent Connection4
  • Adverse Event Without Identified Device or Use Problem2
  • Fracture1
  • Insufficient Device Problem Information1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • Laceration(s)2
  • Skin Tears1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 28, 2026Loose or Intermittent Connection

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50923845 ↗
  • MalfunctionSep 18, 2026Loose or Intermittent Connection

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50829613 ↗
  • MalfunctionSep 18, 2026Loose or Intermittent Connection

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50821011 ↗
  • MalfunctionSep 16, 2026Fracture

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50794026 ↗
  • MalfunctionSep 11, 2026Loose or Intermittent Connection

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50732591 ↗
  • InjuryAug 29, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    ACCORDING TO THE CUSTOMER, ON (B)(6) 2025, A RIGHT LOWER LEG "DEGLOVING INJURY" WAS SUSTAINED BY A USER OF THE DEVICE WHILE TRANSFERRING FROM A "WHEELCHAIR TO BED." THE USER HAS BEEN HOSPITALIZED IN ACUTE CARE FOR THE "PAST TWO WEEKS" FOLLOWING SURGERY AND WOUND VAC PLACEMENT.

    Patient problems: Skin Tears

    MAUDE report 22921043 ↗
  • MalfunctionNov 30, 2020Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED A PATIENT WAS INJURED WHILE WORKING WITH TWO THERAPISTS ON TRANSFERS INTO BED. PATIENT SUSTAINED AN INJURY TO HER LOWER RIGHT LEG THAT REQUIRED MEDICAL ATTENTION.

    Patient problems: Laceration(s)

    MAUDE report 10920025 ↗
  • InjuryAug 26, 2020Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A BACKWARD FALL AND HIT HER HEAD ON THE ASSIST BAR.

    Patient problems: Laceration(s)

    MAUDE report 10456106 ↗

Other BED, AC-POWERED ADJUSTABLE HOSPITAL devices

All BED, AC-POWERED ADJUSTABLE HOSPITAL devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page