Skip to content

Shiley 18865Recalls & reported problems

Covidien LP · TaperGuard Evac Oral Tracheal Tube,Murphy Eye · Class 2

Quick summary

This Shiley TaperGuard Evac oral tracheal tube is a breathing tube used to intubate patients. Reports mostly describe air leaking from the tube's cuff so the seal and ventilator pressure could not be kept, and the connector coming apart during ventilation. There are 37 reports, with 11 injuries and no deaths, and 26 malfunctions. No recalls name this device. Reports in the last 12 months (15) were higher than the 5 in the prior 12 months.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
37
Deaths reported
0
Injuries reported
11
Recalls naming it
0

Summary

The FDA's MAUDE database contains 37 adverse event reports that list this exact device (DI 40884521032515), received between Aug 14, 2017 and Jul 7, 2026 — classified as 11 injuries, 26 malfunctions.

The most frequently reported specific device problem is “Gas/Air Leak” (16 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 2 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 2 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 10 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports20242025202610
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Gas/Air Leak16
  • Disconnection11
  • Use of Device Problem9
  • Material Separation2
  • Material Split, Cut or Torn2
  • Air Leak1
  • Failure to Seal1
  • Inflation Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions9
  • Cardiac Arrest8
  • Insufficient Information6
  • No Information5
  • Unintended Extubation4
  • No Patient Involvement3
  • Extubate2
  • No Consequences Or Impact To Patient2

Recent adverse event reports

The 25 most recent of 37 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 7, 2026Gas/Air Leak

    IT WAS REPORTED THAT DURING INTUBATION PROCEDURE, THE ENDOTRACHEAL TUBE'S CUFF HAD POOR INFLATION AND AIR LEAKAGE WAS FOUND. THE TUBE WAS REPLACED.

    Patient problems: Unintended Extubation

    MAUDE report 25732478 ↗
  • MalfunctionMay 15, 2026Use of Device Problem

    IT WAS REPORTED THAT DURING PRE-USAGE INSPECTION, THE ENDOTRACHEAL TUBE'S CUFF HAD AN AIR LEAK. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25185613 ↗
  • MalfunctionApr 11, 2026Gas/Air Leak; Failure to Seal

    IT WAS REPORTED THAT THE PILOT BALLOON OF THE ENDOTRACHEAL TUBE HAD LEAKS DURING USE. THERE WAS PROBLEMS MAINTAINING CUFF PRESSURE, REQUIRING REPEATED RE-INFLATION, SOMETIMES EVERY 10 MINUTES, TO ENSURE A PROPER SEAL. IT WAS UNKNOWN IF THERE WAS PATIENT INVOLVEMENT AT THE TIME OF THE EVENT.

    Patient problems: Insufficient Information

    MAUDE report 24847456 ↗
  • MalfunctionMar 18, 2026Use of Device Problem

    IT WAS REPORTED THAT THE CUFF OF THE ENDOTRACHEAL TUBE HAD AN AIR LEAK. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24634155 ↗
  • InjuryFeb 20, 2026Gas/Air Leak

    IT WAS REPORTED THAT THE PILOT BALLOON OF THE ENDOTRACHEAL TUBE HAD SEVERAL LEAKS. THERE WAS PROBLEMS MAINTAINING CUFF PRESSURE, REQUIRING REPEATED RE-INFLATION, SOMETIMES EVERY 10 MINUTES, TO ENSURE A PROPER SEAL. THE PATIENT HAD RESPIRATORY ARREST, WITH SUSPECTED MUCUS PLUGGING AND BRONCHOASPIRATION. IN ADDITION, BALLOON MALFUNCTIONS MAKE IT DIFFICULT TO MAINTAIN ADEQUATE VENTILATORY PRESSURE AND POSE RISKS DUE TO REPEATED MANIPULATION OF THE TUBE.

    Patient problems: Aspiration/Inhalation; Hypoventilation; Respiratory Arrest; Respiratory Failure; Unintended Extubation

    MAUDE report 24399630 ↗
  • InjuryJan 6, 2026Disconnection

    IT WAS REPORTED THAT WHEN THE FIRST RESPONDERS ARRIVED ON THE SCENE, THE PATIENT WAS ALREADY IN CARDIAC ARREST, RESUSCITATION WAS INITIATED, AND THE PATIENT WAS INTUBATED AS A PART OF THE RESUSCITATIVE EFFORTS. THE ENDOTRACHEAL TUBE'S 15MM DISCONNECTED WHILE BEING ACTIVELY VENTILATED WITH AN AMBU BAG DUE TO SLIGHT REPOSITIONING OF THE AMBU DEVICE WHILE ATTACHED TO THE TUBE. THE FIRST RESPONDER RESOLVED THE ISSUE BY RECONNECTING THE SAME 15MM CONNECTOR BACK ONTO THE TUBE AND RESUMED VENTILATION. THE PATIENT HAD NO RETURN OF SPONTANEOUS CIRCULATION, BUT THE DEATH WAS NOT A RESULT OF A DEVICE MALFUNCTION.

    Patient problems: Cardiac Arrest

    MAUDE report 23981087 ↗
  • InjuryJan 6, 2026Disconnection

    IT WAS REPORTED THAT WHEN THE FIRST RESPONDERS ARRIVED ON THE SCENE, THE PATIENT WAS ALREADY IN CARDIAC ARREST, RESUSCITATION WAS INITIATED, AND THE PATIENT WAS INTUBATED AS A PART OF THE RESUSCITATIVE EFFORTS. THE ENDOTRACHEAL TUBE'S 15MM DISCONNECTED WHILE BEING ACTIVELY VENTILATED WITH AN AMBU BAG DUE TO SLIGHT REPOSITIONING OF THE AMBU DEVICE WHILE ATTACHED TO THE TUBE. THE FIRST RESPONDER RESOLVED THE ISSUE BY RECONNECTING THE SAME 15MM CONNECTOR BACK ONTO THE TUBE AND RESUMED VENTILATION. THE PATIENT HAD NO RETURN OF SPONTANEOUS CIRCULATION, BUT THE DEATH WAS NOT A RESULT OF A DEVICE MALFUNCTION.

    Patient problems: Cardiac Arrest

    MAUDE report 23981065 ↗
  • InjuryJan 6, 2026Disconnection

    IT WAS REPORTED THAT WHEN THE FIRST RESPONDERS ARRIVED ON THE SCENE, THE PATIENT WAS ALREADY IN CARDIAC ARREST, RESUSCITATION WAS INITIATED, AND THE PATIENT WAS INTUBATED AS A PART OF THE RESUSCITATIVE EFFORTS. THE ENDOTRACHEAL TUBE'S 15MM CONNECTOR DISCONNECTED WHILE THE PATIENT WAS BEING ACTIVELY VENTILATED WITH AN AMBU BAG AFTER THE AMBULANCE HIT A BUMP WHILE TRAVELING DOWN THE ROAD. THE FIRST RESPONDER RESOLVED THE ISSUE BY RECONNECTING THE SAME 15MM CONNECTOR BACK ONTO THE TUBE AND RESUMED VENTILATION. THE PATIENT HAD NO RETURN OF SPONTANEOUS CIRCULATION, BUT THE DEATH WAS NOT A RESULT OF A DEVICE MALFUNCTION.

    Patient problems: Cardiac Arrest

    MAUDE report 23971283 ↗
  • InjuryJan 6, 2026Disconnection

    IT WAS REPORTED THAT WHEN THE FIRST RESPONDERS ARRIVED ON THE SCENE, THE PATIENT WAS ALREADY IN CARDIAC ARREST, RESUSCITATION WAS INITIATED, AND THE PATIENT WAS INTUBATED AS A PART OF THE RESUSCITATIVE EFFORTS. THE ENDOTRACHEAL TUBE'S 15MM CONNECTOR DISCONNECTED WHILE THE PATIENT WAS BEING ACTIVELY VENTILATED WITH AN AMBU BAG AFTER THE AMBULANCE HIT A BUMP WHILE TRAVELING DOWN THE ROAD. THE FIRST RESPONDER RESOLVED THE ISSUE BY RECONNECTING THE SAME 15MM CONNECTOR BACK ONTO THE TUBE AND RESUMED VENTILATION. THE PATIENT HAD NO RETURN OF SPONTANEOUS CIRCULATION, BUT THE DEATH WAS NOT A RESULT OF A DEVICE MALFUNCTION.

    Patient problems: Cardiac Arrest

    MAUDE report 23971270 ↗
  • InjuryJan 5, 2026Disconnection

    IT WAS REPORTED THAT WHEN THE FIRST RESPONDERS ARRIVED ON THE SCENE, THE PATIENT WAS ALREADY IN CARDIAC ARREST, RESUSCITATION WAS INITIATED, AND THE PATIENT WAS INTUBATED AS A PART OF THE RESUSCITATIVE EFFORTS. THE ENDOTRACHEAL TUBE'S 15MM DISCONNECTED RIGHT AFTER THE INTUBATION PROCEDURE WAS PERFORMED AS THE STYLET WAS BEING REMOVED FROM THE TUBE. THE FIRST RESPONDER RESOLVED THE ISSUE BY RECONNECTING THE SAME 15MM CONNECTOR BACK ONTO THE TUBE AND RESUMED VENTILATION. THE PATIENT HAD NO RETURN OF SPONTANEOUS CIRCULATION, BUT THE DEATH WAS NOT A RESULT OF A DEVICE MALFUNCTION.

    Patient problems: Cardiac Arrest

    MAUDE report 23970488 ↗
  • InjuryJan 5, 2026Disconnection

    IT WAS REPORTED THAT WHEN THE FIRST RESPONDERS ARRIVED ON THE SCENE, THE PATIENT WAS ALREADY IN CARDIAC ARREST, RESUSCITATION WAS INITIATED, AND THE PATIENT WAS INTUBATED AS A PART OF THE RESUSCITATIVE EFFORTS. THE ENDOTRACHEAL TUBE'S 15MM DISCONNECTED RIGHT AFTER THE INTUBATION PROCEDURE WAS PERFORMED AS THE STYLET WAS BEING REMOVED FROM THE TUBE. THE FIRST RESPONDER RESOLVED THE ISSUE BY RECONNECTING THE SAME 15MM CONNECTOR BACK ONTO THE TUBE AND RESUMED VENTILATION. THE PATIENT HAD NO RETURN OF SPONTANEOUS CIRCULATION, BUT THE DEATH WAS NOT A RESULT OF A DEVICE MALFUNCTION.

    Patient problems: Cardiac Arrest

    MAUDE report 23970482 ↗
  • MalfunctionJan 5, 2026Disconnection

    IT WAS REPORTED THAT THE ENDOTRACHEAL TUBES TOP ADAPTER CAN EASILY BE REMOVE FROM THE TUBE ITSELF WITH MINIMAL EFFORT WHILE STILL IN THE PACKAGE. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23969377 ↗
  • MalfunctionJan 5, 2026Disconnection

    IT WAS REPORTED THAT THE ENDOTRACHEAL TUBES TOP ADAPTER CAN EASILY BE REMOVE FROM THE TUBE ITSELF WITH MINIMAL EFFORT WHILE STILL IN THE PACKAGE. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23969351 ↗
  • InjuryJan 5, 2026Disconnection

    IT WAS REPORTED THAT WHEN THE FIRST RESPONDERS ARRIVED ON THE SCENE, THE PATIENT WAS ALREADY IN CARDIAC ARREST, RESUSCITATION WAS INITIATED, AND THE PATIENT WAS INTUBATED AS A PART OF THE RESUSCITATIVE EFFORTS. THE ENDOTRACHEAL TUBE'S 15MM DISCONNECTED RIGHT AFTER THE INTUBATION PROCEDURE WAS PERFORMED AS THE STYLET WAS BEING REMOVED FROM THE TUBE. THE FIRST RESPONDER RESOLVED THE ISSUE BY RECONNECTING THE SAME 15MM CONNECTOR BACK ONTO THE TUBE AND RESUMED VENTILATION. THE PATIENT HAD NO RETURN OF SPONTANEOUS CIRCULATION, BUT THE DEATH WAS NOT A RESULT OF A DEVICE MALFUNCTION.

    Patient problems: Cardiac Arrest; Insufficient Information

    MAUDE report 23956626 ↗
  • MalfunctionJan 5, 2026Disconnection

    IT WAS REPORTED THAT WHEN THE FIRST RESPONDERS ARRIVED ON THE SCENE, THE PATIENT WAS ALREADY IN CARDIAC ARREST, RESUSCITATION WAS INITIATED, AND THE PATIENT WAS INTUBATED AS A PART OF THE RESUSCITATIVE EFFORTS. THE ENDOTRACHEAL TUBE'S 15MM DISCONNECTED RIGHT AFTER THE INTUBATION PROCEDURE WAS PERFORMED AS THE STYLET WAS BEING REMOVED FROM THE TUBE. THE FIRST RESPONDER RESOLVED THE ISSUE BY RECONNECTING THE SAME 15MM CONNECTOR BACK ONTO THE TUBE AND RESUMED VENTILATION. THE PATIENT HAD NO RETURN OF SPONTANEOUS CIRCULATION, BUT THE DEATH WAS NOT A RESULT OF A DEVICE MALFUNCTION.

    Patient problems: Cardiac Arrest; Insufficient Information

    MAUDE report 23956604 ↗
  • MalfunctionAug 4, 2025Use of Device Problem; Use of Device Problem

    IT WAS REPORTED THAT DURING PRE-USAGE TESTING, A TRACH AND TWO ENDOTRACHEAL TUBE'S CUFF HAD AN INFLATION AND DEFLATION ISSUES. THERE WAS NO REPORTED PATIENT OUTCOME.

    Patient problems: Insufficient Information

    MAUDE report 22707118 ↗
  • MalfunctionAug 4, 2025Use of Device Problem; Use of Device Problem

    IT WAS REPORTED THAT DURING PRE-USAGE TESTING, A TRACH AND TWO ENDOTRACHEAL TUBE'S CUFF HAD AN INFLATION AND DEFLATION ISSUES. THERE WAS NO REPORTED PATIENT OUTCOME.

    Patient problems: Insufficient Information

    MAUDE report 22706803 ↗
  • InjuryFeb 19, 2025Gas/Air Leak; Gas/Air Leak

    IT WAS REPORTED THAT DURING THE TRACHEAL INTUBATION OF THE PATIENT, IT WAS FOUND THAT THE TUBE'S CUFF WAS LEAKING AND COULD NOT BE USED. THE DOCTOR URGENTLY REPLACED IT WITH THE NEW TRACHEAL TUBE FOR RESCUE. DURING THE EMERGENCY INTUBATION, THE INTUBATION TIME WAS DELAYED.

    Patient problems: Unintended Extubation

    MAUDE report 21410426 ↗
  • MalfunctionDec 11, 2024Material Separation; Material Separation

    IT WAS REPORTED THAT A TRACHEAL TUBE EXPERIENCED A CONNECTOR BREAK AT THE TRACHEAL TUBE INTERFACE, INDICATING PHYSICAL DAMAGE. THE ISSUE OCCURRED WITHIN A HOSPITAL SETTING. NO PATIENT WAS ASSOCIATED WITH THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20909932 ↗
  • MalfunctionDec 9, 2024Material Split, Cut or Torn; Material Split, Cut or Torn

    ACCORDING TO THE REPORTER, DURING PRE-USAGE INSPECTION, THE ENDOTRACHEAL TUBE SET WAS COMPLETELY BROKEN AND COULD NOT BE USED, SO IMMEDIATELY DISCARDED IT AND REPLACED IT WITH A NEW ONE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20880635 ↗
  • MalfunctionJun 11, 2024Obstruction of Flow; Gas/Air Leak; Obstruction of Flow; Gas/Air Leak

    ACCORDING TO THE REPORTER, DURING PATIENT USE, THE ENDOTRACHEAL TUBE'S CUFF HAD AN OBVIOUS AIR LEAKAGE. CHECKED THE CUFF INFLATION AGAIN AND FOUND THAT THE CUFF INFLATION WAS BLOCKED AND COULD NOT BE INFLATED. THEN, THE TUBE OF THE SAME MODEL AND SPECIFICATION WAS REPLACED, AND IT COULD BE USED NORMALLY AFTER REPLACEMENT.

    Patient problems: Unintended Extubation

    MAUDE report 19512997 ↗
  • MalfunctionSep 19, 2023Disconnection; Disconnection

    ACCORDING TO THE REPORTER, THE CONNECTOR TUBE WAS LOOSE AND EASILY DETACHES FROM THE ENDOTRACHEAL TUBE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17773746 ↗
  • MalfunctionApr 27, 2023Use of Device Problem; Material Split, Cut or Torn; Use of Device Problem; Material Split, Cut or Torn

    ACCORDING TO THE REPORTER, THERE WAS A HOLE NEAR THE BOUNDARY BETWEEN THE TUBE AND THE CUFF UPPER SUCTION TUBE. THERE WAS NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16827716 ↗
  • MalfunctionDec 1, 2020Use of Device Problem; Gas/Air Leak; Use of Device Problem; Gas/Air Leak

    ACCORDING TO THE REPORTER, THE DEVICE HAD AIR LEAKAGE WHICH OCCURRED DURING CUFF TESTING. WHEN SOAKED IN WATER AND VERIFIED, NO DAMAGE WAS FOUND ON THE CUFF ITSELF, AND IT WAS REPORTED THAT THE INFLATION LINE WAS DAMAGED. IT WAS REPORTED THAT THE LEAKAGE IS AROUND THE BASE OF THE TIP OF THE PILOT LINE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10924663 ↗
  • InjuryOct 31, 2020Use of Device Problem; Gas/Air Leak; Use of Device Problem; Gas/Air Leak

    ACCORDING TO THE REPORTER, DURING USE, THE DEVICE HAD MICRO LEAKS AND RUPTURED CUFF. THE PATIENT HAD A REPLACEMENT OF THE TUBE.

    Patient problems: Extubate

    MAUDE report 10767203 ↗

Other Tube, tracheal (w/wo connector) devices

All Tube, tracheal (w/wo connector) devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.